Rhythmia zero-fluoroscopy workflow with high-power, short-duration ablation: retrospective analysis of procedural data

被引:4
|
作者
Cuellar-Silva, Jose R. [1 ]
Albrecht, Elizabeth M. [2 ]
Sutton, Brad S. [2 ]
机构
[1] Cardiac Rhythm Ctr Houston, 250 Blossom St Suite 275, Webster, TX 77598 USA
[2] Boston Sci Corp, St Paul, MN USA
关键词
Atrial fibrillation; Catheter ablation; Zero fluoroscopy; High-density mapping; CATHETER ABLATION; CARDIAC-ARRHYTHMIAS; ATRIAL-FIBRILLATION; SAFETY;
D O I
10.1007/s10840-022-01283-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Fluoroscopy is commonly used during atrial fibrillation (AF) ablation to guide catheter navigation and placement. Technology improvements have significantly reduced fluoroscopy time, and subsequent radiation dose, necessary to perform successful ablations. However, there is still no amount of radiation exposure known to be completely safe. The aim of this manuscript is to describe a detailed zero-fluoroscopy RHYTHMIA HDx workflow for AF ablation. Methods: This was an observational, single-center experience to describe the technique, acute procedural success, and safety using a novel zero-fluoroscopy workflow with the RHYTHMIA HDx mapping system and intracardiac echocardiography (ICE). Seventy-two consecutive patients undergoing de novo or redo AF ablation were retrospectively analyzed. Venous access was guided with ultrasound. ICE combined with the mapping system's magnetic tracking and sheath detection was used for precise catheter placement in the coronary sinus, at the transseptal puncture, and in the left atrium. A high-power, short-duration ablation strategy guided by local impedance was used. Pulmonary vein isolation was performed or touched up for all patients with additional lines added at the operator's discretion. Results: Using this zero-fluoroscopy workflow, all patients achieved acute isolation with no significant procedure-related complications. Average procedure time was 73.7 +/- 16.2 min, which included persistent (58%) and paroxysmal (42%) AF cases, and no procedures required conversion to fluoroscopy. Conclusions: In this experience, a zero-fluoroscopy workflow using the RHYTHMIA HDx mapping system combined with ICE was feasible and safe for ablation in a heterogenous AF population. This approach, in the appropriate patient population, can eliminate radiation exposure to patients and staff.
引用
收藏
页码:499 / 507
页数:9
相关论文
共 50 条
  • [41] One-year outcomes in patients undergoing very high-power short-duration ablation for atrial fibrillation
    Solimene, Francesco
    Strisciuglio, Teresa
    Schillaci, Vincenzo
    Arestia, Alberto
    Shopova, Gergana
    Salito, Armando
    Bottaro, Giuseppe
    Marano, Giovanni
    Coltorti, Fernando
    Stabile, Giuseppe
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (08) : 1911 - 1917
  • [42] The evolution of high-power short-duration atrial fibrillation ablation: "The long slog"
    Winkle, Roger A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 342 - 344
  • [43] Impact of High-Power Short-Duration Radiofrequency Ablation on Esophageal Temperature Dynamic
    Yavin, Hagai D.
    Bubar, Zachary P.
    Higuchi, Koji
    Sroubek, Jakub
    Kanj, Mohamed
    Cantillon, Daniel
    Saliba, Walid, I
    Tarakji, Khaldoun G.
    Hussein, Ayman A.
    Wazni, Oussama
    Anter, Elad
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (11) : 1014 - 1023
  • [44] Comparison of traditional radiofrequency ablation and high-power short-duration ablation in the treatment of atrial tachyarrhythmias
    Yakushev, A., V
    Paratsii, O. Z.
    ZAPOROZHYE MEDICAL JOURNAL, 2022, 24 (04) : 385 - 389
  • [45] HPSD ablation for AF high-power short-duration RF ablation for atrial fibrillation: A review
    Winkle, Roger A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (10) : 2813 - 2823
  • [46] High-power short-duration ablation index–guided pulmonary vein isolation protocol using a single catheter
    Patrick Badertscher
    Sven Knecht
    Florian Spies
    Gian Völlmin
    Beat Schaer
    Nicolas Schärli
    Flurina Bosshard
    Stefan Osswald
    Christian Sticherling
    Michael Kühne
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 633 - 642
  • [47] Optimal conditions for high-power, short-duration radiofrequency ablation using a novel, flexible- tipped, force-sensing catheter
    Piccini, Jonathan P.
    Dave, Amish S.
    Holmes, Douglas S.
    Winter, Jeffrey R.
    Tranter, John H.
    Pipenhagen, Catherine
    Moon, L. Boyce
    Ambrosius, Nicholas M.
    Overmann, Jed A.
    Boudlali, Hana
    Thao, Riki
    Geurkink, Chris
    Thamavong, Zada
    Jensen, James A.
    Fish, Jeffrey M.
    HEART RHYTHM O2, 2023, 4 (07): : 440 - 447
  • [48] Efficacy and safety of high-power short-duration ablation for atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials
    Amin, Ahmed Mazen
    Ghaly, Ramy
    Ibrahim, Ahmed A.
    Ali, Mohamed Ahmed
    Almaadawy, Omar
    Elzahaby, Amr
    Abuelazm, Mohamed
    Abdelazeem, Basel
    Munir, Muhammad Bilal
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (06) : 1445 - 1461
  • [49] High-power short-duration ablation of atrial fibrillation: A contemporary review
    Naniwadekar, Aditi
    Dukkipati, Srinivas R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (03): : 528 - 540
  • [50] Proactive esophageal cooling protects against thermal insults during high-power short-duration radiofrequency cardiac ablation
    Mercado-Montoya, Marcela
    Gomez-Bustamante, Tatiana
    Berjano, Enrique
    Mickelsen, Steven
    Daniels, James
    Hernandez-Arango, Pablo
    Schieber, Jay
    Kulstad, Erik
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 1202 - 1212