Cardiac Resynchronization Therapy and Obstructive Sleep-Related Breathing Disorder in Patients with Congestive Heart Failure

被引:4
作者
Shalaby, Alaa [1 ,2 ]
Atwood, Charles W. [1 ,3 ]
Selzer, Faith [4 ]
Suffoletto, Matthew [2 ]
Gorcsan, John, III [2 ]
Strollo, Patrick [3 ]
机构
[1] Vet Affairs Pittsburgh Healthcare Syst, Pittsburgh, PA USA
[2] Univ Pittsburgh, Med Ctr, Div Cardiol, Pittsburgh, PA USA
[3] Univ Pittsburgh, Grad Sch Publ Hlth, Div Pulm Allergy & Crit Care Med, Pittsburgh, PA USA
[4] Univ Pittsburgh, Grad Sch Publ Hlth, Epidemiol Data Ctr, Pittsburgh, PA USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2011年 / 34卷 / 05期
关键词
congestive heart failure; CRT; pacing; POSITIVE AIRWAY PRESSURE; CHEYNE-STOKES RESPIRATION; RESYNCHRONISATION THERAPY; VENTRICULAR DYSSYNCHRONY; RATE-VARIABILITY; APNEA; TRIAL; DYSFUNCTION; IMPROVEMENT; PREDICTORS;
D O I
10.1111/j.1540-8159.2010.03015.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: CRT may have a positive influence on SRBD in patients who qualify for the therapy. Data are inconclusive in patients with obstructive SRBD. Methods: Consenting patients eligible for CRT underwent a baseline polysomnography (PSG) 2 weeks after implantation during which pacing was withheld. Patients with an apnea hypopnea index (AHI) >= 15 but < 50 were enrolled and randomized to atrial overdrive pacing (DDD) versus atrial synchronous pacing (VDD) with biventricular pacing in both arms. Patients underwent two further PSGs 12 weeks apart. Results: Nineteen men with New York Heart Association class III congestive heart failure participated in the study (age 67.2 +/- 7.5, Caucasian 78.9%, ischemic 73.7%). The score on Epworth Sleepiness Score was 7.3 +/- 4.0, Pittsburgh Sleep Quality Index 7.4 +/- 3.1, and Minnesota Living with Heart Failure Questionnaire 36.9 +/- 21.9. There were no differences between the groups. At baseline, patients exhibited poor sleep efficiency (65.3 +/- 16.6%) with nadir oxygen saturation of 83.5 +/- 5.3% and moderate to severe SRBD (AHI 21.5 +/- 15.3) that was mainly obstructive (central apnea index 3.3 +/- 6.7/hour). On both follow-up assessments, there was no improvement in indices of SRBD (sleep efficiency [68.3 +/- 17.9%], nadir oxygen saturation of 82.8 +/- 4.6%, and AHI 24.9 +/- 21.9). Conclusion: In a cohort of elderly male CHF patients receiving CRT, CRT had no impact on obstructive SRBD burden with or without atrial overdrive pacing. (PACE 2011; 34:593-603).
引用
收藏
页码:593 / 603
页数:11
相关论文
共 41 条
[31]   Atrial overdrive pacing for the obstructive sleep apnea-hypopnea syndrome [J].
Simantirakis, EN ;
Schiza, SE ;
Chrysostomakis, SI ;
Chlouverakis, GI ;
Klapsinos, NC ;
Siafakas, NM ;
Vardas, PE .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (24) :2568-2577
[32]   Cardiac resynchronization therapy improves central sleep apnea and Cheyne-Stokes respiration in patients with chronic heart failure [J].
Sinha, AM ;
Skobel, EC ;
Breithardt, OA ;
Norra, C ;
Markus, KU ;
Breuer, C ;
Hanrath, P ;
Stellbrink, C .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (01) :68-71
[33]   Effect of cardiac resynchronization therapy on sleep quality, quality of life, and symptomatic depression in patients with chronic heart failure and Cheyne-Stokes respiration [J].
Skobel E.C. ;
Sinha A.-M. ;
Norra C. ;
Randerath W. ;
Breithardt O.-A. ;
Breuer C. ;
Hanrath P. ;
Stellbrink C. .
Sleep and Breathing, 2005, 9 (4) :159-166
[34]   Muscle sympathetic nerve activity during wakefulness in heart failure patients with and without sleep apnea [J].
Spaak, J ;
Egri, ZJ ;
Kubo, T ;
Yu, E ;
Ando, S ;
Kaneko, Y ;
Usui, K ;
Bradley, TD ;
Floras, JS .
HYPERTENSION, 2005, 46 (06) :1327-1332
[35]   Sleep apnoea as a predictor of mid- and long-term outcome in patients undergoing cardiac resynchronization therapy [J].
Sredniawa, Beata ;
Lenarczyk, Radoslaw ;
Kowalski, Oskar ;
Pruszkowska-Skrzep, Patrycja ;
Kowalczyk, Jacek ;
Musialik-Lydka, Agata ;
Cebula, Sylwia ;
Kalarus, Zbigniew .
EUROPACE, 2009, 11 (01) :106-114
[36]   The impact of cardiac resynchronization therapy on obstructive sleep apnea in heart failure patients - A pilot study [J].
Stanchina, Michael L. ;
Ellison, Kristin ;
Malhotra, Atul ;
Anderson, Maria ;
Kirk, Malcolm ;
Benser, Michael E. ;
Tosi, Christine ;
Carlisle, Carol ;
Millman, Richard P. ;
Buxton, Alfred .
CHEST, 2007, 132 (02) :433-439
[37]   Sleep apnea in heart failure increases heart rate variability and sympathetic dominance [J].
Szollosi, Irene ;
Krum, Henry ;
Kaye, David ;
Naughton, Matthew T. .
SLEEP, 2007, 30 (11) :1509-1514
[38]  
Voigt Andrew, 2010, Clin Cardiol, V33, pE1, DOI 10.1002/clc.20500
[39]   Alleviation of Pulmonary Hypertension by Cardiac Resynchronization Therapy is Associated with Improvement in Central Sleep Apnea [J].
Yiu, Kai-Hang ;
Lee, Kathy Lai-Fun ;
Lau, Chu-Pak ;
Siu, Chung-Wah ;
Miu, Kin-Man ;
Lam, Bing ;
Lam, Jamie ;
Ip, Mary Sau Man ;
Tse, Hung-Fat .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (12) :1522-1527
[40]   A novel tool to assess systolic asynchrony and identify responders of cardiac resynchronization therapy by tissue synchronization imaging [J].
Yu, CM ;
Zhang, Q ;
Fung, JWH ;
Chan, HCK ;
Chan, YS ;
Yip, GWK ;
Kong, SL ;
Lin, H ;
Zhang, Y ;
Sanderson, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (05) :677-684