An evaluation of resonance frequency analysis for the determination of the primary stability of orthodontic palatal implants. A study in human cadavers

被引:58
|
作者
Gedrange, T
Hietschold, V
Mai, R
Wolf, P
Nicklisch, M
Harzer, W
机构
[1] Tech Univ Dresden, Dept Orthodont, D-8027 Dresden, Germany
[2] Tech Univ Dresden, Dept Radiol, D-8027 Dresden, Germany
[3] Tech Univ Dresden, Dept Maxillofacial Surg, D-8027 Dresden, Germany
[4] Tech Univ Dresden, Inst Anat, D-8027 Dresden, Germany
关键词
orthodontic implant; palatal suture; paramedially; primary stability;
D O I
10.1111/j.1600-0501.2005.01134.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The primary stability of short orthodontic implants is important for anchorage. Methods: For this study 14 cadaveric human heads were used. The stability of orthodontic implants (Straumann) with lengths of 4 and 6 mm and different localization (palatal suture or paramedially) were evaluated. The implants with length of 6 mm were only placed in the suture and primary stability was non-invasively determined with the resonance frequency (Osstell((R))). The invasive method for the analysis of the morphometric parameters of the implant/bone contact was carried out by means of histological and radiological examinations. Results: The 6 mm implants have significant better primary stability in the palatal suture as 4 mm implants paramedially (P < 0.05). No differences were found between 6 and 4 mm implants in the palatal suture and between 4 mm implants in palatal suture to paramedially. The histological and radiological results demonstrate the ability to measure the implant stability by investigation of the bone offer and density around the implant. Bone structure, especially the pore size in the trabecular bone and the precision of placement may influence the stability. Conclusion: This study shows that the short implant gives sufficient bone fixation, independently of placement. The quality of implantation and bone structure are more important than the length of the orthodontic implant.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 27 条
  • [21] Insertion Torque, Removal Torque, and Resonance Frequency Analysis Values of Ultrashort, Short, and Standard Dental Implants: An In Vitro Study on Polyurethane Foam Sheets
    Comuzzi, Luca
    Tumedei, Margherita
    Romasco, Tea
    Petrini, Morena
    Afrashtehfar, Kelvin I.
    Inchingolo, Francesco
    Piattelli, Adriano
    Di Pietro, Natalia
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (01)
  • [22] Evaluation of local cancellous bone amelioration by poly-L-DL-lactide copolymers to improve primary stability of dental implants: a biomechanical study in sheep
    Stuebinger, Stefan
    Waser, Jasmin
    Hefti, Thomas
    Drechsler, Anika
    Sidler, Michele
    Klein, Karina
    von Rechenberg, Brigitte
    Schlottig, Falko
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (05) : 572 - 580
  • [23] An In Vitro Evaluation, on Polyurethane Foam Sheets, of the Insertion Torque (IT) Values, Pull-Out Torque Values, and Resonance Frequency Analysis (RFA) of NanoShort Dental Implants
    Comuzzi, Luca
    Iezzi, Giovanna
    Piattelli, Adriano
    Tumedei, Margherita
    POLYMERS, 2019, 11 (06)
  • [24] The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study
    Mikic, Mirko
    Vlahovic, Zoran
    Stevanovic, Momir
    Arsic, Zoran
    Mladenovic, Rasa
    TOMOGRAPHY, 2022, 8 (03) : 1293 - 1306
  • [25] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis—an animal study
    Jacek Matys
    Rafał Flieger
    Gianluca Tenore
    Kinga Grzech-Leśniak
    Umberto Romeo
    Marzena Dominiak
    Lasers in Medical Science, 2018, 33 : 489 - 495
  • [26] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study
    Matys, Jacek
    Flieger, Rafa
    Tenore, Gianluca
    Grzech-Lesniak, Kinga
    Romeo, Umberto
    Dominiak, Marzena
    LASERS IN MEDICAL SCIENCE, 2018, 33 (03) : 489 - 495