Cascaded optical link on a telecommunication fiber network for ultra-stable frequency dissemination

被引:1
作者
Lopez, Olivier [1 ]
Chiodo, Nicola [1 ]
Stefani, Fabio [1 ,2 ]
Wiotte, Fabrice [1 ]
Quintin, Nicolas [1 ]
Bercy, Anthony [1 ,2 ]
Chardonnet, Christian [1 ]
Santarelli, Giorgio [3 ,4 ]
Pottie, Paul-Eric [2 ]
Amy-Klein, Anne [1 ]
机构
[1] Univ Paris 13, Sorbonne Paris Cite, Lab Phys Lasers, Villetaneuse, France
[2] UPMC, CNRS, Observ Paris, LNE SYRTE, Paris, France
[3] Univ Bordeaux 1, Lab Photon Numer & Nanosci, Inst Opt, F-33405 Talence, France
[4] CNRS, Talence, France
来源
SLOW LIGHT, FAST LIGHT, AND OPTO-ATOMIC PRECISION METROLOGY VIII | 2015年 / 9378卷
关键词
optical link; time-frequency metrology; phase stabilization; optical clocks; TIME-VARYING PATH; LATTICE CLOCK; STABILITY; CANCELLATION; ACCURACY; COUNTERS; LEVEL;
D O I
10.1117/12.2083830
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The transfer of ultra-stable frequencies between distant laboratories is required by many applications in time and frequency metrology, fundamental physics, particle accelerators and astrophysics. Optical fiber links have been intensively studied for a decade and brought the potential to transfer frequency with a very high accuracy and stability thanks to an active compensation of the propagation noise. We are currently developing an optical metrological network using the fibers of the French National Research and Education Network. Using the so-called dark-channel approach, the ultrastable signal is copropagating with data traffic using wavelength division multiplexing. Due to significant reflections and losses along the fibers, which cannot be compensated with amplifiers, we have developed some repeater stations for the metrological signal. These remotely-operated stations amplify the ultrastable signal and compensate the propagation noise. The link is thus composed of a few cascaded spans. It gives the possibility to increase the noise correction bandwidth, which is proportional to the inverse of the fiber length for each span. These stations are a key element for the deployment of a reliable and large scale metrological network. We report here on the implementation of a two-spans cascaded link of 740 km reaching a relative stability of a few 10-20 after 103 s averaging time. Extension to longer links and alternative transfer methods will be discussed.
引用
收藏
页数:6
相关论文
共 33 条
[1]  
[Anonymous], ARXIV14054071
[2]   Comparison between frequency standards in Europe and the USA at the 10-15 uncertainty level [J].
Bauch, A ;
Achkar, J ;
Bize, S ;
Calonico, D ;
Dach, R ;
Hlavac, R ;
Lorini, L ;
Parker, T ;
Petit, G ;
Piester, D ;
Szymaniec, K ;
Uhrich, P .
METROLOGIA, 2006, 43 (01) :109-120
[3]   Two-way optical frequency comparisons at 5 x 10-21 relative stability over 100-km telecommunication network fibers [J].
Bercy, Anthony ;
Stefani, Fabio ;
Lopez, Olivier ;
Chardonnet, Christian ;
Pottie, Paul-Eric ;
Amy-Klein, Anne .
PHYSICAL REVIEW A, 2014, 90 (06)
[4]   In-line extraction of an ultrastable frequency signal over an optical fiber link [J].
Bercy, Anthony ;
Guellati-Khelifa, Saida ;
Stefani, Fabio ;
Santarelli, Giorgio ;
Chardonnet, Christian ;
Pottie, Paul-Eric ;
Lopez, Olivier ;
Amy-Klein, Anne .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2014, 31 (04) :678-685
[5]   An optical lattice clock with accuracy and stability at the 10-18 level [J].
Bloom, B. J. ;
Nicholson, T. L. ;
Williams, J. R. ;
Campbell, S. L. ;
Bishof, M. ;
Zhang, X. ;
Zhang, W. ;
Bromley, S. L. ;
Ye, J. .
NATURE, 2014, 506 (7486) :71-+
[6]   High-accuracy coherent optical frequency transfer over a doubled 642-km fiber link [J].
Calonico, D. ;
Bertacco, E. K. ;
Calosso, C. E. ;
Clivati, C. ;
Costanzo, G. A. ;
Frittelli, M. ;
Godone, A. ;
Mura, A. ;
Poli, N. ;
Sutyrin, D. V. ;
Tino, G. M. ;
Zucco, M. E. ;
Levi, F. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 117 (03) :979-986
[7]   Frequency transfer via a two-way optical phase comparison on a multiplexed fiber network [J].
Calosso, C. E. ;
Bertacco, E. ;
Calonico, D. ;
Clivati, C. ;
Costanzo, G. A. ;
Frittelli, M. ;
Levi, F. ;
Mura, A. ;
Godone, A. .
OPTICS LETTERS, 2014, 39 (05) :1177-1180
[8]   Mid-infrared laser phase-locking to a remote near-infrared frequency reference for high-precision molecular spectroscopy [J].
Chanteau, B. ;
Lopez, O. ;
Zhang, W. ;
Nicolodi, D. ;
Argence, B. ;
Auguste, F. ;
Abgrall, M. ;
Chardonnet, C. ;
Santarelli, G. ;
Darquie, B. ;
Le Coq, Y. ;
Amy-Klein, A. .
NEW JOURNAL OF PHYSICS, 2013, 15
[9]   Optical Clocks and Relativity [J].
Chou, C. W. ;
Hume, D. B. ;
Rosenband, T. ;
Wineland, D. J. .
SCIENCE, 2010, 329 (5999) :1630-1633
[10]   Considerations on the measurement of the stability of oscillators with frequency counters [J].
Dawkins, Samuel T. ;
McFerran, John J. ;
Luiten, Andre N. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (05) :918-925