Effects of tracheal orientation on development of ventilator-associated pneumonia: an experimental study

被引:30
作者
Zanella, Alberto [2 ,3 ]
Cressoni, Massimo [1 ,2 ,6 ]
Epp, Myra [2 ]
Hoffmann, Viktoria [4 ]
Stylianou, Mario [5 ]
Kolobow, Theodor [2 ]
机构
[1] Univ Milan, Osped Maggiore Policlin, Fdn IRCCS Ca Granda, Dipartimento Anestesiol Terapia Intens & Sci Derm, Milan, Italy
[2] NHLBI, NIH, Sect Pulm & Cardiac Assist Devices, Pulm & Crit Care Med Branch, Bethesda, MD 20892 USA
[3] Milano Bicocca Univ, San Gerardo Hosp, Dept Expt Med, Monza, Italy
[4] NIH, Div Vet Res, Bethesda, MD 20892 USA
[5] NHLBI, NIH, Off Biostat Res, Bethesda, MD 20892 USA
[6] Osped Maggiore Policlin, Fdn IRCCS Ca Granda, Dipartimento Anestesia Rianimaz Intens & Subinten, Milan, Italy
关键词
Mechanical ventilation; Pneumonia; Ventilator-associated pneumonia; Semirecumbent position; Intubation; Postural drainage; Pulmonary; Pigs; Nosocomial infections; Respiration; Artificial/adverse effects; Intratracheal/adverse effects; Respiratory tract infections/prevention and control; Aspiration/prevention and control; CARE-UNIT PATIENTS; NOSOCOMIAL PNEUMONIA; RESPIRATORY-TRACT; MECHANICAL VENTILATION; SEMIRECUMBENT POSITION; BACTERIAL-COLONIZATION; PULMONARY ASPIRATION; ENDOTRACHEAL-TUBE; BODY POSITION; PATHOGENESIS;
D O I
10.1007/s00134-012-2495-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Orientation of the trachea and tracheal tube below horizontal may prevent aspiration of oropharyngeal secretions into the lungs, which is a pivotal pathway in the pathogenesis of ventilator-associated pneumonia (VAP). The incidence of VAP was evaluated in swine with orientation of trachea and tracheal tube above horizontal (model of semirecumbent position, currently recommended in patients) and below horizontal. Twenty-six mini-pigs were randomized into four groups: (A) eight mechanically ventilated with orientation of trachea 45A degrees above horizontal for 72 h. In the remaining groups (B, C, D) the trachea was oriented 10A degrees below horizontal, with (B) six mechanically ventilated for 72 h, (C) six mechanically ventilated for 72 h with enteral feeding, and (D) six mechanically ventilated for 168 h with enteral feeding. At the end of the study period, all pigs were sacrificed and the clinical diagnosis of VAP was microbiologically evaluated. No antibiotics were administered. All eight pigs kept orientated with the trachea 45A degrees above horizontal developed VAP and respiratory failure (PaO2/FiO2 = 132 +/- A 139 mmHg) with a median of 5.5 pulmonary lobes out of 6 colonized with average colonization of 9.3 x 10(7) CFU/g. None of the 18 pigs kept oriented with the trachea below horizontal developed VAP; 16 had sterile lungs, while 2, ventilated for 7 days, developed a low level of colonization. Orientation of the trachea above horizontal was uniformly associated with VAP and respiratory failure; positioning the trachea below horizontal consistently prevented development of VAP.
引用
收藏
页码:677 / 685
页数:9
相关论文
共 25 条
[21]   GASTRIC AND PHARYNGEAL FLORA IN NOSOCOMIAL PNEUMONIA ACQUIRED DURING MECHANICAL VENTILATION [J].
TORRES, A ;
ELEBIARY, M ;
GONZALEZ, J ;
FERRER, M ;
DELABELLACASA, JP ;
GENE, A ;
MARTOS, A ;
RODRIGUEZROISIN, R .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (02) :352-357
[22]   PULMONARY ASPIRATION OF GASTRIC CONTENTS IN PATIENTS RECEIVING MECHANICAL VENTILATION - THE EFFECT OF BODY POSITION [J].
TORRES, A ;
SERRABATLLES, J ;
ROS, E ;
PIERA, C ;
DELABELLACASA, JP ;
COBOS, A ;
LOMENA, F ;
RODRIGUEZROISIN, R .
ANNALS OF INTERNAL MEDICINE, 1992, 116 (07) :540-543
[23]   Feasibility and effects of the semirecumbent position to prevent ventilator-associated pneumonia: A randomized study [J].
van Nieuwenhoven, CA ;
Vandenbroucke-Grauls, C ;
van Tiel, FH ;
Joore, HCA ;
van Schijndel, RJMS ;
van der Tweel, I ;
Ramsay, G ;
Bonten, MJM .
CRITICAL CARE MEDICINE, 2006, 34 (02) :396-402
[24]   THE PREVALENCE OF NOSOCOMIAL INFECTION IN INTENSIVE-CARE UNITS IN EUROPE - RESULTS OF THE EUROPEAN PREVALENCE OF INFECTION IN INTENSIVE-CARE (EPIC) STUDY [J].
VINCENT, JL ;
BIHARI, DJ ;
SUTER, PM ;
BRUINING, HA ;
WHITE, J ;
NICOLASCHANOIN, MH ;
WOLFF, M ;
SPENCER, RC ;
HEMMER, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (08) :639-644
[25]   A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study [J].
Zanella, Alberto ;
Cressoni, Massimo ;
Epp, Myra ;
Stylianou, Mario ;
Kolobow, Theodor .
INTENSIVE CARE MEDICINE, 2008, 34 (06) :1145-1149