Effects of Auxiliary Electrode Width in AC Plasma Display Panels With Auxiliary Electrodes

被引:1
|
作者
Lee, Sung-Min [1 ]
Choi, Chung Sock [1 ]
Choi, Kyung Cheol [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
来源
JOURNAL OF DISPLAY TECHNOLOGY | 2010年 / 6卷 / 12期
关键词
Auxiliary electrode; discharge mode; electrode width; plasma-display panel (PDP); HIGH LUMINOUS EFFICACY; HIGH-XE-CONTENT; PDP; MICROPLASMA; DISCHARGES; CELL; DIAGNOSTICS; VOLTAGE; GAP;
D O I
10.1109/JDT.2010.2064757
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We investigated the effects of changing the width of the auxiliary electrode in an ac plasma display panel including centrally located auxiliary electrodes between the sustain electrodes, based on analyses of the discharge mode. A panel with auxiliary electrodes was driven by pulse waveforms that included auxiliary pulses applied to the auxiliary electrode immediately after every sustain pulse. The discharge modes are changed consecutively from mode 1 to mode 3-2 when the sustain or auxiliary pulse voltages are increased, which can be characterized as follows [16]: 1) only the sustain pulse discharges are generated in mode 1; 2) one of a pair of the auxiliary pulse discharges is additionally generated in mode 2; and 3) the other auxiliary pulse discharge is also generated in mode 3-1 and mode 3-2. Distribution of the discharge mode changes in accordance with the width of the auxiliary electrode (the focus is on modes 1 and 2 because these modes are effective modes); as the auxiliary electrode is narrowed, the range of mode 1 becomes wide and the range of mode 2 becomes narrow. The wide range of mode 1 is attributed to the fact that the discharge of the auxiliary pulse is suppressed due to a longer gap between the sustain and auxiliary electrodes. The narrow range of mode 2 is caused by the discharge of the auxiliary pulse less affecting the discharge of the sustain pulse. Since the auxiliary electrode provides less of a decrease in the number of wall charges on the sustain electrodes, the voltage margin is improved for the case of the narrow auxiliary electrode. The luminous efficacy is mostly improved in mode 1 for the case of the narrow auxiliary electrode due to the auxiliary pulse with a higher voltage generating a larger number of space charges, as well as in mode 2 for the case of the wide auxiliary electrode due to a short electrode gap rendering a great number of wall charges decreasing.
引用
收藏
页码:607 / 613
页数:7
相关论文
共 26 条
  • [21] Nanoplasmon-Enhanced Light Emitter for AC Plasma Display Panels With Large Scalability
    Lee, Seong Min
    Kim, Young Kwan
    Kim, Min Kyu
    Park, Hyoung-Bin
    Choi, Kyung Cheol
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2012, 59 (10) : 2727 - 2734
  • [22] A Novel Single-Stage AC-DC Converter to Supply Sustain Power for Plasma Display Panels
    Choi, Woo-Young
    Choi, Jae-Yeon
    JOURNAL OF DISPLAY TECHNOLOGY, 2011, 7 (09): : 494 - 502
  • [23] Effects of Gas Pressure on Temporal Image Sticking in AC Plasma Display Panel
    Kim, Jae Hyun
    Park, Choon-Sang
    Tae, Heung-Sik
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2012, 564 : 67 - 75
  • [24] Effects of Address-on-Time on Wall Voltage Variation during Address-Period in AC Plasma Display Panel
    Choi, Byung-Tae
    Park, Hyung Dal
    Tae, Heung-Sik
    IEICE TRANSACTIONS ON ELECTRONICS, 2009, E92C (11) : 1347 - 1352
  • [25] The effects of hump electrode on the long gap plasma display panel with high Xe concentration ratio
    Ok, Jung-Woo
    Song, In-Cheol
    Lee, Don-Kyu
    Kim, Dong-Hyun
    Lee, Hae June
    Lee, Ho-Jun
    Park, Chung-Hoo
    THIN SOLID FILMS, 2010, 518 (22) : 6174 - 6178
  • [26] Analysis on electron emission characteristics of MgO layer with MgO crystal powder under various panel temperatures in ac-plasma display panels
    Kim, Jae Hyun
    Park, Hyung Dal
    Park, Choon-Sang
    Kim, Hyun-Jin
    Shin, Bhum Jae
    Seo, Jeong Hyun
    Tae, Heung-Sik
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2017, 645 (01) : 102 - 111