Preconcentration and determination of four antibiotics in biological samples using nanofluid-assisted magnetic dispersive micro-solid-phase extraction coupled with high-performance liquid chromatography

被引:10
|
作者
Saghafi, Ava [1 ]
Sanavi Khoshnood, Razieh [1 ]
Sanavi Khoshnoud, Davoud [2 ]
Eshaghi, Zarrin [3 ]
机构
[1] Islamic Azad Univ, Mashhad Branch, Dept Chem, Mashhad, Razavi Khorasan, Iran
[2] Semnan Univ, Fac Phys, POB 35195-363, Semnan, Iran
[3] Payam Noor Univ, Dept Chem, Tehran, Iran
关键词
Magnetic dispersive micro-solid-phase extraction; Nanofluids; Antibiotics; High-performance liquid chromatography; Biological sample; Water samples; REAL WATER; MICROEXTRACTION METHOD; RESISTANCE; CHALLENGES; SORBENTS; URINE; GREEN; SOIL;
D O I
10.1007/s11696-021-01903-5
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A sensitive and straightforward magnetic dispersive micro-solid-phase extraction as a sample preparation procedure coupled with high-performance liquid chromatography was developed to preconcentrate and clean up four antibiotics, including azithromycin (AZI), doxycycline (DOX), amoxicillin (AMO), and tetracycline (TC), from biological samples. For this purpose, several nanofluids with a magnetic colloidal gel structure were prepared based on the dispersion of three synthetic nanoparticles in dimethylformamide in the presence of an ionic liquid individually. The nanofluid preparation leads to a reduction in the extraction and desorption time and sorbent consumption through an increase in the sorbent surface area. Usage of the nanofluid can also increase the sorbent dispersion efficiency without using a dispersion agent. The ability of the magnetic colloidal gels to simultaneously extract the antibiotics was compared together. An experimental design including screening and optimization steps was utilized to optimize effective factors in the micro-extraction method. Under the optimum condition, the proposed method has linearity in the concentration ranges of 0.01-12.0, 0.01-12.0, 0.01-15.0, 0.05-15.0 ng mL(-1) with a determination coefficient (R-2) of 0.9940, 0.9951, 0.9939, and 0.9946, for the determination of AZI, DOX, AMO, and TC in water samples, respectively. LODs and LOQs were in the range of 0.003-0.015 and 0.01-0.05 ng mL(-1) to determine the analytes, respectively. Intra-day RSDs of the method (n = 5) for the determination of AZI, DOX, AMO, and TC with a concentration of 1.0 ng mL(-1) in water samples were 3.63, 3.49, 3.91, and 3.50%, respectively. Analysis of real samples such as urine and hair samples indicated that the proposed method has proper recoveries in the range of 86.0-101.4% with a relative standard deviation in the range of 3.76-5.36%.
引用
收藏
页码:901 / 911
页数:11
相关论文
共 50 条
  • [21] Acrylamide-functionalized graphene micro-solid-phase extraction coupled to high-performance liquid chromatography for the online analysis of trace monoamine acidic metabolites in biological samples
    Yang, Xiaoting
    Hu, Yufei
    Li, Gongke
    Zhang, Zhuomin
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (08) : 1380 - 1387
  • [22] Simultaneous determination of four aflatoxins using dispersive micro solid phase extraction with magnetic bimetallic MOFs composite as a sorbent and high-performance liquid chromatography with fluorescence detection
    Rezaei, Faezeh
    Masrournia, Mahboubeh
    Pordel, Mehdi
    MICROCHEMICAL JOURNAL, 2023, 189
  • [23] Preconcentration and determination of high leachable pesticides residues in water using solid-phase extraction coupled with high-performance liquid chromatography
    Al-Degs, Yahya S.
    Al-Ghouti, Mohammad A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (07) : 487 - 498
  • [24] Magnetic Solid-Phase Extraction and Ionic Liquid Dispersive Liquid–Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Hexachlorophene in Cosmetics
    Ruiqi Liu
    Ye Liu
    Chunsheng Cheng
    Yaling Yang
    Chromatographia, 2017, 80 : 783 - 791
  • [25] Computational design and fabrication of core-shell magnetic molecularly imprinted polymer for dispersive micro-solid-phase extraction coupled with high-performance liquid chromatography for the determination of rhodamine 6G
    Xie, Jin
    Xie, Jie
    Deng, Jian
    Fang, Xiangfang
    Zhao, Haiqing
    Qian, Duo
    Wang, Hongjuan
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (12) : 2422 - 2430
  • [26] Simultaneous determination of four antibiotics in human urine and hair samples employing a simple and efficient dispersive micro solid-phase extraction-high performance liquid chromatography
    Soleimanirad, Ehsan
    Badameh, Anousheh
    Raoufi, Arastou
    Ebrahimi, Mahmoud
    PHARMACOLOGICAL REPORTS, 2022, 74 (05) : 1069 - 1082
  • [27] Simultaneous determination of four antibiotics in human urine and hair samples employing a simple and efficient dispersive micro solid-phase extraction-high performance liquid chromatography
    Ehsan Soleimanirad
    Anousheh Badameh
    Arastou Raoufi
    Mahmoud Ebrahimi
    Pharmacological Reports, 2022, 74 : 1069 - 1082
  • [28] Magnetic solid phase extraction followed by high-performance liquid chromatography for the determination of sulphonamides in milk samples
    Ibarra, Israel S.
    Miranda, Jose M.
    Rodriguez, Jose A.
    Nebot, Carolina
    Cepeda, Alberto
    FOOD CHEMISTRY, 2014, 157 : 511 - 517
  • [29] Separation and Determination of Paraquat and Diquat in Human Plasma and Urine by Magnetic Dispersive Solid Phase Extraction Coupled with High-Performance Liquid Chromatography
    Sha, Ou
    Cui, Bowen
    Chen, Xiaobing
    Liu, Hua
    Yao, Jiawei
    Zhu, Yuqing
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2020, 2020
  • [30] Magnetic Solid-Phase Extraction and Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Hexachlorophene in Cosmetics
    Liu, Ruiqi
    Liu, Ye
    Cheng, Chunsheng
    Yang, Yaling
    CHROMATOGRAPHIA, 2017, 80 (05) : 783 - 791