Trueness and marginal fit of implant-supported complete-arch fixed prosthesis frameworks made of high-performance polymers and titanium: An explorative in-vitro study

被引:18
作者
Abou-Ayash, Samir [1 ]
Schimmel, Martin [2 ,3 ]
Ozcan, Mutlu [4 ]
Ozcelik, Burak [5 ]
Bragger, Urs [6 ]
Yilmaz, Burak [7 ,8 ,9 ]
机构
[1] Univ Bern, Sect Digital Implant & Reconstruct Dent, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3007 Bern, Switzerland
[2] Univ Bern, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3007 Bern, Switzerland
[3] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[4] Univ Zurich, Div Dent Biomat, Ctr Dent, Clin Reconstruct Dent, Zurich, Switzerland
[5] Baskent Univ, Fac Dent, Dept Prosthodont, Zurich, Switzerland
[6] Univ Bern, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3007 Bern, Switzerland
[7] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3007 Bern, Switzerland
[8] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Freiburgstr 7, CH-3007 Bern, Switzerland
[9] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH 43210 USA
关键词
Trueness; Marginal fit; CAD-CAM; Fit analysis; PEEK; PEKK; High-performance polymers; DENTAL PROSTHESES; DENTISTRY; CAD/CAM; PEEK; FABRICATION;
D O I
10.1016/j.jdent.2021.103784
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To investigate the trueness and marginal fit of computer-aided design-computer-aided manufactured (CAD-CAM) complete-arch implant-supported screw-retained fixed prosthesis (CAISFP) made of polyetheretherketone (PEEK), polyetherketoneketone (PEKK) and titanium (Ti) Material and methods: A typodont model with four implants, their multiunit abutments (MUAs), and MUA scanbodies were digitized by using a laboratory scanner. The generated CAD was used to mill CAISFP frameworks in Ti, PEEK, or PEKK (each n = 10). The frameworks were digitized with an industrial light scanner to superimpose resulting standard tessellation language (STL) file with the CAD file. Deviations at five points at the abutment-framework interface of each of the four abutment sites (1:left first molar, 2:left canine, 3:right canine, 4:right first molar sites) were calculated (trueness). Marginal gaps were measured using the triple scan technique. A nonparametric repeated measures ANOVA by Brunner and Puri with factors being abutment location and material was performed to assess the mean deviations for trueness and mean marginal gaps, followed by MannWhitney or exact Wilcoxon Signed-Rank tests (alpha=.05). Results: Material type significantly affected the trueness (p<0.0001). PEEK had the lowest deviations (0.039 +/-0.01mm) followed by PEKK (0,049 +/-0.009mm), and Ti (0.074 +/-0.011mm). For marginal gaps, only abutment location's effect was significant (p = 0.003). Within PEKK, gaps at abutment 4 were significantly larger, compared with abutments 2 (p = 0.04) and 3 (p = 0.02). Conclusions: The trueness of PEEK, PEKK, and Ti frameworks was different after milled. PEEK had the highest trueness. However, the marginal fit of the frameworks was similar and smaller than 90 mu m in average. Clinical Relevance: PEEK, PEKK, and Ti complete-arch frameworks had clinically acceptable gaps and may therefore be recommended when their fit is considered. Higher trueness after milling did not result in better marginal fit.
引用
收藏
页数:8
相关论文
共 49 条
  • [1] Fit of CAD/CAM Implant Frameworks: A Comprehensive Review
    Abduo, Jaafar
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 758 - 766
  • [2] In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants
    AL-Meraikhi, Hadi
    Yilmaz, Burak
    McGlumphy, Edwin
    Brantley, William
    Johnston, William M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03) : 409 - 416
  • [3] AL-Meraikhi H, 2018, J PROSTHET DENT, V119, P116, DOI 10.1016/j.prosdent.2017.02.003
  • [4] PEEK High Performance Polymers: A Review of Properties and Clinical Applications in Prosthodontics and Restorative Dentistry
    Alexakou, Elli
    Damanaki, Marianna
    Zoidis, Panagiotis
    Bakiri, Eleonora
    Mouzis, Nikolaos
    Smidt, Greta
    Kourtis, Stefanos
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2019, 27 (03) : 113 - 121
  • [5] Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses
    Alqurashi, Hatim
    Khurshid, Zohaib
    Syed, Azeem Ul Yaqin
    Habib, Syed Rashid
    Rokaya, Dinesh
    Zafar, Muhammad Sohail
    [J]. JOURNAL OF ADVANCED RESEARCH, 2021, 28 : 87 - 95
  • [6] Fatigue behavior and damage modes of high performance poly-ether-ketone-ketone PEKK bilayered crowns
    Alsadon, Omar
    Wood, Duncan
    Patrick, David
    Pollington, Sarah
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 110
  • [7] The influence of prosthetic material on implant and prosthetic survival of implant-supported fixed complete dentures: a systematic review and meta-analysis
    Bagegni, Aimen
    Abou-Ayash, Samir
    Ruecker, Gerta
    Algarny, Ahmad
    Att, Wael
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (03) : 251 - 265
  • [8] The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans
    Cakmak, Gulce
    Yilmaz, Hakan
    Trevino, Alejandro
    Kokat, Ali Murat
    Yilmaz, Burak
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 533 - 541
  • [9] A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK
    Chen, Xin
    Mao, Bochun
    Zhu, Zhuoli
    Yu, Jiayi
    Lu, Yuqing
    Zhang, Qianqian
    Yue, Li
    Yu, Haiyang
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Polyetherketoneketone (PEKK), a framework material for complete fixed and removable dental prostheses: A clinical report
    Dawson, Jonathan H.
    Hyde, Bart
    Hurst, Mitch
    Harris, Bryan T.
    Lin, Wei-Shao
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (06) : 867 - 872