Minimizing the number of implantation needles for prostate 125I brachytherapy: An investigation of possibilities and implications

被引:8
作者
Steggerda, Marcel J. [1 ]
van der Poel, Henk G. [2 ]
Moonen, Luc M. F. [1 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
[2] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Urol, NL-1066 CX Amsterdam, Netherlands
关键词
Prostate brachytherapy; Implantation needles; Interseed spacing; Seed activity; Puncture trauma; SEED IMPLANTS; URINARY RETENTION; RANDOMIZED-TRIAL; TOXICITY; STRENGTH; CANCER; MORBIDITY; MEN;
D O I
10.1016/j.brachy.2009.07.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Reduction of the number of implantation needles for prostate brachytherapy will shorten the duration of implantation procedures and possibly reduce trauma-related morbidity. The purpose of this study was to investigate possibilities for the minimization of the number of needles and to investigate the consequences for the dose distribution. METHODS AND MATERIALS: A planning study for six different prostate volumes was performed. The number of needles was minimized by changing fixed 1 cm interseed spacing to free interseed spacing within the needles and by increasing the seed activity. Dose volume parameters of prostate and organs at risk (OAR) bladder, rectum, and urethra were determined. For plans with different needle and seed configurations, the sensitivity for random seed placement inaccuracies was tested. Dose distributions of realized implants based on fixed (n = 21) and free interseed spacing (n = 21) were compared. RESULTS: The average number of needles (+/-1 standard deviation) could be reduced from 18.8 +/- 3.6 to 12.7 +/- 2.9 (-33%) when changing from fixed interseed spacing to free interseed spacing and subsequently to 7.3 +/- 1.0 (-42%) by increasing the seed strength from 0.57 U to 1.14 U. These needle reductions resulted in increased dose inhomogeneity within the prostate and increased sensitivity of dose volume parameters of the OAR for random geometrical inaccuracies. Introduction of free interseed spacing in our clinic resulted in very satisfactory dose coverage of the prostate (D-90 = 172 +/- 17 Gy), while the average number of needles was reduced by 30%. CONCLUSIONS: Substantial reduction of the number of implantation needles is possible without compromising adequate dose coverage of the prostate. However, the chance of an unpredicted high dose to the OAR increases as fewer needles are used. (C) 2010 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:319 / 327
页数:9
相关论文
共 22 条
[1]   A prospective analysis of tong-term quality of life after permanent I-125 brachytherapy for locatised prostate cancer [J].
Ash, Dan ;
Bottomley, David ;
Al-Qaisieh, Bashar ;
Carey, Brendan ;
Gould, Kath ;
Henry, Ann .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (02) :135-139
[2]   The robustness of dose distributions to displacement and migration of 125I permanent seed implants over a wide range of seed number, activity, and designs [J].
Beaulieu, L ;
Archambault, L ;
Aubin, S ;
Oral, E ;
Taschereau, R ;
Pouliot, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (04) :1298-1308
[3]   Acute urinary retention after transperineal template-guided prostate biopsy [J].
Buskirk, SJ ;
Pinkstaff, DM ;
Petrou, SP ;
Wehle, MJ ;
Broderick, GA ;
Young, PR ;
Weigand, SD ;
O'Brien, PC ;
Igel, TC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05) :1360-1366
[4]   Effect of low dose-rate prostate brachytherapy on the sexual health of men with optimal sexual function before treatment:: analysis at ≥ 7 years of follow-up [J].
Cesaretti, Jamie A. ;
Kao, Johnny ;
Stone, Nelson N. ;
Stock, Richard G. .
BJU INTERNATIONAL, 2007, 100 (02) :362-367
[5]   Patient and treatment factors associated with complications after prostate brachytherapy [J].
Chen, Aileen B. ;
D'Amico, Anthony V. ;
Neville, Bridget A. ;
Earle, Craig C. .
JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (33) :5298-5304
[6]   Dose homogeneity as a function of source activity in optimized I-125 prostate implant treatment plans [J].
D'Souza, WD ;
Meyer, RR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :1120-1130
[7]   Correlating the degree of needle trauma during prostate brachytherapy and the development of acute urinary toxicity [J].
Eapen, L ;
Kayser, C ;
Deshaies, Y ;
Perry, G ;
Choan, E ;
Morash, C ;
Cygler, JE ;
Wilkins, D ;
Dahrouge, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05) :1392-1394
[8]   Clinical correlates of high intraprostatic brachytherapy dose volumes [J].
Jones, S ;
Wallner, K ;
Merrick, G ;
Corriveau, J ;
Sutlief, S ;
True, L ;
Butler, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02) :328-333
[9]   Factors predicting for postimplantation urinary retention after permanent prostate brachytherapy [J].
Lee, N ;
Wuu, CS ;
Brody, R ;
Laguna, JL ;
Katz, AE ;
Bagiella, E ;
Ennis, RD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1457-1460
[10]   Predictive factors for erectile dysfunction in men with prostate cancer after brachytherapy: Is dose to the penile bulb important? [J].
MacDonald, AG ;
Keyes, M ;
Kruk, A ;
Duncan, G ;
Moravan, V ;
Morris, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01) :155-163