Diagnostic Accuracy of Loop-Mediated Isothermal Amplification (TB-LAMP) for Tuberculosis in Children

被引:6
|
作者
Promsena, Pathariya [1 ,2 ]
Jantarabenjakul, Watsamon [1 ,2 ,3 ]
Suntarattiwong, Piyarat [4 ]
Sudjaritruk, Tavitiya [5 ]
Anugulruengkitt, Suvaporn [1 ,2 ]
Rotcheewaphan, Suwatchareeporn [6 ,7 ]
Petsong, Suthidee [6 ]
Sawangsinth, Panadda [2 ]
Sophonphan, Jiratchaya [2 ]
Tawan, Monta [2 ]
Moonwong, Juthamanee [2 ]
Puthanakit, Thanyawee [1 ,2 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Pediat, Rama 4 Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Med, Ctr Excellence Pediat Infect Dis & Vaccines, Bangkok, Thailand
[3] King Chulalongkorn Mem Hosp, Thai Red Cross Emerging Infect Dis Clin Ctr, Bangkok, Thailand
[4] Queen Sirikit Natl Inst Child Hlth, Pediat Infect Dis Unit, Bangkok, Thailand
[5] Chiang Mai Univ, Fac Med, Dept Pediat, Chiang Mai, Thailand
[6] Chulalongkorn Univ, Fac Med, Dept Microbiol, Bangkok, Thailand
[7] Chulalongkorn Univ, Fac Med, Dept Med, TB Res Unit, Bangkok, Thailand
关键词
molecular diagnosis; pediatric tuberculosis; point-of-care; TB culture; TB-LAMP; MYCOBACTERIUM-TUBERCULOSIS; PULMONARY TUBERCULOSIS; ASSAY;
D O I
10.1093/jpids/piab097
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background Diagnosing tuberculosis (TB) in children is challenging due to its paucibacillary nature. Loop-mediated isothermal amplification (TB-LAMP) is a simple, rapid, and specific point-of-care molecular diagnostic test. However, evaluation of its performance remains limited in children. This study aimed to evaluate the diagnostic performance of Eiken TB-LAMP among children with presumed tuberculosis disease. Methods Pulmonary and extrapulmonary specimens were collected from children under 18 years with presumed TB. Each specimen was tested by using TB-LAMP, acid-fast bacilli (AFB) smear microscopy, and one of the two molecular assays (polymerase chain reaction [PCR] or Xpert MTB/RIF). Sensitivity and specificity were estimated compared to mycobacterial culture as reference standard. Results From January 2020 to January 2021, 75 participants with presumed TB were enrolled with median age of 7 years (IQR 2-12). Seventeen specimens from 16 (21.3%) children had bacteriologically confirmed TB: 10 pulmonary and 7 extrapulmonary specimens. Overall sensitivity and specificity of TB-LAMP was 76.5% (95% CI 50.1%-93.2%) and 100% (95% CI 94.3%-100%), respectively. It had significantly higher sensitivity than AFB (52.9%, 95% CI 27.8%-77.0%) and similar to other molecular assays; PCR 82.4% (95% CI 56.6%-96.2%), Xpert MTB/RIF 70.0% (95% CI 34.8%-93.3%). Sensitivity of TB-LAMP for pulmonary, lymph node tissue, and extrapulmonary fluid was 80% (95% CI 44.4%-97.5%), 100% (95% CI 39.8-100), and 33.3% (95% CI 0.8-90.6), respectively. TB-LAMP detected all smear-positive (N = 9) and 50% of smear-negative (N = 8) specimens. Conclusions TB-LAMP had higher sensitivity than AFB microscopy and accuracy similar to other molecular assays in both pulmonary and extrapulmonary specimens. These findings support using TB-LAMP as a point-of-care test in children.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [41] Rapid detection of Salmonella Typhi by loop-mediated isothermal amplification (LAMP) method
    Abdullah, J.
    Saffie, N.
    Sjasri, F. A. R.
    Husin, A.
    Abdul-Rahman, Z.
    Ismail, A.
    Aziah, I.
    Mohamed, M.
    BRAZILIAN JOURNAL OF MICROBIOLOGY, 2014, 45 (04) : 1385 - 1391
  • [42] Rapid and Sensitive Diagnosis of Cattle Anaplasmosis by Loop-Mediated Isothermal Amplification (LAMP)
    Wen, Xiao-Bo
    Jiang, Hui-Ting
    Zhang, Yang-Long
    Lang, Xiu-Yan
    Liu, Jiao
    Ni, Hong-Bo
    PAKISTAN VETERINARY JOURNAL, 2016, 36 (02) : 174 - 178
  • [43] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [44] Evaluating the use of loop-mediated isothermal amplification (LAMP) method for detection of Mycobacterium tuberculosis in Indonesian clinical isolates
    Lisdawati, Vivi
    Oshibe, Tomohiro
    Tsuji, Hidetaka
    Sudiro, Tjahjani M.
    Adianti, Myrna
    Sukarso, Triyani
    Arief, Holy
    Hotta, Hak
    Sudarmono, Pratiwi
    MEDICAL JOURNAL OF INDONESIA, 2012, 21 (04) : 188 - 195
  • [45] Sub-microliter scale in-gel loop-mediated isothermal amplification (LAMP) for detection of Mycobacterium tuberculosis
    Dammika P. Manage
    Linda Chui
    Linda M. Pilarski
    Microfluidics and Nanofluidics, 2013, 14 : 731 - 741
  • [46] Loop-mediated isothermal amplification (LAMP): Expansion of its practical application as a tool to achieve universal health coverage
    Mori, Yasuyoshi
    Notomi, Tsugunori
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2020, 26 (01) : 13 - 17
  • [47] Loop-Mediated Isothermal Amplification (LAMP): Potential Point-of-Care Testing for Vulvovaginal Candidiasis
    Li, Meng
    Jin, Xiangyu
    Jiang, Qingyun
    Wei, Hongbo
    Deng, Anni
    Mao, Zeyin
    Wang, Ying
    Zeng, Zhen
    Wu, Yifan
    Liu, Shuai
    Kim, Juhyun
    Wang, Xiaoqian
    Liu, Ying
    Liu, Jun
    Lv, Wenqi
    Huang, Leyang
    Liao, Qinping
    Huang, Guoliang
    Zhang, Lei
    JOURNAL OF FUNGI, 2023, 9 (12)
  • [48] Loop-Mediated Isothermal Amplification (LAMP): Methods for Plant Species Identification in Food
    Focke, Felix
    Haase, Ilka
    Fischer, Markus
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (12) : 2943 - 2949
  • [49] Loop-mediated isothermal amplification (LAMP): a rapid, accurate, and cost-effective diagnostic method for infectious diseases
    Mori, Yasuyoshi
    Notomi, Tsugunori
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2009, 15 (02) : 62 - 69
  • [50] Loop-Mediated Isothermal Amplification (LAMP) as a Promising Point-of-Care Diagnostic Strategy in Avian Virus Research
    Padzil, Faiz
    Mariatulqabtiah, Abdul Razak
    Tan, Wen Siang
    Ho, Kok Lian
    Isa, Nurulfiza Mat
    Lau, Han Yih
    Abu, Jalila
    Chuang, Kuo-Pin
    ANIMALS, 2022, 12 (01):