W-shaped volume curve with gated myocardial perfusion single photon emission computed tomography
被引:5
作者:
Kasai, T
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USAColumbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USA
Kasai, T
[1
]
DePuey, EG
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USAColumbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USA
DePuey, EG
[1
]
Sponder, I
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USAColumbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USA
Sponder, I
[1
]
机构:
[1] Columbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USA
Objectives: Gating errors (GEs) with ECG gated myocardial SPECT (G-SPECT) may occur irrespective of the presence or absence of arrhythmias. We evaluated the impact of GEs on both reconstructed tomograms and left ventricular ejection fraction (LVEF) derived from G-SPECT, and searched for clues to identify these errors. Methods: We studied 2 GE patients, 10 normal subjects (NLs), and 10 atrial fibrillation patients. Stress technetium-99m sestamibi G-SPECT was performed. Left ventricular (LV) contraction was evaluated in the beating slices. LVEF was calculated with G-SPECT using QGS (Cedars-Sinai, Los Angels) and p-FAST (Sapporo Medical University, Japan), and compared with that obtained by echocardiography (ECHO). LV volume curves were created by QGS and p-FAST. ne heart rates (HRs) were calculated from the acquired images, and compared with their resting HRs. The mean count density of the myocardium was measured and time-activity curves were created. Results: In patients with GEs, bi-phasic LV contraction was demonstrated with fading-out towards end-diastole. G-SPECT underestimated LVEF compared to ECHO by 10% or more. The volume curves appeared "W-shaped." The HRs from the images were slower than the resting HRs. The count density decrement from frame #1 to #8 was larger than that of NLs. The time-activity curves were different in shape from those of NLs. Conclusions: G-SPECT underestimates LVEF in patients with GEs. These errors can be identified with a combination of visual inspection of beating slices, time-volume curves, and time-activity curves. Monitoring the HR is a clue for anticipating and avoiding these errors.
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Bavelaar-Croon, CDL
Atsma, DE
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Atsma, DE
Van der Wall, EE
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Van der Wall, EE
Dibbets-Schneider, P
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Dibbets-Schneider, P
Zwinderman, AH
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Zwinderman, AH
Pauwels, EKJ
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Bavelaar-Croon, CDL
Atsma, DE
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Atsma, DE
Van der Wall, EE
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Van der Wall, EE
Dibbets-Schneider, P
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Dibbets-Schneider, P
Zwinderman, AH
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands
Zwinderman, AH
Pauwels, EKJ
论文数: 0引用数: 0
h-index: 0
机构:
Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, NetherlandsLeiden Univ, Med Ctr, Dept Radiol, Div Nucl Med C4Q, NL-2333 ZA Leiden, Netherlands