An evaluation of resonance frequency analysis for the determination of the primary stability of orthodontic palatal implants. A study in human cadavers

被引:58
|
作者
Gedrange, T
Hietschold, V
Mai, R
Wolf, P
Nicklisch, M
Harzer, W
机构
[1] Tech Univ Dresden, Dept Orthodont, D-8027 Dresden, Germany
[2] Tech Univ Dresden, Dept Radiol, D-8027 Dresden, Germany
[3] Tech Univ Dresden, Dept Maxillofacial Surg, D-8027 Dresden, Germany
[4] Tech Univ Dresden, Inst Anat, D-8027 Dresden, Germany
关键词
orthodontic implant; palatal suture; paramedially; primary stability;
D O I
10.1111/j.1600-0501.2005.01134.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The primary stability of short orthodontic implants is important for anchorage. Methods: For this study 14 cadaveric human heads were used. The stability of orthodontic implants (Straumann) with lengths of 4 and 6 mm and different localization (palatal suture or paramedially) were evaluated. The implants with length of 6 mm were only placed in the suture and primary stability was non-invasively determined with the resonance frequency (Osstell((R))). The invasive method for the analysis of the morphometric parameters of the implant/bone contact was carried out by means of histological and radiological examinations. Results: The 6 mm implants have significant better primary stability in the palatal suture as 4 mm implants paramedially (P < 0.05). No differences were found between 6 and 4 mm implants in the palatal suture and between 4 mm implants in palatal suture to paramedially. The histological and radiological results demonstrate the ability to measure the implant stability by investigation of the bone offer and density around the implant. Bone structure, especially the pore size in the trabecular bone and the precision of placement may influence the stability. Conclusion: This study shows that the short implant gives sufficient bone fixation, independently of placement. The quality of implantation and bone structure are more important than the length of the orthodontic implant.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 27 条
  • [1] Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque
    Sciasci, Plinio
    Casalle, Nicole
    Vaz, Luis Geraldo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (03) : 274 - 279
  • [2] Is Resonance Frequency Analysis a Reliable Evaluation for Primary Stability of Implants Without Apical Contact?
    Ozyurt, Anil
    Bilmenoglu, Caglar
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (03) : 543 - 548
  • [3] Measurement of Primary Stability of Mini Implants Using Resonance Frequency Analysis
    Singh, Ashish Kumar
    Kannan, Sridhar
    Arora, Nitin
    Bajaj, Yatin
    Revankar, Ameet V.
    APOS TRENDS IN ORTHODONTICS, 2018, 8 (03) : 139 - 145
  • [4] An in vitro study of factors affecting the primary stability of orthodontic mini-implants
    Holm, Lindsy
    Cunningham, Susan J.
    Petrie, Aviva
    Cousley, Richard R. J.
    ANGLE ORTHODONTIST, 2012, 82 (06) : 1022 - 1028
  • [5] Predicting osseointegration by means of implant primary stability - A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants
    Nedir, R
    Bischof, M
    Szmukler-Moncler, S
    Bernard, JP
    Samson, J
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) : 520 - 528
  • [6] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Annette Rabel
    Steffen Gerhard Köhler
    Andrea Maria Schmidt-Westhausen
    Clinical Oral Investigations, 2007, 11 : 257 - 265
  • [7] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Rabel, Annette
    Koehler, Steffen Gerhard
    Schmidt-Westhausen, Andrea Maria
    CLINICAL ORAL INVESTIGATIONS, 2007, 11 (03) : 257 - 265
  • [8] The association between thread pitch and cortical bone thickness influences the primary stability of orthodontic miniscrew implants: a study in human cadaver palates
    Budsabong, Chalermporn
    Trachoo, Vorapat
    Pittayapat, Pisha
    Chantarawaratit, Pintu-On
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2022, 11 (02) : 68 - 73
  • [9] The Influence of the Diameter of Orthodontic Mini-Implants on Primary Stability: Bending Tests-An In Vitro Study
    Sousa-Santos, Catarina
    Sousa-Santos, Sofia
    Mendes, Joana
    Coelho, Carlos
    Aroso, Carlos
    Sousa-Santos, Primavera
    Mendes, Jose Manuel
    MATERIALS, 2024, 17 (13)
  • [10] Evaluation of Cortical Bone Microdamage and Primary Stability of Orthodontic Miniscrew Using a Human Bone Analogue
    Teekavanich, Chutimont
    Uezono, Masayoshi
    Takakuda, Kazuo
    Ogasawara, Takeshi
    Techalertpaisarn, Paiboon
    Moriyama, Keiji
    MATERIALS, 2021, 14 (08)