Diagnostic values of positron emission tomography versus triple-phase bone scan in hip arthroplasty loosening

被引:71
作者
Mumme, T
Reinartz, P
Alfer, J
Müller-Rath, R
Buell, U
Wirtz, DC
机构
[1] Univ Hosp, Dept Orthopaed Surg, D-52074 Aachen, Germany
[2] Univ Hosp, Dept Nucl Med, Aachen, Germany
[3] Univ Hosp, Inst Pathol, Aachen, Germany
关键词
positron emission tomography; triple-phase bone scan; loosening; total hip arthroplasty; wear debris;
D O I
10.1007/s00402-005-0810-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The most frequent complications of total hip arthroplasty are septic and aseptic wear-induced loosening. A reliable differentiation between septic and aseptic loosening with current diagnostic tools is not possible. Therefore, we examined the diagnostic valency of positron emission tomography (PET) with F-18- fluorodeoxyglucose (FDG) in cases of septic or aseptic hip arthroplasty loosening compared with conventional triple-phase bone scan (TPBS). Materials and methods Fifty patients with 70 total hip replacements (symptomatic n=50, asymptomatic n=20) were examined by means of FDG-PET and TPBS to detect septic and aseptic loosening and differentiate between the two. A differentiated algorithm subdivided into categories I-V was developed for FDG-PET. Additionally, standardized uptake values (SUV) were calculated from the lesion with the highest FDG uptake. Interpretations of the TPBS were done according to the criteria described by Wilson. The final diagnosis was based on operative findings including microbiological and histological examinations (n=50), while the remaining asymptomatic arthroplasties (n=20) were integrated into a clinical follow-up (>= 9 months). Results Sensitivity/specificity of FDG-PET was 91%/92% (accuracy 91%) compared with 78%/70% (accuracy 74%) for TPBS. A high correlation could be proved between FDG-PET investigation and operative histopathological findings (r(Spear)>= 0.9). No significant differences were found regarding cemented and uncemented implanted hip arthroplasties (p >= 0.05). Calculation of the SUV turned out to be inappropriate as a sole criterion for image interpretation. Conclusion FDG-PET is a promising, highly accurate examination method to detect polyethylene and metal wear-induced chronic inflammation followed by periprosthetic osteolysis. In addition, FDG-PET has a significantly higher sensitivity and specificity than TPBS for differentiating between aseptic loosening and infection.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 34 条
[1]  
Bax Jeroen J., 2000, Seminars in Nuclear Medicine, V30, P281, DOI 10.1053/snuc.2000.9543
[2]   The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prostheses [J].
Chacko, TK ;
Zhuang, H ;
Stevenson, K ;
Moussavian, B ;
Alavi, A .
NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (09) :851-855
[3]  
Coleman R Edward, 1998, Clin Positron Imaging, V1, P15, DOI 10.1016/S1095-0397(97)00004-6
[4]   Coincidence camera FDG imaging for the diagnosis of chronic orthopedic infections: A feasibility study [J].
de Winter, F ;
Van de Wiele, C ;
Vandenberghe, S ;
de Bondt, P ;
de Clercq, D ;
D'Asseler, Y ;
Dierckx, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (02) :184-189
[5]  
DEWINTER F, 2000, J NUCL MED S, V15
[6]  
ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
[7]   OSTEOMYELITIS - CHARACTERISTICS AND PITFALLS OF DIAGNOSIS WITH MR IMAGING [J].
ERDMAN, WA ;
TAMBURRO, F ;
JAYSON, HT ;
WEATHERALL, PT ;
FERRY, KB ;
PESHOCK, RM .
RADIOLOGY, 1991, 180 (02) :533-539
[8]  
FRIEDEBOLD G, 1987, MED WELT, V38, P1386
[9]  
Garellick G, 2000, CLIN ORTHOP RELAT R, P157
[10]  
Guhlmann A, 1998, J NUCL MED, V39, P2145