A novel method for the prediction of functional biological activity of polyethylene wear debris

被引:87
作者
Fisher, J [1 ]
Bell, J
Barbour, PSM
Tipper, JL
Matthews, JB
Besong, AA
Stone, MH
Ingham, E
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Sch Biochem & Mol Biol, Leeds LS2 9JT, W Yorkshire, England
[3] Gen Infirm, Dept Orthopaed Surg, Leeds LS1 3EX, W Yorkshire, England
关键词
joint replacement; polyethylene; wear debris; functional biological activity; model;
D O I
10.1243/0954411011533599
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The comparative performance of artificial hip joints has been extensively investigated in vitro through measurements of wear volumes. In vivo a major cause of long-term failure is wear-debris-induced osteolysis. These adverse biological reactions are not simply dependent on wear volume, but are also controlled by the size and volumetric concentration of the debris. A novel model is presented which predicts functional biological activity; this is determined by integrating the product of the biological activity function and the volumetric concentration function with the wear volume over the whole particle size range. This model combines conventional wear volume measurements with particle analysis and the output from in vitro, cell culture studies to provide a new indicator of osteolytic potential. The application of the model is demonstrated through comparison of the functional biological activity of wear debris from polyethylene acetabular cups articulating under three different conditions in a hip joint simulator.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 18 条
[1]   Mixed oxides prosthetic ceramic ball heads.: Part 1:: effect of the ZrO2 fraction on the wear of ceramic on polyethylene joints [J].
Affatato, S ;
Testoni, M ;
Cacciari, GL ;
Toni, A .
BIOMATERIALS, 1999, 20 (10) :971-975
[2]   A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H6) :569-576
[3]   Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation [J].
Besong, AA ;
Tipper, JL ;
Ingham, E ;
Stone, MH ;
Wroblewski, BM ;
Fisher, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :340-344
[4]  
BESONG AA, 1999, P IMECHE C KNEE REPL, P70
[5]  
ENDO MM, 2001, IN PRESS BIOMED MAT
[6]  
FISHER J, 2000, P 46 ANN M ORTH RES, P589
[7]  
Goodman SB, 1996, J BIOMED MATER RES, V31, P421, DOI 10.1002/(SICI)1097-4636(199607)31:3<421::AID-JBM17>3.0.CO
[8]  
2-L
[9]   Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro [J].
Green, TR ;
Fisher, J ;
Stone, M ;
Wroblewski, BM ;
Ingham, E .
BIOMATERIALS, 1998, 19 (24) :2297-2302
[10]   Biological reactions to wear debris in total joint replacement [J].
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :21-37