Techno-economic analysis of energy storage devices for microgrid?s ramp rate control using bi-level evaluation method

被引:8
作者
Tahir, Hira [1 ]
Gelani, Hasan Erteza [1 ]
Idrees, Zeba [2 ]
Kim, Rae -Young [3 ]
机构
[1] Univ Engn & Technol, Dept Energy Engn, New Campus, Kala Shah Kaku 39020, Pakistan
[2] Univ Engn & Technol, Dept Elect Engn, Lahore 54890, Pakistan
[3] Hanyang Univ, Dept Elect & Biomed Engn, Seoul 04763, South Korea
关键词
Energy storage device; Microgrid; Optimization; Ramp rate; Renewable energy resources; Techno-economic analysis; WIND POWER; PHOTOVOLTAIC PV; BATTERY STORAGE; SYSTEM; MANAGEMENT; ALGORITHM; FLUCTUATIONS; TECHNOLOGIES; OPERATION; IMPACT;
D O I
10.1016/j.est.2022.105745
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Recently, energy storage devices (ESDs) have been widely deployed to alleviate high ramp rates in microgrids (MGs), thereby enabling the large-scale penetration of renewable energy resources (RERs) into utility grids. However, there is a lack of general guidelines to assist design engineers promptly evaluate the techno-economic benefits of ESDs under various RERs, RERs-load demand combinations and different ESD combinations. A bi-level evaluation method is devised in this study to assess the techno-economic feasibility of deploying ESDs to control the ramp rate of an MG, and comprehensive case studies are performed to answer the following ques-tions: (i) How do the fluctuations in a single RER, hybrid RERs, and a hybrid RERs-load demand combination influence the techno-economic aspects of ESD?, (ii) What type of ESD should be considered to obtain the best techno-economic benefits? The results suggest that the total energy storage requirements for ramp rate control of the MG can be lowered by hybridizing the RERs at a specific location. Specifically, the power and energy ca-pacities can be reduced by up to 19.4 % and 57.6 %, respectively. The results also revealed that failing to account for fluctuations in load demand when calculating the ESD capacity may result in an underestimation of the power and energy capacities of 7.6 % and 14.3 %, respectively. Regarding the type of ESD, lead-acid batteries were found to be the most expensive option to alleviate the ramp rate of the MG. The results indicated that lithium-ion batteries are the most cost-effective option compared with other types of sole/hybrid combinations. Moreover, it was determined that the initial investment cost and lifetime of the ESD are critical factors in selecting the most suitable ESD/ hybrid ESD for ramp rate control of a MG. In addition, the results demonstrated that hybrid combinations are only economical for stricter ramp rate constraints.
引用
收藏
页数:13
相关论文
共 25 条
  • [1] Bi-level decision making in techno-economic planning and probabilistic analysis of community based sector-coupled energy system
    Kumar, Nishant
    Namrata, Kumari
    Samadhiya, Akshit
    APPLIED INTELLIGENCE, 2023, 53 (06) : 6604 - 6628
  • [2] Techno-economic analysis of metal hydride-based energy storage system in microgrid
    Kumar, Kuldeep
    Alam, Mohd
    Dutta, Viresh
    ENERGY STORAGE, 2019, 1 (03)
  • [3] Cross-climate analysis of techno-economic metrics in bi-level electrical and hydrogen storage systems for off-grid electrification of buildings
    Jahanbin, Aminhossein
    Abdolmaleki, Leila
    Berardi, Umberto
    JOURNAL OF ENERGY STORAGE, 2025, 107
  • [4] Thermal energy storage using phase change materials: Techno-economic evaluation of a cold storage installation in an office building
    Tan, Pepe
    Lindberg, Patrik
    Eichler, Kaia
    Loveryd, Per
    Johansson, Par
    Kalagasidis, Angela Sasic
    APPLIED ENERGY, 2020, 276
  • [5] Comparative techno-economic analysis of using multisource renewable energy with flexible storage systems for various environments
    Hoseinzadeh, Siamak
    Pourfayaz, Fathollah
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2025,
  • [6] Techno-Economic Analysis of Using Reversible Turbomachinery for Pumped Thermal Energy Storage Systems
    Parisi, Simone
    Desai, Nishith B.
    Haglind, Fredrik
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (05):
  • [7] Ramp Rate Control of Photovoltaic Power Plant Output Using Energy Storage Devices
    Salehi, Vahid
    Radibratovic, Brian
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [8] Dynamic modelling and techno-economic analysis of adiabatic compressed air energy storage for emergency back-up power in supporting microgrid
    Li, Yaowang
    Miao, Shihong
    Luo, Xing
    Yin, Binxin
    Han, Ji
    Wang, Jihong
    APPLIED ENERGY, 2020, 261
  • [9] Driving to the future of energy storage: Techno-economic analysis of a novel method to recondition second life electric vehicle batteries
    Horesh, Noah
    Quinn, Casey
    Wang, Hongjie
    Zane, Regan
    Ferry, Mike
    Tong, Shijie
    Quinn, Jason C.
    APPLIED ENERGY, 2021, 295
  • [10] Optimal Techno-Economic Unit Sizing of Hybrid PV/Wind/Battery Energy System for an Islanded Microgrid Using the Forever Power Method
    Alalwani, Sami H.
    2015 SAUDI ARABIA SMART GRID CONFERENCE (SASG), 2015,