Healing of Aneurysm after Treatment Using Flow Diverter Stent : Histopathological Study in Experimental Canine Carotid Side Wall Aneurysm

被引:8
作者
Lee, Jong Young [1 ]
Cho, Young Dae [2 ]
Kang, Hyun-Seung [3 ]
Han, Moon Hee [4 ]
机构
[1] Hallym Univ, Coll Med, Gangdong Sacred Heart Hosp, Dept Neurosurg, Seoul, South Korea
[2] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Neurosurg, Seoul, South Korea
[4] Vet Hlth Serv Med Ctr, Dept Neurosurg, 53 Jinhwangdo Ro 61 Gil, Seoul 05368, South Korea
关键词
Canine; Aneurysm; Flow; Diversion; Stents; Histology; PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; SACCULAR ANEURYSMS; ARTERY; HEMODYNAMICS; OCCLUSION; 2ND-GENERATION; EXPERIENCE; NEOINTIMA; POROSITY;
D O I
10.3340/jkns.2019.0067
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : Despite widespread use of flow diverters (FDs) to treat aneurysms, the exact healing mechanism associated with FDs remains poorly understood. We aim to describe the healing process of aneurysms treated using FDs by demonstrating the histopathologic progression in a canine aneurysm model. Methods : Twenty-one side wall aneurysms were created in common carotid artery of eight dogs and treated with two different FDs. Angiographic follow-ups were done immediately after placement of the device, 4 weeks and 12 weeks. At last follow-up, the aneurysm and the device-implanted parent artery were harvested. Results : Histopathologic findings of aneurysms at 4 weeks follow-up showed intra-aneurysm thrombus formation in laminating fashion, and neointimal thickening at the mid-segment of aneurysm. However, there are inhomogenous findings in aneurysms treated with the same type of FD showing same angiographic outcomes. At 12 weeks, aneurysms of complete and near-complete occlusion revealed markedly shrunken aneurysm filled with organized connective tissues with thin neointima. Aneurysms of incomplete occlusion at 12 weeks showed small amount of organized thrombus around fringe neck and large empty space with thick neointmal formation. Neointimal thickness and diameter stenosis was not significantly different between the groups of FD specification and follow-up period. Conclusion : Intra-aneurysmal thrombus formation and organization seem to be an important factor for the complete occlusion of aneurysms treated using the FD. Neointimal formation could occur along the struts of the FD independently of intra-aneurysmal thrombus formation. However, neointimal formation could not solely lead to complete aneurysm healing.
引用
收藏
页码:34 / 44
页数:11
相关论文
共 29 条
[1]   Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis [J].
Arrese, Ignacio ;
Sarabia, Rosario ;
Pintado, Rebeca ;
Delgado-Rodriguez, Miguel .
NEUROSURGERY, 2013, 73 (02) :193-199
[2]  
Augsburger L, 2009, CLIN NEURORADIOL, V19, P204, DOI 10.1007/s00062-009-9005-0
[3]   Endovascular coiling of proximal middle cerebral artery aneurysms: is it safe and durable? [J].
Baek, Jin Wook ;
Huh, Chae Wook ;
Heo, Young Jin ;
Yoo, Min Wook ;
Kwon, Soon Chan ;
Kwon, O. Ki ;
Jeong, Hae Woong ;
Kim, Sung Tae ;
Jin, Sung-Chul .
ACTA NEUROCHIRURGICA, 2018, 160 (12) :2411-2418
[4]   Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics:: flow quantification in elastic sidewall aneurysm models [J].
Baráth, K ;
Cassot, F ;
Fasel, JHD ;
Ohta, M ;
Rüfenacht, DA .
NEUROLOGICAL RESEARCH, 2005, 27 :S120-S128
[5]   In Vivo Experimental Intracranial Aneurysm Models: A Systematic Review [J].
Bouzeghrane, F. ;
Naggara, O. ;
Kallmes, D. F. ;
Berenstein, A. ;
Raymond, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (03) :418-423
[6]   Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications-a retrospective data analysis [J].
Briganti, Francesco ;
Napoli, Manuela ;
Tortora, Fabio ;
Solari, Domenico ;
Bergui, Mauro ;
Boccardi, Edoardo ;
Cagliari, Enrico ;
Castellan, Lucio ;
Causin, Francesco ;
Ciceri, Elisa ;
Cirillo, Luigi ;
De Blasi, Roberto ;
Delehaye, Luigi ;
Di Paola, Francesco ;
Fontana, Andrea ;
Gasparotti, Roberto ;
Guidetti, Giulio ;
Divenuto, Ignazio ;
Iannucci, Giuseppe ;
Isalberti, Maurizio ;
Leonardi, Marco ;
Lupo, Fernando ;
Mangiafico, Salvatore ;
Manto, Andrea ;
Menozzi, Roberto ;
Muto, Mario ;
Nuzzi, Nunzio Paolo ;
Papa, Rosario ;
Petralia, Benedetto ;
Piano, Mariangela ;
Resta, Maurizio ;
Padolecchia, Riccardo ;
Saletti, Andrea ;
Sirabella, Giovanni ;
Bolge, Luca Piero Valvassori .
NEURORADIOLOGY, 2012, 54 (10) :1145-1152
[7]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[8]   Analysis of Hemodynamics and Aneurysm Occlusion after Flow-Diverting Treatment in Rabbit Models [J].
Cebral, J. R. ;
Mut, F. ;
Raschi, M. ;
Hodis, S. ;
Ding, Y. -H. ;
Erickson, B. J. ;
Kadirvel, R. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (08) :1567-1573
[9]  
Chan T. T., 2011, Hong Kong Medical Journal, V17, P398
[10]   The Use of Flow-Diverting Stents in the Treatment of Giant Cerebral Aneurysms: Preliminary Results [J].
Cirillo, L. ;
Dall'Olio, M. ;
Princiotta, C. ;
Simonetti, L. ;
Stafa, A. ;
Toni, F. ;
Leonardi, M. .
NEURORADIOLOGY JOURNAL, 2010, 23 (02) :220-224