The aim of this study was to evaluate the first 100 cementless ceramic-on-ceramic total hip arthroplasty (THA) performed at our institution with more than nine years of follow-up. Clinical evaluation was performed using Harris hip score. Radiological evaluation was performed by two surgeons. Four patients were lost to follow-up. Harris hip score significantly improved at latest follow-up. Radiological analysis showed calcar osteolysis for 75 patients and one cup loosening. One patient required a revision five years postoperatively for cup loosening. Based on these results and the routine use of a navigation system to optimise positioning of the implants, we advocate the use of uncemented hydroxyapatite coated ceramic-on-ceramic THA in young and active patients in our current practice.
引用
收藏
页码:1599 / 1604
页数:6
相关论文
共 27 条
[1]   Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study [J].
Bascarevic, Zoran ;
Vukasinovic, Zoran ;
Slavkovic, Nemanja ;
Dulic, Borislav ;
Trajkovic, Goran ;
Bascarevic, Violeta ;
Timotijevic, Sladjan .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) :1129-1135
[2]   Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years - A six- to 11-year evaluation [J].
Bizot, P ;
Hannouche, D ;
Nizard, R ;
Witvoet, J ;
Sedel, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (02) :190-194
[3]  
Boutin P, 2000, CLIN ORTHOP RELAT R, P4
[4]  
CHARNLEY J, 1970, CLIN ORTHOP RELAT R, P7
[5]  
CHARNLEY J, 1975, CLIN ORTHOP RELAT R, P170
[6]   The 2009 Frank Stinchfield Award "Hip Squeaking'' A Biomechanical Study of Ceramic-on-ceramic Bearing Surfaces [J].
Chevillotte, Christophe ;
Trousdale, Robert T. ;
Chen, Qingshan ;
Guyen, Olivier ;
An, Kai-Nan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :345-350
[7]   LONG-TERM (12 TO 18-YEAR) FOLLOW-UP OF CEMENTED TOTAL HIP REPLACEMENTS IN PATIENTS WHO WERE LESS THAN 50 YEARS OLD - A FOLLOW-UP NOTE [J].
COLLIS, DK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (04) :593-597
[8]  
D'Antonio J, 2003, ORTHOPEDICS, V26, P39
[9]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[10]  
Dorr LD, 1997, CLIN ORTHOP RELAT R, P157