Effect site concentration during propofol TCI sedation: a comparison of sedation score with two pharmacokinetic models

被引:65
作者
Barakat, A. R.
Sutcliffe, N.
Schwab, M.
机构
[1] Univ Glasgow, Golden Jubilee Natl Hosp, Clydebank G81 4HX, Scotland
[2] Univ Glasgow, Glasgow Royal Infirm, Univ Dept Anaesthesia, Glasgow G31 2ER, Lanark, Scotland
关键词
BISPECTRAL INDEX; PREDICTS LOSS; MIDAZOLAM; CONSCIOUSNESS; VOLUNTEERS; INFUSION;
D O I
10.1111/j.1365-2044.2007.05059.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Target controlled infusion (TCI) pumps function using a programme based on a pharmacokinetic/pharmacodynamic model. We compared the Marsh and Schnider models to find out which better correlates with the clinically observed effect of propofol as assessed by the Observer Assessment of Alertness/Sedation (OAAS) score and the Bispectral index. We assessed the sedation score and Bispectral index score in 40 un-premedicated patients undergoing surgical procedures under spinal anaesthesia with propofol sedation to a target concentration of 2 mu g.ml(-1). Half of the patients received TCI propofol driven by the Schnider model in effect site control, the other half were sedated with TCI propofol driven by the Marsh model in plasma control. We calculated the effect site concentration predicted by both models for all the patients. Changes in the sedation score and Bispectral index correlated better with the Marsh than with the Schnider effect site prediction in both study groups.
引用
收藏
页码:661 / 666
页数:6
相关论文
共 15 条
  • [1] CHERNIK DA, 1990, J CLIN PSYCHOPHARM, V10, P244
  • [2] Automated responsiveness test (ART) predicts loss of consciousness and adverse physiologic responses during propofol conscious sedation
    Doufas, AG
    Bakhshandeh, M
    Bjorksten, AR
    Greif, R
    Sessler, DI
    [J]. ANESTHESIOLOGY, 2001, 94 (04) : 585 - 592
  • [3] Engbers F, 2003, ADV EXP MED BIOL, V523, P3
  • [4] Precision and bias of target controlled propofol infusion for sedation
    Frölich, MA
    Dennis, DM
    Shuster, JA
    Melker, RJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (04) : 434 - 437
  • [5] Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers
    Glass, PS
    Bloom, M
    Kearse, L
    Rosow, C
    Sebel, P
    Manberg, P
    [J]. ANESTHESIOLOGY, 1997, 86 (04) : 836 - 847
  • [6] GREENWALD S, 1994, ANESTHESIOLOGY, V81, pA477
  • [7] Kim DW, 2001, ANESTH ANALG, V93, P1170
  • [8] Electroencephalogram bispectral analysis predicts the depth of midazolam-induced sedation
    Liu, J
    Singh, H
    White, PF
    [J]. ANESTHESIOLOGY, 1996, 84 (01) : 64 - 69
  • [9] PHARMACOKINETIC MODEL DRIVEN INFUSION OF PROPOFOL IN CHILDREN
    MARSH, B
    WHITE, M
    MORTON, N
    KENNY, GNC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (01) : 41 - 48
  • [10] Relationship between, bispectral index, auditory evoked potential index and effect-site EC50 for propofol at two clinical end-points
    Milne, SE
    Troy, A
    Irwin, MG
    Kenny, GNC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (02) : 127 - 131