A self-normalized, full time-resolved scheme for fluorescence diffuse optical tomography

被引:2
作者
Gao, Feng [1 ]
Zhang, Limin [1 ]
He, Huiyuan [1 ]
Zhao, Huijuan [1 ]
Jiang, Jingying [1 ]
Tanikawa, Yukari [2 ]
Maijono, Andhi [3 ]
Yamada, Yukio [3 ]
机构
[1] Tianjin Univ, Coll Precis Instruments & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Natl Inst Adv Ind Sci & Technol, Inst Human Sci & BioMed Engn, Tsukuba 3058564, Japan
[3] Univ Electro Commun, Dept Mech Engn & Intelligent Syst, Tokyo 1828585, Japan
来源
MULTIMODAL BIOMEDICAL IMAGING III | 2008年 / 6850卷
关键词
fluorescence diffuse optical tomography; image reconstruction techniques; full time-resolved scheme; self-normalization; fluorescent yield and lifetime;
D O I
10.1117/12.756396
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A full time-resolved scheme that has been previously applied in diffuse optical tomography is extended to time-domain fluorescence diffuse optical tomography regime, based on a finite-element-finite-time-difference photon diffusion modeling and a Newton-Raphson inversion framework. The merits of using full time-resolved data are twofold: it helps evaluate the intrinsic performance of time-domain mode for improvement of image quality and set up a 'gold standard' for the development of computationally efficient featured-data-based algorithms, and provides a self-normalized implementation to preclude the necessary for the scaling-factor calibration and spectroscopic-feature assessments of the system as well as to overcome the adversity of system instability. We validate the proposed methodology using simulated data, and evaluate its performances in simultaneously recovering the fluorescent yield and lifetime as well as its superiority to the featured-data one in the fidelity of image reconstruction.
引用
收藏
页数:12
相关论文
共 42 条
  • [1] Novel receptor-targeted fluorescent contrast agents for in vivo tumor imaging
    Achilefu, S
    Dorshow, RB
    Bugaj, JE
    Rajagopalan, R
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (08) : 479 - 485
  • [2] Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study
    Alexandrakis, G
    Rannou, FR
    Chatziioannou, AF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) : 4225 - 4241
  • [3] Effect of optical property estimation accuracy on tomographic bioluminescence imaging: simulation of a combined optical-PET (OPET) system
    Alexandrakis, George
    Rannou, Fernando R.
    Chatziioannou, Arion F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (08) : 2045 - 2053
  • [4] A FINITE-ELEMENT APPROACH FOR MODELING PHOTON TRANSPORT IN TISSUE
    ARRIDGE, SR
    SCHWEIGER, M
    HIRAOKA, M
    DELPY, DT
    [J]. MEDICAL PHYSICS, 1993, 20 (02) : 299 - 309
  • [5] Optical tomography in medical imaging
    Arridge, SR
    [J]. INVERSE PROBLEMS, 1999, 15 (02) : R41 - R93
  • [6] Becker W., 2005, ADV TIME CORRELATED
  • [7] Simultaneous imaging and optode calibration with diffuse optical tomography
    Boas, DA
    Gaudette, T
    Arridge, SR
    [J]. OPTICS EXPRESS, 2001, 8 (05): : 263 - 270
  • [8] Cherry SR, 2004, PHYS MED BIOL, V49, pR13, DOI 10.1088/0031-9155/49/3/R01
  • [9] A finite-element-based reconstruction method for 3D fluorescence tomography
    Cong, AX
    Wang, G
    [J]. OPTICS EXPRESS, 2005, 13 (24) : 9847 - 9857
  • [10] Multichannel time-resolved optical tomographic imaging system
    Eda, H
    Oda, I
    Ito, Y
    Wada, Y
    Oikawa, Y
    Tsunazawa, Y
    Takada, M
    Tsuchiya, Y
    Yamashita, Y
    Oda, M
    Sassaroli, A
    Yamada, Y
    Tamura, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (09) : 3595 - 3602