Diagnostic Value of Contrast-Enhanced Ultrasound Image Features under Deep Learning in Benign and Malignant Thyroid Lesions

被引:4
|
作者
Xu, Ping [1 ]
Du, Zusheng [1 ]
Sun, Long [1 ]
Zhang, Yan [1 ]
Zhang, Jingjing [1 ]
Qiu, Qin [1 ]
机构
[1] Ningbo Yinzhou 2 Hosp, Dept Ultrasound, Ningbo 315192, Zhejiang, Peoples R China
关键词
NODULES;
D O I
10.1155/2022/6786966
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
This study aimed to analyze the application of the diagnostic model based on deep learning technology in the evaluation of thyroid contrast-enhanced ultrasound images and to provide a reference for the evaluation of benign and malignant thyroid. A diagnosis model of ultrasound images based on long- and short-term memory neural network (LSTM), C-LSTM, was proposed. The diagnostic method was compared with that based on support vector machine (SVM) and manual feature (MF), and it was applied to the diagnosis of thyroid contrast-enhanced ultrasound images. The results showed that the sensitivity, specificity, and accuracy of the C-LSTM model were greatly higher than those of SVM and MF, and the differences were considerable (P < 0.05). The number of parameters and the calculation amount of the C-LSTM model were greatly lower than those of SVM- and MF-based diagnosis methods (P < 0.05). The sensitivity, specificity, and accuracy of the C-LSTM model were greatly greater than those of the C-LSTM-0 model, while the amounts of parameters and calculations were greatly lesser than those of the C-LSTM-0 model (P < 0.05). The numbers of benign tumors with contrast-enhanced ultrasound modes of no enhancement, no enhancement at early stage, and low enhancement were more than those of malignant tumors, while the numbers of high-enhancement tumors were greatly less than those of malignant tumors (P < 0.05). The diagnostic area under the curve (AUC) of rise time (RT) ratio, time to peak (TTP) ratio, and mean transit time (mTT) ratio for malignant masses were large, which were 0.856, 0.794, and 0.761, respectively. RT ratio, TTP ratio, and mTT ratio were of high diagnostic sensitivity and specificity for malignant masses, while RT, TTP, and mTT were of low diagnostic sensitivity and specificity. In summary, the contrast-enhanced ultrasound images based on the deep learning C-LSTM model can effectively improve the diagnostic effect of benign and malignant thyroid masses. The image feature parameters RT ratio, TTP ratio, and mTT ratio were of good efficiency in diagnosing benign and malignant thyroid masses.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Contrast-enhanced ultrasound is helpful for differentiating benign from malignant parietal pleural lesions
    Findeisen, Hajo
    Goerg, Christian
    Hartbrich, Ruby
    Dietrich, Christoph Frank
    Goerg, Konrad
    Trenker, Corinna
    Zadeh, Ehsan Safai
    JOURNAL OF CLINICAL ULTRASOUND, 2022, 50 (01) : 90 - 98
  • [32] Application of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Benign and Malignant Subpleural Pulmonary Lesions
    Shen, MengJun
    Bi, Ke
    Cong, Yang
    Chen, HongWei
    Zhang, Yi
    Zhu, HuiMing
    Wang, Yin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1147 - 1157
  • [33] Clinical diagnostic value of contrast-enhanced ultrasound and TI-RADS classification for benign and malignant thyroid tumors One comparative cohort study
    Xu, Yan
    Qi, Xiaojie
    Zhao, Xia
    Ren, Wenfeng
    Ding, Wei
    MEDICINE, 2019, 98 (04)
  • [34] Ultrasomics differentiation of malignant and benign focal liver lesions based on contrast-enhanced ultrasound
    Hu, Hang-Tong
    Li, Ming-De
    Zhang, Jian-Chao
    Ruan, Si-Min
    Wu, Shan-Shan
    Lin, Xin-Xin
    Kang, Hai-Yu
    Xie, Xiao-Yan
    Lu, Ming-De
    Kuang, Ming
    Xu, Er-Jiao
    Wang, Wei
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [35] Meta-analysis of contrast-enhanced ultrasound for the differentiation of benign and malignant breast lesions
    Hu, Qiao
    Wang, Xiao Yan
    Zhu, Shang Yong
    Kang, Li Ke
    Xiao, Yan Ju
    Zheng, Hong Yu
    ACTA RADIOLOGICA, 2015, 56 (01) : 25 - 33
  • [36] Diagnostic value of contrast-enhanced ultrasound in solid thyroid nodules with and without enhancement
    Qiong Wu
    Yan Wang
    Yi Li
    Bing Hu
    Zhi-Yan He
    Endocrine, 2016, 53 : 480 - 488
  • [37] Diagnostic value of contrast-enhanced ultrasound in solid thyroid nodules with and without enhancement
    Wu, Qiong
    Wang, Yan
    Li, Yi
    Hu, Bing
    He, Zhi-Yan
    ENDOCRINE, 2016, 53 (02) : 480 - 488
  • [38] Diagnostic value of "absent" pattern in contrast-enhanced ultrasound for the differentiation of thyroid nodules
    Wu, Qiong
    Li, Yi
    Wang, Yan
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 63 (04) : 325 - 334
  • [39] Application of ultrasonic shear wave elastography and contrast-enhanced ultrasound in the differential diagnosis of patients with benign and malignant thyroid lesions
    Xu, Jing
    Wang, Ping
    Yue, Wensheng
    Luo, Yuqun
    Li, Zukun
    GLAND SURGERY, 2020, 9 (06) : 2136 - 2143
  • [40] Value contrast-enhanced ultrasound in the diagnostic evaluation of complex cystic renal lesions
    Pallwein, Leo
    Mitterberger, Michael
    Gradl, Johannes
    Aigner, Friedrich
    Strasser, Hannes
    Peschel, Reinhard
    Bartsch, Georg
    Pinggera, Germar M.
    Frauscher, Ferdinand
    JOURNAL OF UROLOGY, 2008, 179 (04): : 415 - 415