Monte Carlo simulation of an optical coherence Doppler tomograph signal: the effect of the concentration of particles in a flow on the reconstructed velocity profile

被引:9
作者
Bykov, AV
Kirillin, MY
Priezzhev, AV
机构
[1] Moscow MV Lomonosov State Univ, Dept Phys, Moscow 119992, Russia
[2] Moscow MV Lomonosov State Univ, Int Teaching & Res Laser Ctr, Moscow 119992, Russia
关键词
Monte Carlo method; light scattering; optical coherence Doppler tomography; coherence length; velocity profile; intralipid;
D O I
10.1070/QE2005v035n02ABEH003337
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Model signals of an optical coherence Doppler tomograph (OCDT) are obtained by the Monte Carlo method from a flow of a light-scattering suspension of lipid vesicles (intralipid) at concentrations from 0.7 % to 1.5 % with an a priori specified parabolic velocity profile. The velocity profile parameters reconstructed from the OCDT signal and scattering orders of the photons contributing to the signal are studied as functions of the suspension concentration. It is shown that the maximum of the reconstructed velocity profile at high concentrations shifts with respect to the symmetry axis of the flow and its value decreases due to a greater contribution from multiply scattered photons.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 15 条
[1]   Optical Doppler tomography [J].
Chen, ZP ;
Zhao, YH ;
Srinivas, SM ;
Nelson, JS ;
Prakash, N ;
Frostig, RD .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :1134-1142
[2]   OPTICAL-PROPERTIES OF INTRALIPID - A PHANTOM MEDIUM FOR LIGHT-PROPAGATION STUDIES [J].
FLOCK, ST ;
JACQUES, SL ;
WILSON, BC ;
STAR, WM ;
VANGEMERT, MJC .
LASERS IN SURGERY AND MEDICINE, 1992, 12 (05) :510-519
[3]   Flow velocity profile measurement of scattering liquid using Doppler Optical Coherence Tomography [J].
Hast, J ;
Prykäri, T ;
Alarousu, E ;
Myllylä, R ;
Priezzhev, A .
OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 :66-72
[4]  
Kandidov VP, 1996, USP FIZ NAUK+, V166, P1309, DOI 10.1070/PU1996v039n12ABEH000185
[5]   Monte Carlo simulation of laser beam propagation in a plane layer of the erythrocyte suspension: comparison of contributions from different scattering orders to the angular distribution of light intensity [J].
Kirillin, MY ;
Priezzhev, A .
QUANTUM ELECTRONICS, 2002, 32 (10) :883-887
[6]   On refraction in Monte-Carlo simulations of light transport through biological tissues [J].
Kolinko, VG ;
deMul, FFM ;
Greve, J ;
Priezzhev, AV .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (03) :287-288
[7]   Accuracy and noise in optical Doppler tomography studied by Monte Carlo simulation [J].
Lindmo, T ;
Smithies, DJ ;
Chen, ZP ;
Nelson, JS ;
Milner, TE .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :3045-3064
[8]  
Lopatin V.V., 2000, BIOMED RADIOELEKTRON, V7, P29
[9]  
Milner TE, 2002, HANDBOOK OF OPTICAL COHERENCE TOMOGRAPHY, P203
[10]   Computer simulation of light scattering from dynamic inhomogeneities in live tissue [J].
Priezzhev, AV ;
Fedoseev, VV ;
Kudinov, DV .
SARATOV FALL MEETING '98: LIGHT SCATTERING TECHNOLOGIES FOR MECHANICS, BIOMEDICINE, AND MATERIAL SCIENCE, 1999, 3726 :567-575