Sensor fault detection and isolation via high-gain observers: Application to a double-pipe heat exchanger

被引:44
作者
Escobar, R. F. [2 ]
Astorga-Zaragoza, C. M. [2 ]
Tellez-Anguiano, A. C. [3 ]
Juarez-Romero, D. [1 ]
Hernandez, J. A. [1 ]
Guerrero-Ramirez, G. V. [2 ]
机构
[1] Univ Autonoma Estado Morelos, Ctr Invest Ingn & Ciencias, Cuernavaca 62209, Morelos, Mexico
[2] Ctr Nacl Invest & Desarrollo Tecnol, Cuernavaca 62490, Morelos, Mexico
[3] Inst Tecnol Morelia, Morelia 58120, Michoacan, Mexico
关键词
FDI; High-gain observers; Heat exchangers; SYSTEMS; DESIGN; MODEL;
D O I
10.1016/j.isatra.2011.03.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper deals with fault detection and isolation (FDI) in sensors applied to a concentric-pipe counter-flow heat exchanger. The proposed FDI is based on the analytical redundancy implementing nonlinear high-gain observers which are used to generate residuals when a sensor fault is presented (as software sensors). By evaluating the generated residual, it is possible to switch between the sensor and the observer when a failure is detected. Experiments in a heat exchanger pilot validate the effectiveness of the approach. The FDI technique is easy to implement allowing the industries to have an excellent alternative tool to keep their heat transfer process under supervision. The main contribution of this work is based on a dynamic model with heat transfer coefficients which depend on temperature and flow used to estimate the output temperatures of a heat exchanger. This model provides a satisfactory approximation of the states of the heat exchanger in order to allow its implementation in a FDI system used to perform supervision tasks. (C) 2011 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:480 / 486
页数:7
相关论文
共 25 条
[1]   NONLINEAR HEAT-EXCHANGER CONTROL THROUGH THE USE OF PARTIALLY LINEARIZED CONTROL VARIABLES [J].
ALSOP, AW ;
EDGAR, TF .
CHEMICAL ENGINEERING COMMUNICATIONS, 1989, 75 :155-170
[2]  
[Anonymous], P 3 IEEE C CONTR APP
[3]  
[Anonymous], P INT S DISTR HEAT S
[4]  
[Anonymous], INT J INFORM SYST SC
[5]  
ANZUREZ MARÍN JUAN, 2009, Dyna rev.fac.nac.minas, V76, P209
[6]   Remarks on nonlinear adaptive observer design [J].
Besançon, G .
SYSTEMS & CONTROL LETTERS, 2000, 41 (04) :271-280
[7]   Multi-linear model-based fault detection during process transitions [J].
Bhagwat, A ;
Srinivasan, R ;
Krishnaswamy, PR .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (09) :1649-1670
[8]  
Chen J, 2012, ROBUST MODEL BASED F
[9]   Modelling and robust FDI of steam generator using uncertain bond graph model [J].
Djeziri, M. A. ;
Bouamama, B. Ould ;
Merzouki, R. .
JOURNAL OF PROCESS CONTROL, 2009, 19 (01) :149-162
[10]   FAULT-DIAGNOSIS IN DYNAMIC-SYSTEMS USING ANALYTICAL AND KNOWLEDGE-BASED REDUNDANCY - A SURVEY AND SOME NEW RESULTS [J].
FRANK, PM .
AUTOMATICA, 1990, 26 (03) :459-474