Validating production of PET radionuclides in solid and liquid targets: Comparing Geant4 predictions with FLUKA and measurements

被引:7
作者
Amin, T. [1 ]
Infantino, A. [2 ]
Barlow, R. [1 ]
Hoehr, C. [3 ]
机构
[1] Univ Huddersfield, Huddersfield HD1 3DH, W Yorkshire, England
[2] European Org Nucl Res, CH-1211 Geneva 23, Switzerland
[3] TRIUMF, Vancouver, BC V6T 2A3, Canada
关键词
PET; Radionuclides; FLUKA; Geant4; PROTON-INDUCED REACTIONS; CROSS-SECTIONS; WATER TARGET; SIMULATION; ISOTOPES; TC-99M;
D O I
10.1016/j.apradiso.2017.12.009
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The Monte Carlo toolkit Geant4 is used to simulate the production of a number of positron emitting radio-nuclides: N-13, F-18, (44)sc, Mn-52, Co-55 Cu-61, Ga-68, Y-86, Zr-89 and Tc-94, which have been produced using a 13 MeV medical cyclotron. The results are compared to previous simulations with the Monte Carlo code FLUKA and experimental measurements. The comparison shows variable degrees of agreement for different isotopes. The mean absolute deviation of Monte Carlo results from experiments was 1.4 +/- 1.6 for FLUKA and 0.7 +/- 0.5 for Geant4 using TENDL cross sections with QGSP-BIC-A11HP physics. Both agree well within the large error, which is due to the uncertainties present in both experimentally determined and theoretical reaction cross sections. Overall, Geant4 has been confirmed as a tool to simulate radionuclide production at low proton energy.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 41 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]   Recent developments in GEANT4 [J].
Allison, J. ;
Amako, K. ;
Apostolakis, J. ;
Arce, P. ;
Asai, M. ;
Aso, T. ;
Bagli, E. ;
Bagulya, A. ;
Banerjee, S. ;
Barrand, G. ;
Beck, B. R. ;
Bogdanov, A. G. ;
Brandt, D. ;
Brown, J. M. C. ;
Burkhardt, H. ;
Canal, Ph. ;
Cano-Ott, D. ;
Chauvie, S. ;
Cho, K. ;
Cirrone, G. A. P. ;
Cooperman, G. ;
Cortes-Giraldo, M. A. ;
Cosmo, G. ;
Cuttone, G. ;
Depaola, G. ;
Desorgher, L. ;
Dong, X. ;
Dotti, A. ;
Elvira, V. D. ;
Folger, G. ;
Francis, Z. ;
Galoyan, A. ;
Garnier, L. ;
Gayer, M. ;
Genser, K. L. ;
Grichine, V. M. ;
Guatelli, S. ;
Gueye, P. ;
Gumplinger, P. ;
Howard, A. S. ;
Hrivnacova, I. ;
Hwang, S. ;
Incerti, S. ;
Ivanchenko, A. ;
Ivanchenko, V. N. ;
Jones, F. W. ;
Jun, S. Y. ;
Kaitaniemi, P. ;
Karakatsanis, N. ;
Karamitrosi, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 835 :186-225
[4]   Modelling PET radionuclide production in tissue and external targets using Geant4 [J].
Amin, T. ;
Infantino, A. ;
Lindsay, C. ;
Barlow, R. ;
Hoehr, C. .
8TH INTERNATIONAL PARTICLE ACCELERATOR CONFERENCE (IPAC 2017), 2017, 874
[5]  
[Anonymous], 2017, HAMILTON PRECISION M
[6]  
[Anonymous], 2005, CERN YELLOW REPORTS
[7]   Implementation of Multi-Curie Production of 99mTc by Conventional Medical Cyclotrons [J].
Benard, Francois ;
Buckley, Kenneth R. ;
Ruth, Thomas J. ;
Zeisler, Stefan K. ;
Klug, Julius ;
Hanemaayer, Victoire ;
Vuckovic, Milan ;
Hou, Xinchi ;
Celler, Anna ;
Appiah, Jean-Pierre ;
Valliant, John ;
Kovacs, Michael S. ;
Schaffer, Paul .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (06) :1017-1022
[8]   The FLUKA Code: Developments and Challenges for High Energy and Medical Applications [J].
Boehlen, T. T. ;
Cerutti, F. ;
Chin, M. P. W. ;
Fosso, A. ;
Ferrari, A. ;
Ortega, P. G. ;
Mairani, A. ;
Sala, P. R. ;
Smirnov, G. ;
Vlachoudisl, V. .
NUCLEAR DATA SHEETS, 2014, 120 :211-214
[9]   11C-methane production in small volume, high pressure gas targets [J].
Buckley, KR ;
Huser, J ;
Jivan, S ;
Chun, KS ;
Ruth, TJ .
RADIOCHIMICA ACTA, 2000, 88 (3-4) :201-205
[10]   Induced activation in accelerator components [J].
Bungau, Cristian ;
Bungau, Adriana ;
Cywinski, Robert ;
Barlow, Roger ;
Edgecock, Thomas Robert ;
Carlsson, Patrick ;
Danared, Hakan ;
Mezei, Ferenc ;
Holm, Anne Ivalu Sander ;
Moller, Soren Pape ;
Thomsen, Heine Dolrath .
PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2014, 17 (08)