Exergy transfer and parametric study of counter flow wet cooling towers

被引:29
|
作者
Wang, Li [1 ,2 ]
Li, Nianping [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Zhejiang Sci Tech Univ, Coll Civil Engn, Hangzhou 310018, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Exergy analysis; Exergy transfer; Cool exergy; Counter flow wet cooling tower; Thermal efficiency; PERFORMANCE; SIMULATION; EFFICIENCY; CFD;
D O I
10.1016/j.applthermaleng.2010.11.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermodynamic analysis of the counter flow wet cooling tower (CWCT) is performed in this paper. Both energy and exergy formulations are developed and validated for the system. Four types of exergy transfer processes occurring inside the CWCT are investigated schematically. A parametric study is conducted under various operating conditions in order to investigate the effects of thermal efficiency and water-to-air ratio on the exergy performance of the CWCT. Unlike past studies, the transiting exergy contained in the inlet and outlet water is not considered. It is found that the exergy efficiency is always less than 25%. The exergy parameters including evaporation water loss, exergy efficiency, exergy input, internal and external exergy losses are very sensitive to the thermal efficiency when it is very close to 1.0 at lower water-to-air ratios. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:954 / 960
页数:7
相关论文
共 50 条
  • [1] Energy and exergy analysis of counter flow wet cooling towers
    Saravanan, M.
    Saravanan, R.
    Renganarayanan, S.
    THERMAL SCIENCE, 2008, 12 (02): : 69 - 78
  • [2] A modified analysis of counter flow wet cooling towers
    El-Dessouky, H.T.A.
    Al-Haddad, A.
    Al-Juwayhel, F.
    Journal of Heat Transfer, 1997, 119 (03): : 617 - 626
  • [3] A modified analysis of counter flow wet cooling towers
    ElDessouky, HTA
    AlHaddad, A
    AlJuwayhel, F
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1997, 119 (03): : 617 - 626
  • [4] Performance characteristics of counter flow wet cooling towers
    Khan, JUR
    Yaqub, M
    Zubair, SM
    ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (13) : 2073 - 2091
  • [5] A comprehensive design and performance evaluation study of counter flow wet cooling towers
    Khan, JUR
    Qureshi, BA
    Zubair, SM
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08): : 914 - 923
  • [6] A study of fouling and its effects on the performance of counter flow wet cooling towers
    Khan, JUR
    Zubair, SM
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2004, 218 (E1) : 43 - 51
  • [7] An improved design and rating analyses of counter flow wet cooling towers
    Khan, JUR
    Zubair, SM
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2001, 123 (04): : 770 - 778
  • [8] Numerical simulation of counter-flow wet-cooling towers
    Heidarinejad, Ghassem
    Karami, Maryam
    Delfani, Shahram
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 996 - 1002
  • [9] MINLP optimization of mechanical draft counter flow wet-cooling towers
    Serna-Gonzalez, Medardo
    Ponce-Ortega, Jose M.
    Jimenez-Gutierrez, Arturo
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2010, 88 (5-6A): : 614 - 625
  • [10] Parametric study of induced draft counter flow rectangular cooling tower based on exergy analysis
    Aggarwal, Gaurav
    Kachhwaha, S. S.
    Mishra, R. S.
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2010, 69 (04): : 284 - 292