Solid-phase reactors in sequential injection analysis. Determination of manganese(II) in tap water and effluent streams using a solid-phase lead(IV) dioxide reactor in a sequential injection system

被引:10
作者
Naidoo, EB [1 ]
van Staden, JF [1 ]
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 370卷 / 06期
关键词
D O I
10.1007/s002160000527
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of manganese(II) in tap water and effluent streams, using a solid-phase reactor incorporated into a sequential injection system was investigated. Mn2+-ions in samples injected into a carrier stream, were oxidised by solid lead(IV) dioxide suspended on silica gel beads to form MnO4--ions which were detected spectrophotometrically at 526 nm. The linear range of the system is from I to 7 mg L-1 with a detection limit of 0.62 mg L-1. The proposed system is suitable for the determination of manganese(II) in tap and effluent streams at a rate of approximately 50 samples per hour with a relative standard deviation of better than 3%. Statistical comparison between the proposed sequential injection system and a standard ICP method revealed that there is no significant difference between the two methods at the 95% confidence level for effluent streams and at 99.9% for tap water.
引用
收藏
页码:776 / 780
页数:5
相关论文
共 20 条
[1]   SENSITIVE DETERMINATION OF MANGANESE USING FLOW-INJECTION AND CHEMILUMINESCENT DETECTION [J].
BOWIE, AR ;
FIELDEN, PR ;
LOWE, RD ;
SNOOK, RD .
ANALYST, 1995, 120 (08) :2119-2127
[2]  
BURGUERA JL, 1987, FLOW INJECTION ATOMI
[3]   ONLINE SOLID-PHASE REACTORS FOR UNSEGMENTED CONTINUOUS-FLOW DRUG ANALYSIS [J].
CALATAYUD, JM ;
GARCIA, JV .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (10) :428-436
[4]   SOLID-PHASE REACTORS IN FLOW-INJECTION ANALYSIS [J].
DECASTRO, MDL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (04) :149-155
[5]   SELECTIVE STOPPED-FLOW DETERMINATION OF MANGANESE WITH LUMINOL IN THE ABSENCE OF HYDROGEN-PEROXIDE [J].
GAIKWAD, A ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :275-282
[6]  
Griffin A., 1960, Journal American Water Works Association, V52, P1326, DOI [10.1002/j.1551-8833.1960.tb00599.x, DOI 10.1002/J.1551-8833.1960.TB00599.X]
[7]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[8]   Solid-phase sodium bismuthate as an oxidant in flow injection analysis: determination of manganese in effluent streams [J].
Kargosha, K ;
Noroozifar, M .
ANALYTICA CHIMICA ACTA, 2000, 413 (1-2) :57-61
[9]  
Marshall G. D., 1992, PROCESS CONTR QUAL, V3, P251
[10]  
MARSHALL GD, 1992, ANAL INSTRUM, V20, P79