Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode

被引:122
|
作者
Liu, Ai-Lin [1 ,2 ]
Zhang, Shao-Bo [1 ]
Chen, Wei [1 ,2 ]
Lin, Xin-Hua [1 ]
Xia, Xing-Hua [2 ]
机构
[1] Fujian Med Univ, Fac Pharm, Dept Pharmaceut Anal, Fuzhou 350004, Peoples R China
[2] Nanjing Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2008年 / 23卷 / 10期
基金
中国国家自然科学基金;
关键词
poly-CCA modified GCE; electroanalysis; norepinephrine; ascorbic acid; uric acid; high selectivity;
D O I
10.1016/j.bios.2008.01.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel polycalconcarboxylic acid (CCA) modified glassy carbon electrode (GCE) was fabricated by electropolymerization and then successfully used to simultaneously determine ascorbic acid (AA), norepinephrine (NE) and uric acid (UA). The characterization of electrochemically synthesized Poly-CCA film was investigated by atomic force microscopy (AFM), electrochemical impedance spectroscopy (EIS) and voltammetric methods. It was found that the electrochemical behavior of the polymer-modified electrode depended on film thickness, i.e., the electropylmyerization time. Based on the electrochemical data, the charge transfer coefficient (a) and the surface coverage (F) were calculated. This poly-CCA modified GCE could reduce the overpotential of ascorbic acid (AA), norepinephrine (NE) and uric acid (UA) oxidation in phosphate buffer solution (pH 6.0), while it increases the peak current significantly. The current peak separations of AA/NE, NE/UA and AA/UA on this modified electrode are 91 mV, 256 mV and 390 mV in CV at 100 mV s(-1), respectively. Therefore, the voltammetric responses of these three compounds can be well resolved on the polymer-modified electrode, and simultaneously determination of these three compounds can be achieved. In addition, this modified electrode can be successfully applied to determine AA and NE in injection and UA in urine samples without interferences. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1488 / 1495
页数:8
相关论文
共 50 条
  • [1] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502
  • [2] Simultaneous Voltammetric Determination of Norepinephrine, Ascorbic Acid and Uric Acid by TTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, Bahaddurghatta E. Kumara
    Mahanthesha, Kurangalara R.
    Vishwanatha, Chandrashekar C.
    Kumar, Mohan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (05): : 555 - 573
  • [3] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Xinying Ma
    Mingyong Chao
    Meifeng Chen
    Russian Journal of Electrochemistry, 2014, 50 : 154 - 161
  • [4] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    Chen, Meifeng
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (02) : 154 - 161
  • [5] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 1086 - 1092
  • [6] Glassy Carbon Electrode Modified with Gold Nanoparticles and DNA for the Simultaneous Determination of Uric Acid and Norepinephrine under Coexistence of Ascorbic Acid
    Liping Lu
    Xiangqin Lin
    Analytical Sciences, 2004, 20 : 527 - 530
  • [7] Glassy carbon electrode modified with gold nanoparticles and DNA for the simultaneous determination of uric acid and norepinephrine under coexistence of ascorbic acid
    Lu, LP
    Lin, XQ
    ANALYTICAL SCIENCES, 2004, 20 (03) : 527 - 530
  • [8] Simultaneous cyclic voltammetric determination of norepinephrine, ascorbic acid and uric acid using TX-100 modified carbon paste electrode
    Chandrashekar, B. N.
    Swamy, B. E. Kumara
    ANALYTICAL METHODS, 2012, 4 (03) : 849 - 854
  • [9] Voltammetric studies of an oracet blue modified glassy carbon electrode and its application for the simultaneous determination of dopamine, ascorbic acid and uric acid
    Zare, HR
    Rajabzadeh, N
    Nasirizadeh, N
    Mazloum-Ardakani, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) : 60 - 69
  • [10] Simultaneous Voltammetric Determination of Ascorbic Acid, Dopamine and Uric Acid Using Polybromothymol Blue Film-Modified Glassy Carbon Electrode
    Xu, Xiongwei
    Lin, Qihuang
    Liu, Ailin
    Chen, Wei
    Weng, Xiuhua
    Wang, Changlian
    Lin, Xinhua
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (06) : 788 - 793