Diagnostic Accuracy of Loop-Mediated Isothermal Amplification (TB-LAMP) for Tuberculosis in Children

被引:6
|
作者
Promsena, Pathariya [1 ,2 ]
Jantarabenjakul, Watsamon [1 ,2 ,3 ]
Suntarattiwong, Piyarat [4 ]
Sudjaritruk, Tavitiya [5 ]
Anugulruengkitt, Suvaporn [1 ,2 ]
Rotcheewaphan, Suwatchareeporn [6 ,7 ]
Petsong, Suthidee [6 ]
Sawangsinth, Panadda [2 ]
Sophonphan, Jiratchaya [2 ]
Tawan, Monta [2 ]
Moonwong, Juthamanee [2 ]
Puthanakit, Thanyawee [1 ,2 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Pediat, Rama 4 Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Med, Ctr Excellence Pediat Infect Dis & Vaccines, Bangkok, Thailand
[3] King Chulalongkorn Mem Hosp, Thai Red Cross Emerging Infect Dis Clin Ctr, Bangkok, Thailand
[4] Queen Sirikit Natl Inst Child Hlth, Pediat Infect Dis Unit, Bangkok, Thailand
[5] Chiang Mai Univ, Fac Med, Dept Pediat, Chiang Mai, Thailand
[6] Chulalongkorn Univ, Fac Med, Dept Microbiol, Bangkok, Thailand
[7] Chulalongkorn Univ, Fac Med, Dept Med, TB Res Unit, Bangkok, Thailand
关键词
molecular diagnosis; pediatric tuberculosis; point-of-care; TB culture; TB-LAMP; MYCOBACTERIUM-TUBERCULOSIS; PULMONARY TUBERCULOSIS; ASSAY;
D O I
10.1093/jpids/piab097
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background Diagnosing tuberculosis (TB) in children is challenging due to its paucibacillary nature. Loop-mediated isothermal amplification (TB-LAMP) is a simple, rapid, and specific point-of-care molecular diagnostic test. However, evaluation of its performance remains limited in children. This study aimed to evaluate the diagnostic performance of Eiken TB-LAMP among children with presumed tuberculosis disease. Methods Pulmonary and extrapulmonary specimens were collected from children under 18 years with presumed TB. Each specimen was tested by using TB-LAMP, acid-fast bacilli (AFB) smear microscopy, and one of the two molecular assays (polymerase chain reaction [PCR] or Xpert MTB/RIF). Sensitivity and specificity were estimated compared to mycobacterial culture as reference standard. Results From January 2020 to January 2021, 75 participants with presumed TB were enrolled with median age of 7 years (IQR 2-12). Seventeen specimens from 16 (21.3%) children had bacteriologically confirmed TB: 10 pulmonary and 7 extrapulmonary specimens. Overall sensitivity and specificity of TB-LAMP was 76.5% (95% CI 50.1%-93.2%) and 100% (95% CI 94.3%-100%), respectively. It had significantly higher sensitivity than AFB (52.9%, 95% CI 27.8%-77.0%) and similar to other molecular assays; PCR 82.4% (95% CI 56.6%-96.2%), Xpert MTB/RIF 70.0% (95% CI 34.8%-93.3%). Sensitivity of TB-LAMP for pulmonary, lymph node tissue, and extrapulmonary fluid was 80% (95% CI 44.4%-97.5%), 100% (95% CI 39.8-100), and 33.3% (95% CI 0.8-90.6), respectively. TB-LAMP detected all smear-positive (N = 9) and 50% of smear-negative (N = 8) specimens. Conclusions TB-LAMP had higher sensitivity than AFB microscopy and accuracy similar to other molecular assays in both pulmonary and extrapulmonary specimens. These findings support using TB-LAMP as a point-of-care test in children.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [31] Comparative Evaluation of the Loop-Mediated Isothermal Amplification Assay for Detecting Pulmonary Tuberculosis
    Kim, Chang-Ki
    Cho, Eun A.
    Shin, Dong Mi
    Choi, Sung Won
    Shin, So Youn
    ANNALS OF LABORATORY MEDICINE, 2018, 38 (02) : 119 - 124
  • [32] Diagnostic Yield of Oral Swab Testing by TB-LAMP for Diagnosis of Pulmonary Tuberculosis
    Song, Yanhua
    Ma, Yifeng
    Liu, Rongmei
    Shang, Yuanyuan
    Ma, Liping
    Huo, Fengmin
    Li, Yunxu
    Shu, Wei
    Wang, Yufeng
    Gao, Mengqiu
    Pang, Yu
    INFECTION AND DRUG RESISTANCE, 2021, 14 : 89 - 95
  • [33] Loop-mediated isothermal amplification (LAMP) test for diagnosis of uncomplicated malaria in endemic areas: a meta-analysis of diagnostic test accuracy
    Selvarajah, Denesh
    Naing, Cho
    Htet, Norah Htet
    Mak, Joon Wah
    MALARIA JOURNAL, 2020, 19 (01)
  • [34] Loop-mediated isothermal amplification (LAMP) for the identification of invasive Aedes mosquito species
    Schenkel, C. D.
    Kamber, T.
    Schaffner, F.
    Mathis, A.
    Silaghi, C.
    MEDICAL AND VETERINARY ENTOMOLOGY, 2019, 33 (03) : 345 - 351
  • [35] Current loop-mediated isothermal amplification (LAMP) technologies for the detection of poultry pathogens
    Ehtisham-Ul-Haque, S.
    Zaman, M. A.
    Kiran, M.
    Rafique, M. K.
    Qamar, M. F.
    Younus, M.
    WORLDS POULTRY SCIENCE JOURNAL, 2018, 74 (02) : 287 - 300
  • [36] The Development of a Loop-Mediated Isothermal Amplification Method (LAMP) for Echinococcus granulosis Coprodetection
    Salant, Harold
    Abbasi, Ibrahim
    Hamburger, Joseph
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2012, 87 (05) : 883 - 887
  • [37] Evaluation of the diagnostic value of loop-mediated isothermal amplification assays targeting three different Mycobacterium tuberculosis genes
    Guo, Yan-Ling
    Wang, Sai-Sai
    Jiang, Guang-Lu
    Ban, Wu-Juan
    Liu, Yang
    JOURNAL OF MICROBIOLOGICAL METHODS, 2022, 200
  • [38] Development of loop-mediated isothermal amplification (LAMP) for simple detection of Leishmania infection
    Sriworarat, Chaichontat
    Phumee, Atchara
    Mungthin, Mathirut
    Leelayoova, Saovanee
    Siriyasatien, Padet
    PARASITES & VECTORS, 2015, 8
  • [39] A novel thermostable polymerase for RNA and DNA loop-mediated isothermal amplification (LAMP)
    Chander, Yogesh
    Koelbl, Jim
    Puckett, Jamie
    Moser, Michael J.
    Klingele, Audrey J.
    Liles, Mark R.
    Carrias, Abel
    Mead, David A.
    Schoenfeld, Thomas W.
    FRONTIERS IN MICROBIOLOGY, 2014, 5
  • [40] LampPort: a handheld digital microfluidic device for loop-mediated isothermal amplification (LAMP)
    Wan, Liang
    Gao, Jie
    Chen, Tianlan
    Dong, Cheng
    Li, Haoran
    Wen, Yan-Zi
    Lun, Zhao-Rong
    Jia, Yanwei
    Mak, Pui-In
    Martins, Rui P.
    BIOMEDICAL MICRODEVICES, 2019, 21 (01)