Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro

被引:284
作者
Schileo, Enrico [1 ]
Taddei, Fulvia [1 ]
Cristofolini, Luca [1 ,2 ]
Viceconti, Marco [1 ]
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol, I-40136 Bologna, Italy
[2] Univ Bologna, Fac Engn, I-40126 Bologna, Italy
关键词
subject-specific finite element models; maximum principal strain; failure criteria; bone biomechanics; in vitro failure tests; experimental validation;
D O I
10.1016/j.jbiomech.2007.09.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
No agreement on the choice of the failure criterion to adopt for the bone tissue can be found in the literature among the finite element studies aiming at predicting fracture risk of bones. The use of stress-based criteria seems to prevail on strain-based ones, while basic bone biomechanics suggest using strain parameters to describe failure. The aim of the present combined experimental-numerical study was to verify, usinig subject-specific finite element models able to accurately predict strains, if a strain-based failure criterion could identify the failure patterns of bones. Three cadaver femurs were CT-scanned and subsequently fractured in a clinically relevant single-stance loading scenario. Load-displacement curves and high-speed movies were acquired to define the failure load and the location of fracture onset, respectively. Subject-specific finite element models of the three femurs were built from CT data following a validated procedure. A maximum principal strain criterion was implemented in the finite element models, and two stress-based criteria selected for comparison. The failure loads measured were applied to the models, and the computed risks of fracture were compared to the results of the experimental tests. The proposed principal strain criterion managed to correctly identify the level of failure risk and the location of fracture onset in all the modelled specimens, while Von Mises or maximum principal stress criteria did not give significant information. A maximum principal strain criterion can thus be defined a suitable candidate for the in vivo risk factor assessment on long bones. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:356 / 367
页数:12
相关论文
共 47 条
[1]  
*AJM, 1991, OST CONS DEV C 1991
[2]  
ALHO A, 1988, CLIN ORTHOP RELAT R, P292
[3]   The modified super-ellipsoid yield criterion for human trabecular bone [J].
Bayraktar, HH ;
Gupta, A ;
Kwon, RY ;
Papadopoulos, P ;
Keaveny, TM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (06) :677-684
[4]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[5]   Regional differences in cortical porosity in the fractured femoral neck [J].
Bell, KL ;
Loveridge, N ;
Power, J ;
Garrahan, N ;
Meggitt, BF ;
Reeve, J .
BONE, 1999, 24 (01) :57-64
[6]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[7]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[8]   Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric [J].
Chang, WCW ;
Christensen, TM ;
Pinilla, TP ;
Keaveny, TM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (04) :582-585
[9]   Short term in vivo precision of proximal femoral finite element modeling [J].
Cody, DD ;
Hou, FJ ;
Divine, GW ;
Fyhrie, DP .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :408-414
[10]   Femoral strength is better predicted by finite element models than QCT and DXA [J].
Cody, DD ;
Gross, GJ ;
Hou, FJ ;
Spencer, HJ ;
Goldstein, SA ;
Fyhrie, DP .
JOURNAL OF BIOMECHANICS, 1999, 32 (10) :1013-1020