Heart rate variability measures: a fresh look at reliability

被引:192
|
作者
Pinna, Gian Domenico [1 ]
Maestri, Roberto
Torunski, Antoni
Danilowicz-Szymanowicz, Ludmilla
Szwoch, Mallgorzata
La Rovere, Maria Teresa
Raczak, Grzegorz
机构
[1] S Maugeri Fdn IRCCS, Sci Inst Montescano, Dept Cardiol & Biomed Engn, Montescano, PV, Italy
[2] Med Univ, Dept Cardiol, Gdansk, Poland
关键词
ECG; heart rate variability; high-frequency power; low-frequency power; paced breathing; RR interval;
D O I
10.1042/CS20070055
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Despite its extensive use in physiological and clinical research, the analysis of HRV (heart rate variability) is still poorly supported by rigorous reliability studies. The main aim of the present study was to perform an in-depth assessment of absolute and relative reliability of standard indexes of HRV from short-term laboratory recordings. In 39 healthy subjects [mean age (min-max): 38 (2656) years; 18 men and 21 women] we recorded 5 min of supine ECG during spontaneous and paced (15 breaths/min) breathing. The test was repeated on the next day under the same conditions. From the RR intervals we computed standard indexes of HRV: SDNN (S.D. of RR interval values), RMSSD (root-mean-square of successive RR interval differences), LF (low frequency) and HF (high frequency) power (absolute and normalized units) and LF/HF. Absolute reliability was assessed by 95 % limits of random variation; relative reliability was assessed by the ICC (intraclass correlation coefficient). The sample size needed to detect a mean difference >= 30% of the between-subject S.D. was also estimated. Although there was no significant mean change between the two tests, we found that in individual subjects the second measurement was as high/low as 1.9/0.5 times (SDNN, best case) and 3.5/0.3 times (LF/HF, worst case) the first measurement, due to pure random variation. For most parameters the ICC was > 0.8 (range 0.65-0.88). The estimated sample size ranged from 24-98 subjects. Reliability indexes tended to improve during paced breathing. We conclude that short-term HRV parameters are subject to large day-to-day random variations. Random error, however, represents a limited part of the between-subject variability; therefore observed differences between individuals mostly reflect differences in the subjects' error-free value rather than random error. Overall, paced breathing improves reliability.
引用
收藏
页码:131 / 140
页数:10
相关论文
共 50 条
  • [41] Electrocardiographic measures and heart rate variability in patients with familial dysautonomia
    Axelrod, FB
    Putman, D
    Berlin, D
    Rutkowski, M
    CARDIOLOGY, 1997, 88 (02) : 133 - 140
  • [42] Autonomic function evaluated by entropy measures of the heart rate variability
    Clariá, F
    Vallverdú, M
    Martinez, P
    Alonso, JL
    Viñolas, X
    Zareba, W
    de Luna, AB
    Caminal, P
    COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 : 461 - 464
  • [43] EFFECT OF IMIPRAMINE TREATMENT ON HEART-RATE-VARIABILITY MEASURES
    YERAGANI, VK
    POHL, R
    BALON, R
    RAMESH, C
    GLITZ, D
    WEINBERG, P
    MERLOS, B
    NEUROPSYCHOBIOLOGY, 1992, 26 (1-2) : 27 - 32
  • [44] Comparison of Heart Rate Variability Measures for Mental Stress Detection
    Boonnithi, Sansanee
    Phongsuphap, Sukanya
    2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 85 - 88
  • [45] The reliability of short-term measurements of heart rate variability
    Sandercock, GRH
    Bromley, PD
    Brodie, DA
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 103 (03) : 238 - 247
  • [46] RELIABILITY AND VARIABILITY OF INDICATORS OF HEART-RATE MONITORING IN CHILDREN
    DURANT, RH
    BARANOWSKI, T
    DAVIS, H
    RHODES, T
    THOMPSON, WO
    GREAVES, KA
    PUHL, J
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (03): : 389 - 395
  • [47] RELIABILITY OF HEART RATE VARIABILITY DURING DYNAMIC HANDGRIP EXERCISE
    Kluess, H. A.
    Wood, R. H.
    Stone, D. J.
    Weslch, M. A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S203 - S203
  • [48] Reliability of the heart rate variability threshold during treadmill exercise
    Hargens, Trent A.
    Chambers, Shane
    Luden, Nicholas D.
    Womack, Christopher J.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2022, 42 (04) : 292 - 299
  • [49] Test-retest Reliability of Female Heart Rate Variability
    Murley, Meghan
    Marks, Charles R. C.
    Drouin, Jacqueline S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 725 - 725
  • [50] RELIABILITY AND COMPARISON OF METHODS TO CALCULATE HEART-RATE-VARIABILITY
    GELBER, D
    PFEIFER, M
    SCHUMER, M
    DIABETES, 1995, 44 : A66 - A66