Numerical and Experimental Investigations of Composite Solar Walls Integrating Sensible or Latent Heat Thermal Storage

被引:3
作者
Leang, Enghok [1 ]
Tittelein, Pierre [1 ]
Zalewski, Laurent [1 ]
Lassue, Stephane [1 ]
机构
[1] Univ Artois, LGCgE, ULR 4515, F-62400 Bethune, France
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 05期
关键词
composite Trombe wall; phase change material; micro-encapsulated PCM; PHASE-CHANGE MATERIALS; PV-TROMBE WALL; ENERGY STORAGE; BUILDING APPLICATIONS; NATURAL-CONVECTION; CEMENT MORTAR; PERFORMANCE; SYSTEM; BEHAVIOR; PCM;
D O I
10.3390/app10051854
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This article studies a composite solar wall with latent storage (TES) designed to heat rooms inside buildings during the cold season. No numerical model of the composite solar wall is currently available in the Dymola/Modelica software library. The first objective of this work is to develop one such model. The article describes the elementary components, along with the equations that allow modeling the heat transfers and storage phenomena governing both the thermal behavior and performance of the solar wall. This model was built by assembling various existing basic elements from the software's "Building" library (e.g., models of heat transfer by convection, radiation and conduction) and then creating new elements, such as the storage element incorporating the phase change material (PCM). To validate this solar wall model, numerical results are compared to experimental data stemming from a small-scale composite solar wall manufactured in our laboratory, and the experimental set-up could be tested under real weather conditions. After verifying the level of confidence in the model, the energy performance of two solar walls, one with a conventional storage wall (sensible heat storage) the other containing a PCM (the same as in the experiment), are compared. The result indicates that the solar wall incorporating a PCM does not in this case release any more energy in the room to be heated.
引用
收藏
页数:26
相关论文
共 69 条
[41]   DESIGN AND OPERATION OF A LOW-ENERGY CONSUMPTION PASSIVE SOLAR AGRICULTURAL GREENHOUSE [J].
SANTAMOURIS, M ;
ARGIRIOU, A ;
VALLINDRAS, M .
SOLAR ENERGY, 1994, 52 (05) :371-378
[42]   Review on thermal energy storage with phase change materials and applications [J].
Sharma, Atul ;
Tyagi, V. V. ;
Chen, C. R. ;
Buddhi, D. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (02) :318-345
[43]   Numerical study on thermal behavior of classical or composite Trombe solar walls [J].
Shen, Jibao ;
Lassue, Stephane ;
Zalewski, Laurent ;
Huang, Dezhong .
ENERGY AND BUILDINGS, 2007, 39 (08) :962-974
[44]   THEORETICAL AND EXPERIMENTAL INVESTIGATIONS OF HEAT-TRANSFER IN A TROMBE WALL [J].
SMOLEC, W ;
THOMAS, A .
ENERGY CONVERSION AND MANAGEMENT, 1993, 34 (05) :385-400
[45]   EFFECT OF FINITE WIDTH ON HEAT-TRANSFER AND FLUID-FLOW ABOUT AN INCLINED RECTANGULAR PLATE [J].
SPARROW, EM ;
RAMSEY, JW ;
MASS, EA .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1979, 101 (02) :199-204
[46]   The behaviour of solar walls in residential buildings with different insulation levels: An experimental and numerical study [J].
Stazi, Francesca ;
Mastrucci, Alessio ;
di Perna, Costanzo .
ENERGY AND BUILDINGS, 2012, 47 :217-229
[47]   Solar heat storage wall for building ventilation [J].
Stritih, U ;
Novak, P .
RENEWABLE ENERGY, 1996, 8 (1-4) :268-271
[48]   Performance of PV-Trombe wall in winter correlated with south facade design [J].
Sun, Wei ;
Ji, Jie ;
Luo, Chenglong ;
He, Wei .
APPLIED ENERGY, 2011, 88 (01) :224-231
[49]  
Swet C.J., 1980, Proc. Annu. Meet. - Am. Sect. Int. Sol. Energy Soc, V5, P282
[50]   Periodic modeling of semi-transparent photovoltaic thermal-trombe wall (SPVT-TW) [J].
Taffesse, Firehun ;
Verma, Ashu ;
Singh, Sugandha ;
Tiwari, G. N. .
SOLAR ENERGY, 2016, 135 :265-273