Accuracy considerations in navigated cup placement for total hip arthroplasty

被引:14
作者
Langlotz, U.
Gr tzner, P. A.
Bernsmann, K.
Kowal, J. H.
Tannast, M.
Caversaccio, M.
Nolte, L-P
机构
[1] Inst Surg Technol & Biomech, MEM Res Ctr, CH-3014 Bern, Switzerland
[2] mNemosci, Ubach Palenberg, Germany
[3] Katharinen Hosp, Stuttgart, Germany
[4] ViaSana Clin, AA Mill, Netherlands
[5] Univ Bern, Inselspital, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
[6] Univ Bern, Inselspital, Dept ENT Surg, CH-3010 Bern, Switzerland
关键词
accuracy; cup placement; THR; navigation; CT-free; fluoroscopy;
D O I
10.1243/09544119JEIM280
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computer assisted orthopaedic surgery (CAOS) technology has recently been introduced to overcome problems resulting from acetabular component malpositioning in total hip arthroplasty. Available navigation modules can conceptually be categorized as computer tomography (CT) based, fluoroscopy based, or image-free. The current study presents a comprehensive accuracy analysis on the computer assisted placement accuracy of acetabular cups. It combines analyses using mathematical approaches, in vitro testing environments, and an in vivo clinical trial. A hybrid navigation approach combining image-free with fluoroscopic technology was chosen as the best compromise to CT-based systems. It introduces pointer-based digitization for easily assessable points and bi-planar fluoroscopy for deep-seated landmarks. From the in vitro data maximum deviations were found to be 3.6 degrees for inclination and 3.8 degrees for anteversion relative to a pre-defined test position. The maximum difference between intraoperatively calculated cup inclination and anteversion with the postoperatively measured position was 4 degrees and 5 degrees, respectively. These data coincide with worst cases scenario predictions applying a statistical simulation model. The proper use of navigation technology can reduce variability of cup placement well within the surgical safe zone. Surgeons have to concentrate on a variety of error sources during the procedure, which may explain the reported strong learning curves for CAOS technologies.
引用
收藏
页码:739 / 753
页数:15
相关论文
共 50 条
[41]   Achieving Precise Cup Positioning in Direct Anterior Total Hip Arthroplasty: A Narrative Review [J].
Streck, Laura Elisa ;
Boettner, Friedrich .
MEDICINA-LITHUANIA, 2023, 59 (02)
[42]   A Specific Anteversion of Cup and Combined Anteversion for Total Hip Arthroplasty Using Lateral Approach [J].
Li, Li ;
Zhang, Yu ;
Lin, Yuan-yuan ;
Li, Zhen-xing ;
Chen, Liang ;
Chen, Dao-sen ;
Fan, Pei .
ORTHOPAEDIC SURGERY, 2020, 12 (06) :1663-1673
[43]   Comparison of Implant Placement Accuracy Between Manual, Robot-Assisted, Computer-Navigated, Augmented Reality Navigated, Patient-Specific Instrumentation, and Accelerometer Navigated Total Hip Arthroplasty: A Systematic Review and Network Meta-Analysis [J].
Miura, Takanori ;
Yamamoto, Norio ;
Shiroshita, Akihiro ;
Tsuge, Takahiro ;
Saitsu, Akihiro ;
Yoshitani, Junya ;
Nakao, Shuri ;
Takami, Ken .
JBJS REVIEWS, 2024, 12 (11)
[44]   Use of Computer Navigation for Optimal Acetabular Cup Placement in Revision Total Hip Arthroplasty: Case Reports and Surgical Techniques [J].
Neitzke, Anna Colin C. ;
Chandi, Sonia K. ;
Gausden, Elizabeth B. ;
Debbi, Eytan M. ;
Sculco, Peter K. ;
Chalmers, Brian P. .
ARTHROPLASTY TODAY, 2024, 27
[45]   Computer-Assisted Total Hip Arthroplasty Improves Acetabular Prosthesis Placement Accuracy: A Multicenter, Randomized Controlled Clinical Study [J].
Zhou, Ge ;
Geng, Xiao ;
Zhang, Ming ;
Sun, Zhiwen ;
Li, Feng ;
Zhao, Minwei ;
Tian, Hua .
ORTHOPAEDIC SURGERY, 2024, 16 (12) :3078-3087
[46]   The Accuracy of Preoperative Templating in Cementless Total Hip Arthroplasty [J].
Unnanuntana, Aasis ;
Wagner, Dominic ;
Goodman, Stuart B. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (02) :180-186
[47]   Augmented Reality for Acetabular Component Placement in Direct Anterior Total Hip Arthroplasty [J].
Alexander, Clayton ;
Loeb, Alexander E. ;
Fotouhi, Javad ;
Navab, Nassir ;
Armand, Mehran ;
Khanuja, Harpal S. .
JOURNAL OF ARTHROPLASTY, 2020, 35 (06) :1636-+
[48]   A new accelerometer-based portable navigation system provides high accuracy of acetabular cup placement in total hip arthroplasty in both the lateral decubitus and supine positions [J].
Ohyama, Yohei ;
Sugama, Ryo ;
Kim, Yuha ;
Ohta, Yoichi ;
Minoda, Yukihide ;
Nakamura, Hiroaki .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) :4473-4480
[49]   A new accelerometer-based portable navigation system provides high accuracy of acetabular cup placement in total hip arthroplasty in both the lateral decubitus and supine positions [J].
Yohei Ohyama ;
Ryo Sugama ;
Yuha Kim ;
Yoichi Ohta ;
Yukihide Minoda ;
Hiroaki Nakamura .
Archives of Orthopaedic and Trauma Surgery, 2023, 143 :4473-4480
[50]   Changes in leg length and hip offset in navigated imageless vs. conventional total hip arthroplasty [J].
Laggner, Roberta ;
Oktarina, Anastasia ;
Windhager, Reinhard ;
Bostrom, Mathias P. G. .
SCIENTIFIC REPORTS, 2023, 13 (01)