Recent developments in potentiometric biosensors for biomedical analysis

被引:98
作者
Koncki, Robert [1 ]
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
关键词
clinical analysis; potentiometry; biosensors; biocatalysis; bioaffinity;
D O I
10.1016/j.aca.2007.08.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A large variety of potentiometric biosensors is developed using biocatalytic and bioaffinity-based biosensing schemes. However, only few of them could be applied for the biomedical analysis. The most promising are those for the detection of main products of protein metabolism, namely urea and creatinine. A novel group of potentiometric biosensors is constituted by bioaffinity-based devices that could be used for immunoassays or genoanalysis. This paper reviews the recent trends in these fields as well as discusses advantages, limitations and pitfalls of the developed biosensors. Some potentiometric biosensors useful for real biomedical analysis are reported in detail. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 15
页数:9
相关论文
共 52 条
[1]   Solid state potentiometric sensor for the estimation of tributyrin and urea [J].
Basu, I ;
Subramanian, RV ;
Mathew, A ;
Kayastha, AM ;
Chadha, A ;
Bhattacharya, E .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (01) :418-423
[2]   Modification of ISFETs with a monolayer of latex beads for specific detection of proteins [J].
Besselink, GAJ ;
Schasfoort, RBM ;
Bergveld, P .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (09) :1109-1114
[3]   Portable urea biosensor based on the extended-gate field effect transistor [J].
Chen, JC ;
Chou, JC ;
Sun, TP ;
Hsiung, SK .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) :180-186
[4]   Potentiometric biosensing of proteins with ultrasensitive ion-selective microelectrodes and nanoparticle labels [J].
Chumbimuni-Torres, Karin Y. ;
Dai, Zong ;
Rubinova, Nastassia ;
Xiang, Yun ;
Pretsch, Erno ;
Wang, Joseph ;
Bakker, Eric .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (42) :13676-13677
[5]   Construction of a potentiometric biosensor for monitoring urea during peritoneal dialysis [J].
Cunningham, DD .
SENSOR LETTERS, 2004, 2 (3-4) :217-220
[6]   Improved performance of the potentiometric biosensor for the determination of creatinine [J].
Dallerup Rasmussen, Claus ;
Andersen, Jens E. T. ;
Zachau-Christiansen, Birgit .
ANALYTICAL LETTERS, 2007, 40 (01) :39-52
[7]  
DIAZGONZALEZ M, 2007, ELECTROANAL, V79, P5107
[8]   Study on the immobilization of anti-IgG on Au-colloid modified gold electrode via potentiometric immunosensor, cyclic voltammetry, and electrochemical impedance techniques [J].
Fu, YZ ;
Yuan, R ;
Tang, DP ;
Chai, YQ ;
Xu, L .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2005, 40 (01) :61-66
[9]   Potentiometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples [J].
Gutierrez, Manuel ;
Alegret, Salvador ;
del Valle, Martel .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :2171-2178
[10]   A novel enzyme immunoassay based on potentiometric measurement of molecular adsorption events by an extended-gate field-effect transistor sensor [J].
Kamahori, Masao ;
Ishige, Yu ;
Shimoda, Maki .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :3080-3085