Cloud point extraction for the determination of lead and cadmium in urine by graphite furnace atomic absorption spectrometry with multivariate optimization using Box-Behnken design

被引:61
作者
Maranhao, Tatiane de A.
Martendal, Edmar
Borges, Daniel L. G.
Carasek, Eduardo
Weiz, Bernhard
Curtius, Adilson J. [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Anal, BR-40170 Salvador, BA, Brazil
关键词
cloud point extraction; graphite furnace atomic absorption spectrometry; urine; cadmium determination; lead determination; permanent modifier;
D O I
10.1016/j.sab.2007.05.008
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Cloud point extraction (CPE) is proposed as a pre-concentration procedure for the determination of Pb and Cd in undigested urine by graphite furnace atomic absorption spectrometry (GF AAS). Aliquots of 0.5 mL urine were acidified with HCl and the chelating agent ammonium O,O-diethyl dithiophosphate (DDTP) was added along with the non-ionic surfactant Triton X-1 14 at the optimized concentrations. Phase separation was achieved by heating the mixture to 50 degrees C for 15 min. The surfactant-rich phase was analyzed by GF AAS, employing the optimized pyrolysis temperatures of 900 degrees C for Ph and 800 degrees C for Cd, using a graphite tube with a platform treated with 500 mu g Ru as permanent triodifier. The reagent concentrations for CPE (HCl, DDTP and Triton X-114) were optimized using a Box-Belinken design. The response surfaces and the optimum values were very similar for aqueous solutions and for the urine samples, demonstrating that aqueous standards submitted to CPE could be used for calibration. Detection limits of 40 and 2 ng L-1 for Ph and Cd, respectively, were obtained along with an enhancement factor of 16 for both analytes. Three control urine samples were analyzed using this approach, and good agreement was obtained at a 95% statistical confidence level between the certified and determined values. Five real samples have also been analyzed before and after spiking with Ph and Cd, resulting in recoveries ranging from 97 to 118% (C) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:1019 / 1027
页数:9
相关论文
共 22 条
[1]   Cloud point extraction spectrophotometric determination of trace quantities of bismuth in urine [J].
Afkhami, Abbas ;
Madrakian, Tayyebeh ;
Siampour, Hajar .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (04) :797-802
[2]   Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers [J].
Andrada, D ;
Pinto, FG ;
Magalhaes, CG ;
Nunes, BR ;
Franco, MB ;
da Silva, JBB .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (02) :328-332
[3]   Application of Box-Behnken design and response surface methodology for modeling of some Turkish coals [J].
Aslan, N. ;
Cebeci, Y. .
FUEL, 2007, 86 (1-2) :90-97
[4]   Statistical design-principal component analysis optimization of a multiple response procedure using cloud point extraction and simultaneous determination of metals by ICPOES [J].
Bezerra, Marcos A. ;
Bruns, Roy E. ;
Ferreira, Sergio L. C. .
ANALYTICA CHIMICA ACTA, 2006, 580 (02) :251-257
[5]   Feasibility of employing permanent chemical modifiers for the determination of cadmium in coal using slurry sampling electrothermal atomic absorption spectrometry [J].
Bianchin, L ;
Nadvorny, D ;
da Silva, AF ;
Vale, MGR ;
da Silva, MM ;
dos Santos, WNL ;
Ferreira, SLC ;
Welz, B ;
Heitmann, U .
MICROCHEMICAL JOURNAL, 2006, 82 (02) :174-182
[6]   Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling [J].
Borges, Daniel L. Gallindo ;
da Silva, Alessandra Furtado ;
Welz, Bernhard ;
Curtius, Adilson J. ;
Heitmann, Uwe .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (08) :763-769
[7]   Cloud-point extraction for the determination of Cd, Pb and Pd in blood by electrothermal atomic absorption spectrometry, using Ir or Ru as permanent modifiers [J].
Borges, DLG ;
da Veiga, MAMS ;
Frescura, VLA ;
Welz, B ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :501-507
[8]   Multielement determination of cadmium and lead in urine by simultaneous electrothermal atomic absorption spectrometry with an end-capped graphite tube [J].
Correia, PRM ;
Nomura, CS ;
Oliveira, PV .
ANALYTICAL SCIENCES, 2003, 19 (11) :1519-1523
[9]   Determination of cadmium in biological samples solubilized with tetramethylammonium hydroxide by electrothermal atomic absorption spectrometry, using ruthenium as permanent modifier [J].
da Silva, JBB ;
Borges, DLG ;
Andréia, M ;
da Veiga, MS ;
Curtius, AJ ;
Welz, B .
TALANTA, 2003, 60 (05) :977-982
[10]  
da Silva MAM, 2001, SPECTROCHIM ACTA B, V56, P1941