New design total knee arthroplasty shows medial pivoting movement under weight-bearing conditions

被引:18
作者
Bragonzoni, Laura [2 ]
Muccioli, Giulio Maria Marcheggiani [1 ,2 ]
Bontempi, Marco [2 ]
di Sarsina, Tommaso Roberti [1 ]
Cardinale, Umberto [2 ]
Alesi, Domenico [1 ]
Iacono, Francesco [3 ]
Neri, Maria Pia [1 ]
Zaffagnini, Stefano [1 ]
机构
[1] Ist Ortoped Rizzoli, IRCCS, Orthopaed & Traumatol Clin 2, Lab Biomeccan, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Univ Bologna, Bologna, Italy
[3] Humanitas Clin Inst, Prosthet Surg & Articular Biol Reconstruct, Milan, Italy
关键词
Dynamic radiostereometric analysis; Total knee arthroplasty; In vivo knee kinematics; IN-VIVO KINEMATICS; MOBILE-BEARING; LIVING KNEE; FLEXION; TKA; REPLACEMENT; STABILITY; GEOMETRY;
D O I
10.1007/s00167-018-5243-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo assess, using model-based dynamic radiostereometric analysis (RSA), the biomechanical behaviour of a new design posterior-stabilized (PS) fixed-bearing (FB) total knee arthroplasty (TKA) in vivo while patients performing two common motor tasks. The hypothesis was that model-based dynamic RSA is able to detect different behaviour of the implant under weight-bearing and non-weight-bearing conditions.MethodsA cohort of 15 non-consecutive patients was evaluated by dynamic RSA 9months after TKA implantation. The mean age of patients was 73.4 (65-72) years. The kinematic evaluations were performed using an RSA device (BI-STAND DRX 2) developed in our Institute. The patients were asked to perform two active motor tasks: sit-to-stand in weight-bearing condition; range of motion (ROM) while sitting on the chair. The motion parameters were evaluated using the Grood and Suntay decomposition and the low-point kinematics methods.ResultsThe dynamic RSA evaluation showed a significant difference (p<0.05) between the biomechanical behaviour of the prosthesis during the two motor tasks. When subjected to the patient weight (in the sit-to-stand) the low point of the medial compartment had a shorter motion (5.70.2mm) than the lateral (11.00.2mm). This realizes a medial pivot motion as in the normal knee. In the ROM task, where the patient had no weight on the prosthesis, this difference was not present: the medial compartment had a displacement of 12.7 +/- 0.2mm, while the lateral had 17.3 +/- 0.2mm.Conclusions Model-based RSA proved to be an effective tool for the evaluation of TKA biomechanics. In particular, it was able to determine that the fixed-bearing posterior-stabilized TKA design evaluated in this study showed a medial pivoting movement under weight-bearing conditions that was not present when load was not applied. Under loading conditions what drives the pattern of movement is the prosthetic design itself. By the systematic use of this study protocol future comparisons among different implants could be performed, thus contributing significantly to the improvement of TKA design.Level of evidence IV.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 30 条
[11]   The movement of the knee studied by magnetic resonance imaging [J].
Freeman, MAR ;
Pinskerova, V .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :35-43
[12]  
Ginsel BL, 2009, ACTA ORTHOP BELG, V75, P801
[13]   A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[14]  
Hsu Robert Wen-Wei, 2006, Chang Gung Med J, V29, P448
[15]   Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee [J].
Iwaki, H ;
Pinskerova, V ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1189-1195
[16]  
JCGM, 2008, JCGM100 GUID EXPR UN
[17]   Gait analysis comparison of cruciate retaining and substituting TKA following PCL sacrifice [J].
Joglekar, Siddharth ;
Gioe, Terence J. ;
Yoon, Patrick ;
Schwartz, Michael H. .
KNEE, 2012, 19 (04) :279-285
[18]   Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using 'interventional' MRI [J].
Johal, P ;
Williams, A ;
Wragg, P ;
Hunt, D ;
Gedroyc, W .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :269-276
[19]   In vivo fluoroscopic analysis of the normal human knee [J].
Komistek, RD ;
Dennis, DA ;
Mahfouz, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :69-81
[20]   Cruciate-retaining and cruciate-substituting total knee arthroplasty -: An in vitro comparison of the kinematics under muscle loads [J].
Li, G ;
Zayontz, S ;
Most, E ;
Otterberg, E ;
Sabbag, K ;
Rubash, HE .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :150-156