Comprehensive Echocardiographic Assessment of Mechanical Tricuspid Valve Prostheses Based on Early Post-Implantation Echocardiographic Studies

被引:11
作者
Blauwet, Lori A. [1 ]
Burkhart, Harold M. [2 ]
Dearani, Joseph A. [2 ]
Malouf, Joseph F. [1 ]
Connolly, Heidi M. [1 ]
Hodge, David O. [3 ]
Herges, Regina M. [3 ]
Miller, Fletcher A., Jr. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Div Cardiovasc Surg, Rochester, MN 55905 USA
[3] Mayo Clin, Div Biomed Informat & Biostat, Rochester, MN 55905 USA
关键词
Doppler; Echocardiography; Heart valve prosthesis; Tricuspid valve; VELOCITY INTEGRAL RATIO; DOPPLER-ECHOCARDIOGRAPHY; PERFORMANCE INDEX; MITRAL PROSTHESES; HANCOCK-II; TIME; BIOPROSTHESES; REPLACEMENT; POSITION; RECOMMENDATIONS;
D O I
10.1016/j.echo.2010.12.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Doppler-derived hemodynamic data for normal tricuspid mechanical valve prostheses are limited. Methods: A comprehensive retrospective Doppler echocardiographic assessment of 78 normal St. Jude Medical Standard (St. Jude Medical, Inc., St. Paul, MN), CarboMedics Standard (CarboMedics, Inc., Sorin Group, Burnaby, British Columbia, Canada), and Starr-Edwards (Edwards Lifesciences, LLC, Irvine, CA) mechanical tricuspid valve prostheses was performed early after implantation. We used all the important Doppler-derived hemodynamic variables reported to date, including peak early diastolic velocity (E velocity), mean gradient, pressure half-time, time velocity integral of the tricuspid valve prosthesis (TVITVP), and ratio of the time velocity integral of the tricuspid valve prosthesis to the time velocity integral of the left ventricular outflow tract (TVITVP/TVILVOT). Results: The mean values obtained for the Doppler parameters did not differ significantly when the measurements from five or nine consecutive cardiac cycles were averaged. Pressure half-time was <130 msec in all 43 patients with St. Jude Medical Standard and CardioMedics Standard prostheses in whom it could be measured. Mean gradient <6 mm Hg, E velocity <1.9 m/s, TVITVP <46 cm, and TVITVP/TVILVOT <2.1 were recorded in 59 (87%) of the 68 patients with either of these prostheses. Hemodynamic variables were considerably less favorable in patients with Starr-Edwards prostheses. Conclusion: These calculated threshold values (mean + 2SD) are useful for identifying normal tricuspid mechanical valve function. Prostheses with values for hemodynamic variables that are outside the mean + 2 SD parameters that we have calculated are most likely to be dysfunctional. However, in rare cases, mechanical tricuspid valve prostheses may be dysfunctional even when their hemodynamic parameters are within these specified ranges because of small body surface area or other factors. (J Am Soc Echocardiogr 2011;24:414-24.)
引用
收藏
页码:414 / 424
页数:11
相关论文
共 25 条
[1]  
Aoyagi S, 1993, J Heart Valve Dis, V2, P279
[2]  
Aoyagi Shigeaki, 2003, Asian Cardiovasc Thorac Ann, V11, P193
[3]   Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) :1-23
[4]   Doppler echocardiography of 79 normal CarboMedics mitral prostheses: A comprehensive assessment including time-velocity integral ratio and prosthesis performance index [J].
Blauwet, Lori A. ;
Malouf, Joseph F. ;
Connolly, Heidi M. ;
Hodge, David O. ;
Herges, Regina M. ;
Sundt, Thoralf M., III ;
Miller, Fletcher A., Jr. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (10) :1125-1130
[5]   Comprehensive Echocardiographic Assessment of the Hemodynamic Parameters of 285 Tricuspid Valve Bioprostheses Early after Implantation [J].
Blauwet, Lori A. ;
Danielson, Gordon K. ;
Burkhart, Harold M. ;
Dearani, Joseph A. ;
Malouf, Joseph F. ;
Connolly, Heidi M. ;
Hodge, David O. ;
Herges, Regina M. ;
Miller, Fletcher A., Jr. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (10) :1045-U72
[6]   Comprehensive Echocardiographic Assessment of Normal Mitral Medtronic Hancock II, Medtronic Mosaic, and Carpentier-Edwards Perimount Bioprostheses Early after Implantation [J].
Blauwet, Lori A. ;
Malouf, Joseph F. ;
Connolly, Heidi M. ;
Hodge, David O. ;
Evans, Katie N. ;
Herges, Regina M. ;
Sundt, Thoralf M., III ;
Miller, Fletcher A., Jr. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (06) :656-666
[7]   Doppler Echocardiography of 240 Normal Carpentier-Edwards Duraflex Porcine Mitral Bioprostheses: A Comprehensive Assessment Including Time Velocity Integral Ratio and Prosthesis Performance Index [J].
Blauwet, Lori A. ;
Malouf, Joseph F. ;
Connolly, Heidi M. ;
Hodge, David O. ;
Evans, Katie N. ;
Herges, Regina M. ;
Sundt, Thoralf M., III ;
Miller, Fletcher A., Jr. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (04) :388-393
[8]   Tricuspid valve repair for Ebstein's anomaly in young children: A 30-year experience [J].
Boston, US ;
Dearani, JA ;
O'Leary, PW ;
Driscoll, DJ ;
Danielson, GK .
ANNALS OF THORACIC SURGERY, 2006, 81 (02) :690-696
[9]   DOPPLER HEMODYNAMIC PROFILES OF 82 CLINICALLY AND ECHOCARDIOGRAPHICALLY NORMAL TRICUSPID-VALVE PROSTHESES [J].
CONNOLLY, HM ;
MILLER, FA ;
TAYLOR, CL ;
NAESSENS, JM ;
SEWARD, JB ;
TAJIK, AJ .
CIRCULATION, 1993, 88 (06) :2722-2727
[10]   CLINICAL AND HEMODYNAMIC ASSESSMENT OF THE HANCOCK-II BIOPROSTHESIS [J].
DAVID, TE ;
ARMSTRONG, S ;
SUN, Z .
ANNALS OF THORACIC SURGERY, 1992, 54 (04) :661-668