共 50 条
Analysis of twenty phenolic compounds in human urine: hydrochloric acid hydrolysis, solid-phase extraction based on K2CO3-treated silica, and gas chromatography tandem mass spectrometry
被引:49
|作者:
Lu, Dasheng
[1
,2
]
Feng, Chao
[2
]
Wang, Dongli
[3
]
Lin, Yuanjie
[2
]
Ip, Ho Sai Simon
[3
]
She, Jianwen
[3
]
Xu, Qian
[2
]
Wu, Chunhua
[1
]
Wang, Guoquan
[2
]
Zhou, Zhijun
[1
]
机构:
[1] Fudan Univ, Sch Publ Hlth, MOE Key Lab Publ Hlth, Shanghai 200032, Peoples R China
[2] Shanghai Municipal Ctr Dis Control & Prevent, Shanghai 200336, Peoples R China
[3] Calif Dept Publ Hlth, Environm Hlth Lab Branch, Richmond, CA 94804 USA
关键词:
EDCs;
LVI-GC-MS-MS;
Phenolic biomarker;
Human biomonitoring;
Acid hydrolysis;
K2CO3-treated-silica-gel SPE;
9 ENVIRONMENTAL PHENOLS;
A DIGLYCIDYL ETHERS;
HPLC-MS/MS METHOD;
BISPHENOL-A;
ULTRAVIOLET FILTERS;
METABOLITES;
PARABENS;
QUANTIFICATION;
TRICLOSAN;
CHILDREN;
D O I:
10.1007/s00216-015-8598-1
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
This study developed a new method for the analysis of 20 phenolic compounds in human urine. The urine samples were prepared by hydrochloric acid (HCl) hydrolysis, liquid-liquid extraction (LLE), and solid-phase extraction (SPE) cleanup. We found that HCl hydrolysis is of similar effectiveness to, and much cheaper than, the traditional enzymatic method. Vanillic acid was co-eluted with butyl paraben and interfered with the determination of butyl paraben in urine. K2CO3-treated-silica-gel SPE was designed to efficiently eliminate interference from the endogenous organic acids (especially vanillic acid) in urine. After derivatization, the samples were analyzed by large-volume-injection gas chromatography-tandem mass spectrometry (LVI-GC-MS-MS). Good linearity (R (2) a parts per thousand yenaEuro parts per thousand 0.996) was established in the range 0.1-100 ng mL(-1) for all analytes. Method detection limits (MDLs) were 0.7-9.8 pg mL(-1). Intraday (n = 5) and interday (n = 5 days) validation was performed, with satisfactory accuracy (recovery: 70-126 % and 73-107 %, respectively) and precision (RSD a parts per thousand currency signaEuro parts per thousand 19 %) at two levels (low: 0.1 and 0.5 ng mL(-1); high: 5 and 10 ng mL(-1)). The method was used in a population study and achieved more than 85 % detection for most analytes; mean analyte concentrations were in the range 0.01-185 ng mL(-1). The method is suitable for the analysis of multiple phenolic metabolites in human urine.
引用
收藏
页码:4131 / 4141
页数:11
相关论文