A multiplexed three-dimensional paper-based electrochemical impedance device for simultaneous label-free affinity sensing of total and glycated haemoglobin: The potential of using a specific single-frequency value for analysis

被引:39
作者
Boonyasit, Yuwadee [1 ]
Chailapakul, Orawon [2 ]
Laiwattanapaisal, Wanida [3 ]
机构
[1] Chulalongkorn Univ, Fac Allied Hlth Sci, Grad Program Clin Biochem & Mol Med, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Dept Chem, EOSRU, Fac Sci, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Bangkok 10330, Thailand
关键词
Glycated haemoglobin; Three-dimensional paper-based electrochemical impedance device; 3-Aminophenylboronic acid; Haptoglobin; Eggshell membrane; Label-free electrochemical detection; IFCC REFERENCE METHOD; ENZYME SENSOR; FRUCTOSYL-VALINE; ION-EXCHANGE; HBA(1C); IMMUNODEVICE; BLOOD; IMMUNOASSAY; BIOSENSOR; ELECTRODE;
D O I
10.1016/j.aca.2016.05.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel three-dimensional paper-based electrochemical impedance device (3D-PEID) is first introduced for measuring multiple diabetes markers. Herein, a simple 3D-PEID composed of a dual screen-printed electrode on wax-patterned paper coupled with a multilayer of magnetic paper was fabricated for label-free electrochemical detection. The results clearly demonstrated in a step-wise manner that the haptoglobin (Hp)-modified and 3-aminophenylboronic acid (APBA)-modified eggshell membranes (ESMs) were highly responsive to a clinically relevant range of total (0.5-20 g dL(-1); r(2) = 0.989) and glycated haemoglobin (HbA1c) (2.3%-14%; r(2) = 0.997) levels with detection limits (S/N = 3) of 0.08 g dL(-1) and 0.21%, respectively. The optimal binding frequencies of total haemoglobin and HbA1c to their specific recognition elements were 5.18 Hz and 9.99 Hz, respectively. The within-run coefficients of variation (CV) were 1.84%, 2.18%, 1.72%, and 2.01%, whereas the run-to-run CVs were 2.11%, 2.41%, 2.08%, and 2.21%, when assaying two levels of haemoglobin and HbA1c, respectively. The CVs for the haemoglobin and HbA1c levels measured on ten independently fabricated paper-based sheets were 1.96% and 2.10%, respectively. These results demonstrated that our proposed system achieved excellent precision for the simultaneous detection of total haemoglobin and HbA1c, with an acceptable reproducibility of fabrication. The long-term stability of the Hp-modified eggshell membrane (ESM) was 98.84% over a shelf-life of 4 weeks, enabling the possibility of storage or long-distance transport to remote regions, particularly in resource-limited settings; however, for the APBA-modified ESM, the stability was 92.35% over a one-week period. Compared with the commercial automated method, the results demonstrated excellent agreement between the techniques (p-value < 0.05), thus permitting the potential application of 3D-PEID for the monitoring of the glycaemic status in diabetic patients. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 66 条
[1]   Chemiluminescent acridinium-9-carboxamide boronic acid probes: Application to a homogenous glycated hemoglobin assay [J].
Adamczyk, M ;
Chen, YY ;
Johnson, DD ;
Mattingly, PG ;
Moore, JA ;
Pan, Y ;
Reddy, RE .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2006, 16 (05) :1324-1328
[2]  
Adamson Teagan L, 2014, J Diabetes Sci Technol, V8, P350
[3]   The promise of electrochemical impedance spectroscopy as novel technology for the management of patients with diabetes mellitus [J].
Adamson, Teagan Leigh ;
Eusebio, Francis Ang ;
Cook, Curtiss B. ;
LaBelle, Jeffrey T. .
ANALYST, 2012, 137 (18) :4179-4187
[4]  
Boonyasit Y., 2015, ANAL BIOANAL CHEM, P1
[5]   A microfluidic paper-based analytical device for the assay of albumin-corrected fructosamine values from whole blood samples [J].
Boonyasit, Yuwadee ;
Laiwattanapaisal, Wanida .
BIOANALYSIS, 2015, 7 (01) :79-90
[6]  
Bry L, 2001, CLIN CHEM, V47, P153
[7]   Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics [J].
Carrilho, Emanuel ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7091-7095
[8]   Detection of Total and A1c-Glycosylated Hemoglobin in Human Whole Blood Using Sandwich Immunoassays on Polydimethylsiloxane-Based Antibody Microarrays [J].
Chen, Huang-Han ;
Wu, Chih-Hsing ;
Tsai, Mei-Ling ;
Huang, Yi-Jing ;
Chen, Shu-Hui .
ANALYTICAL CHEMISTRY, 2012, 84 (20) :8635-8641
[9]   Detection of glycated hemoglobin (HbA1c) based on impedance measurement with parallel electrodes integrated into a microfluidic device [J].
Chuang, Ya-Chun ;
Lan, Kung-Chieh ;
Hsieh, Ku-Meng ;
Jang, Ling-Sheng ;
Chen, Ming-Kun .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 :1222-1230
[10]   Consensus statement on the worldwide standardisation of the HbA1c measurement [J].
Committee, Consensus .
DIABETOLOGIA, 2007, 50 (10) :2042-2043