摘要
We present the method measuring the thickness and the refractive index of a transparent specimen at a same time based on full-field optical coherence tomography. As a sample a small drop of epoxy was placed on a flat plate and the high-resolution depth resolved en-face images of the epoxy drop were taken. With adopting the plate surface as a reference plane, the physical thickness and the refractive index distribution could be obtained. Owing to the full-field imaging capability, we could obtain the transverse distributions of the thickness and the refractive index without any transverse scanning. The measured thickness at the center of the sample was 24 mu m and the average index was 1.4055 with the standard deviation of 0.0002.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Thickness and Refractive Index Measurements by Full-Field Optical Coherence Microscopy
    Na, Jihoon
    Choi, Woo June
    Choi, Hae Young
    Ryu, Seon Young
    Choi, Eun Seo
    Lee, Byeong Ha
    IEEE SENSORS JOURNAL, 2009, 9 (12) : 1996 - 1997
  • [2] Full-field optical coherence microscopy
    Cent Natl de la Recherche, Paris, France
    Opt Lett, 4 (244-246):
  • [3] Full-field optical coherence microscopy
    Beaurepaire, E
    Boccara, AC
    Lebec, M
    Blanchot, L
    Saint-Jalmes, H
    OPTICS LETTERS, 1998, 23 (04) : 244 - 246
  • [4] Full-field optical coherence microscopy
    Dubois, A
    Grieve, K
    Moneron, G
    Boccara, AC
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 107 - 111
  • [5] Extended Full-field Optical Coherence Microscopy
    Dubois, Arnaud
    3RD INTERNATIONAL TOPICAL MEETING ON OPTICAL SENSING AND ARTIFICIAL VISION (OSAV'2012), 2013, 1537 : 123 - 132
  • [6] Retinal imaging with full-field optical coherence microscopy
    Grieve, Kate
    Borderie, Vincent
    Paques, Michel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [7] Bichromatic tetraphasic full-field optical coherence microscopy
    Iyer, Rishyashring R.
    Zurauskas, Mantas
    Rao, Yug
    Chaney, Eric J.
    Boppart, Stephen A.
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29
  • [8] Combined full-field fluorescence and optical coherence microscopy
    Perronet, K.
    Makhlouf, H.
    Dubois, A.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2013, 42 : S104 - S104
  • [9] Full-field Optical Coherence Tomography Apply in Sphere Measurements
    Shi Wei
    Li Weiwei
    Li Juncheng
    Wang Jingyu
    Wang Jianguo
    ADVANCED OPTICAL DESIGN AND MANUFACTURING TECHNOLOGY AND ASTRONOMICAL TELESCOPES AND INSTRUMENTATION, 2016, 10154
  • [10] Full-field optical coherence microscopy with optimized ultrahigh spatial resolution
    Federici, Antoine
    Dubois, Arnaud
    OPTICS LETTERS, 2015, 40 (22) : 5347 - 5350