W-shaped volume curve with gated myocardial perfusion single photon emission computed tomography

被引:5
作者
Kasai, T [1 ]
DePuey, EG [1 ]
Sponder, I [1 ]
机构
[1] Columbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USA
关键词
gating errors; myocardial SPECT; left ventricular function; volume curve; time-activity curve;
D O I
10.1007/BF02986338
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Gating errors (GEs) with ECG gated myocardial SPECT (G-SPECT) may occur irrespective of the presence or absence of arrhythmias. We evaluated the impact of GEs on both reconstructed tomograms and left ventricular ejection fraction (LVEF) derived from G-SPECT, and searched for clues to identify these errors. Methods: We studied 2 GE patients, 10 normal subjects (NLs), and 10 atrial fibrillation patients. Stress technetium-99m sestamibi G-SPECT was performed. Left ventricular (LV) contraction was evaluated in the beating slices. LVEF was calculated with G-SPECT using QGS (Cedars-Sinai, Los Angels) and p-FAST (Sapporo Medical University, Japan), and compared with that obtained by echocardiography (ECHO). LV volume curves were created by QGS and p-FAST. ne heart rates (HRs) were calculated from the acquired images, and compared with their resting HRs. The mean count density of the myocardium was measured and time-activity curves were created. Results: In patients with GEs, bi-phasic LV contraction was demonstrated with fading-out towards end-diastole. G-SPECT underestimated LVEF compared to ECHO by 10% or more. The volume curves appeared "W-shaped." The HRs from the images were slower than the resting HRs. The count density decrement from frame #1 to #8 was larger than that of NLs. The time-activity curves were different in shape from those of NLs. Conclusions: G-SPECT underestimates LVEF in patients with GEs. These errors can be identified with a combination of visual inspection of beating slices, time-volume curves, and time-activity curves. Monitoring the HR is a clue for anticipating and avoiding these errors.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 17 条
[1]   Artifactual reverse distribution pattern in myocardial perfusion SPECT with technetium-99m sestamibi [J].
Araujo, W ;
DePuey, EG ;
Kamran, M ;
Undavia, M ;
Friedman, M .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (06) :633-638
[2]   The additive value of gated SPET myocardial perfusion imaging in patients with known and suspected coronary artery disease [J].
Bavelaar-Croon, CDL ;
Atsma, DE ;
Van der Wall, EE ;
Dibbets-Schneider, P ;
Zwinderman, AH ;
Pauwels, EKJ .
NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (01) :45-55
[3]  
DEPUEY EG, 1908, DIAGNOSTIC NUCL MED, P355
[4]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[5]  
Feng B, 2002, J NUCL MED, V43, P786
[6]   Reverse redistribution of 99mTc-sestamibi after direct percutaneous transluminal coronary angioplasty in acute myocardial infarction:: relationship with wall motion and functional response to dobutamine stimulation [J].
Fujiwara, S ;
Takeishi, Y ;
Hirono, O ;
Fukui, A ;
Okuyama, M ;
Yamaguchi, S ;
Ito, M ;
Kaneko, K ;
Shishido, T ;
Miyamoto, T ;
Yuki, K ;
Miyashita, T ;
Takahashi, K ;
Minamihaba, O ;
Tomoike, H ;
Yamauchi, S ;
Fatema, K .
NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (11) :1223-1230
[7]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[8]   Impact of gating errors with electrocardiography gated myocardial perfusion SPECT [J].
Kasai, T ;
DePuey, EG ;
Shah, AA ;
Merla, VC .
JOURNAL OF NUCLEAR CARDIOLOGY, 2003, 10 (06) :709-711
[9]   Assessment of myocardial washout of Tc-99m-sestamibi in patients with chronic heart failure: Comparison with normal control [J].
Kumita, S ;
Seino, Y ;
Cho, K ;
Nakajo, H ;
Toba, M ;
Fukushima, Y ;
Okamoto, N ;
Takano, T ;
Kumazaki, T .
ANNALS OF NUCLEAR MEDICINE, 2002, 16 (04) :237-242
[10]   Two- and three-dimensional assessments of myocardial perfusion and function by using technetium-99m sestamibi gated SPECT with a combination of count- and image-based techniques [J].
Nakata, T ;
Katagiri, Y ;
Odawara, Y ;
Eguchi, M ;
Kuroda, M ;
Tsuchihashi, K ;
Hareyama, M ;
Shimamato, K .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (06) :623-632