Diagnosis Technique for Stator Winding Inter-Turn Fault in BLDC Motor using Detection Coil

被引:0
作者
Lee, Seung-Tae [1 ]
Kim, Kyung-Tae [1 ]
Hur, Jin [1 ]
机构
[1] Univ Ulsan, Sch Elect Engn, 102 St Dae Hak, Ulsan 680749, South Korea
来源
2015 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE-ECCE ASIA) | 2015年
关键词
Brushless DC motor; fault detection; fault diagnosis; inter-turn fault; SHORT-CIRCUIT FAULT; INDUCTION-MOTORS; TORQUE RIPPLE; MACHINES; IDENTIFICATION; SYSTEMS; POWER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Brushless direct-current (BLDC) motors are widely used in industrial applications. These motors should be considered for high stability and reliability under faults which can seriously threaten safe operation. Among these fault types, a stator winding inter-turn fault (ITF) is one of the most common faults that occur in BLDC motors. Moreover, the propagation of the fault could quickly lead to shutdown of the motor within a few seconds. In order to prevent the problem, we proposed a diagnosis technique of ITF using variations of back electromotive force generated in detection coils in BLDC motors. The technique can relatively achieve more rapid response and lower cost than previous detection techniques, because the proposed technique does not require spectral analysis and complicated computation. The detection technique is verified by simulation and experiment under dynamic fault.
引用
收藏
页码:2925 / 2931
页数:7
相关论文
共 14 条
[1]   Online stator fault diagnosis in induction motors [J].
Arkan, M ;
Perovic, DK ;
Unsworth, P .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2001, 148 (06) :537-547
[2]   CAUSE AND ANALYSIS OF STATOR AND ROTOR FAILURES IN 3-PHASE SQUIRREL-CAGE INDUCTION-MOTORS [J].
BONNETT, AH ;
SOUKUP, GC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (04) :921-937
[3]  
Bonnett AH, 2008, IEEE IND APPL MAG, V14, P29, DOI 10.1109/MIA.2007.909802
[4]   ANALYSIS OF TORQUE RIPPLE DUE TO PHASE COMMUTATION IN BRUSHLESS DC MACHINES [J].
CARLSON, R ;
LAJOIEMAZENC, M ;
FAGUNDES, JCD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (03) :632-638
[5]   An Impedance Identification Approach to Sensitive Detection and Location of Stator Turn-to-Turn Faults in a Closed-Loop Multiple-Motor Drive [J].
Cheng, Siwei ;
Zhang, Pinjia ;
Habetler, Thomas G. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1545-1554
[6]   Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors [J].
Gandhi, Arun ;
Corrigan, Timothy ;
Parsa, Leila .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1564-1575
[7]   Characteristic analysis of interior permanent-magnet synchronous motor in electrohydraulic power steering systems [J].
Hur, Jin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (06) :2316-2323
[8]  
Kim K. H., 2009, J KOREAN I ILLUM ELE, V23, P18
[10]   Internal short circuit fault diagnosis for PM machines using FE-based phase variable model and wavelets analysis [J].
Mohammed, O. A. ;
Liu, Z. ;
Liu, S. ;
Abed, N. Y. .
IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (04) :1729-1732