共 38 条
A new ready-to-use gel-based electrolyte for paraquat sensor
被引:25
作者:
Charoenkitamorn, Kanokwan
[1
]
Chotsuwan, Chuleekorn
[2
,3
]
Chaiyo, Sudkate
[1
,4
]
Siangproh, Weena
[5
]
Chailapakul, Orawon
[1
,3
]
机构:
[1] Chulalongkorn Univ, Fac Sci, Electrochem & Opt Spect Ctr Excellence EOSCE, Dept Chem, 254 Phayathai Rd, Bangkok 10330, Thailand
[2] Natl Sci & Technol Dev Agcy NSTDA, Natl Nanotechnol Ctr NANOTEC, Pathum Thani 12120, Thailand
[3] Chulalongkorn Univ, Fac Sci, Nanotec CU Ctr Excellence Food & Agr, Dept Chem, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Inst Biotechnol & Genet Engn, Bangkok 10330, Thailand
[5] Srinakharinwirot Univ, Fac Sci, Dept Chem, Sukhumvit 23, Bangkok 10110, Thailand
关键词:
Ready-to-use sensor;
Gel-based electrolyte;
Paraquat;
Polyvinyl alcohol;
Nafion;
Screen-printed graphene electrode;
GOLD NANOPARTICLE COMPOSITE;
GLASSY-CARBON ELECTRODE;
SQUARE-WAVE VOLTAMMETRY;
SENSITIVE DETERMINATION;
ELECTROCHEMICAL SENSOR;
POLYMER;
BIOSENSOR;
GRAPHENE;
SAMPLES;
IMMUNOSENSOR;
D O I:
10.1016/j.snb.2020.128089
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
A ready-to-use electrochemical sensor offering the simplicity and portability for on-site analysis is currently in demand. Herein, we first demonstrated a new ready-to-use electrochemical sensor for on-site analysis of paraquat (PQ) using polyvinyl alcohol (PVA) gel-electrolyte. For the preparation of gel-electrolyte, hydrolyzed PVA was dissolved in DMSO: water media, allowed to cool down to room temperature before adding LiClO4, and casted onto an electrode surface. To perform the experiment, nafion-modified screen-printed graphene electrode (Nf/SPGE) was used to enhance the electrochemical signal of PQ detection using differential pulse voltammetry (DPV). Under the optimal conditions, the detection limit of 0.31 mu mol L-1 was obtained. Moreover, this article reported on the comparison of PQ detection obtained from ready-to-use gel-electrolyte and liquid-electrolyte. Finally, the proposed sensor was applied for the quantitative analysis of PQ in real samples. The operation can be easily performed by directly introducing sample solution onto the sensor without any additional sample preparation. This makes a device easy to carry out for field analysis. Additionally, this newly ready-to-use electrochemical platform displays good reproducibility, high stability, simple preparation, low-cost, disposability, and portability, which makes it suitable for various applications.
引用
收藏
页数:10
相关论文