Clinical application of BVS5000 left ventricular assist device in heart failure patients

被引:5
作者
Luo Xin-jin [1 ]
Hu Sheng-shou [1 ]
Sun Han-song [1 ]
Xu Jian-ping [1 ]
Liu Ping [1 ]
Zheng Zhe [1 ]
Ma Wei-guo [1 ]
Zhang Yan [1 ]
机构
[1] Peking Union Med Coll, Fu Wai Hosp, Dept Cardiovasc Surg, Beijing 100037, Peoples R China
关键词
heart failure; surgical treatment; left ventricular assist devices;
D O I
10.1097/00029330-200805020-00003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Mechanical ventricular assistance is an important therapeutic method for severe heart failure patients. A variety of ventricular assist devices have been designed for use. The purpose Of this report was to describe the experience of using Abiomed BVS5000 as a means of left ventricular support as a clinical treatment for heart failure patients. Methods From February 2004 to April 2006, 12 male patients were supported with Abiomed BVS5000 left ventricular assist device (LVAD) at Fu Wai Hospital. The average age was (55.2 +/- 9.6) years (range 39 to 68 years). The mean body surface area was (1.76 +/- 0.1) m(2) (range 1.6 to 1.9 m(2)). Devices were inserted for post-cardiotomy shock after coronary artery bypass graft in 11 patients (92%) and in 1 dilated cardiomyopathy patient for acute cardiogenic shock. Modified cannulation methods by inserting the arterial cannulae in femoral artery and inserting the venous cannula in left atrium through a segment of bovine jugular vein were used in 7 patients. In this way, the device could be taken off without re-sternotomy when support was finished. A comparison was made between the modified method and routine left atrium-to-ascending aorta cannulating method. Results The median duration of support was 5 (3-43) days, with support flow rate of 3.8-4.5 L/min. There were 9 (75%) patients weaned from support and 8 (67%) patients discharged from the hospital. Four (33%) patients were dead. The most common morbidity was adverse neurological events. There is no statistical difference between modified and routine method on average in BVS5000 support duration, in assisted flow rate, in mechanical ventilation duration, in the intensive care unit stay and thoracic drainage. Conclusions The Abiomed BVS5000 is valuable to support patients with acute cardiogenic shock for short-term use. By the modified cannulating method, the weaning procedure can be effectively simplified. Optimization of inserting indication remains challenging and attributes to a successful assist program.
引用
收藏
页码:877 / 880
页数:4
相关论文
共 20 条
  • [1] Altemose GT, 1997, J HEART LUNG TRANSPL, V16, P765
  • [2] LVAD-Induced reverse remodeling: Basic and clinical implications for myocardial recovery
    Burkhoff, D
    Klotz, S
    Mancini, DM
    [J]. JOURNAL OF CARDIAC FAILURE, 2006, 12 (03) : 227 - 239
  • [3] Five-year clinical experience with Abiomed BVS 5000 as a ventricular assist device for cardiac failure
    Dekkers, RJ
    FitzGerald, DJ
    Couper, GS
    [J]. PERFUSION-UK, 2001, 16 (01): : 13 - 18
  • [4] Selection and management of ventricular assist device patients: The Muenster experience
    Deng, MC
    Weyand, M
    Hammel, D
    Schmid, C
    Kerber, S
    Schmidt, C
    Breithardt, G
    Scheld, HH
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2000, 19 (08) : S77 - S82
  • [5] CLINICAL USE OF A CANNULA FOR LEFT HEART BYPASS WITHOUT THORACOTOMY - EXPERIMENTAL PROTECTION AGAINST FIBRILLATION BY LEFT HEART BYPASS
    DENNIS, C
    CARLENS, E
    HALL, DP
    SENNING, A
    MORENO, JR
    CAPPELLETTI, RR
    WESOLOWISKI, SA
    [J]. ANNALS OF SURGERY, 1962, 156 (04) : 623 - &
  • [6] Short- and long-term mechanical ventricular assistance towards myocardial recovery
    Entwistle, JWC
    [J]. SURGICAL CLINICS OF NORTH AMERICA, 2004, 84 (01) : 201 - +
  • [7] Improved left ventricular function after chronic left ventricular unloading
    Frazier, OH
    Benedict, CR
    Radovancevic, B
    Bick, RJ
    Capek, P
    Springer, WE
    Macris, MP
    Delgado, R
    Buja, LM
    [J]. ANNALS OF THORACIC SURGERY, 1996, 62 (03) : 675 - 681
  • [8] Neurological events during long-term mechanical circulatory support for heart failure - The Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience
    Lazar, RM
    Shapiro, PA
    Jaski, BE
    Parides, MK
    Bourge, RC
    Watson, JT
    Damme, L
    Dembitsky, W
    Hosenpud, JD
    Gupta, L
    Tierney, A
    Kraus, T
    Naka, Y
    [J]. CIRCULATION, 2004, 109 (20) : 2423 - 2427
  • [9] MECHANICAL VENTRICULAR SUPPORT USING PULSATILE ABIOMED BVS-5000 AND CENTRIFUGAL BIOMEDICUS-PUMP IN POSTCARDIOTOMY SHOCK
    MINAMI, K
    POSIVAL, H
    ELBYNAYOSY, A
    KORNER, MM
    SCHROFEL, H
    MURRAY, E
    KORFER, R
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (09) : 492 - 498
  • [10] Role of the abiomed BVS 5000 device for short-term support and bridge to transplantation
    Morgan, JA
    Stewart, AS
    Lee, BJ
    Oz, MC
    Naka, Y
    [J]. ASAIO JOURNAL, 2004, 50 (04) : 360 - 363