Quantitative Ultrashort Echo Time (UTE) MRI of Human Cortical Bone: Correlation With Porosity and Biomechanical Properties

被引:137
作者
Bae, Won C. [1 ]
Chen, Peter C. [2 ]
Chung, Christine B. [1 ]
Masuda, Koichi [3 ]
D'Lima, Darryl [2 ]
Du, Jiang [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Scripps Clin, Shiley Ctr Orthoped Res & Educ, La Jolla, CA 92037 USA
[3] Univ Calif San Diego, Dept Orthopaed Surg, La Jolla, CA 92093 USA
基金
美国国家卫生研究院;
关键词
ULTRASHORT TE; BICOMPONENT ANALYSIS; FREE WATER; BOUND WATER; POROSITY; BIOMECHANICAL PROPERTIES; NUCLEAR-MAGNETIC-RESONANCE; PROTON PROJECTION MRI; AGE-RELATED-CHANGES; MECHANICAL-PROPERTIES; MINERAL DENSITY; COMPACT-BONE; HIP FRACTURE; OSTEOPOROTIC FRACTURES; DISTAL RADIUS; WATER;
D O I
10.1002/jbmr.1535
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study we describe the use of ultrashort echo time (UTE) magnetic resonance imaging (MRI) to evaluate short and long T2* components as well as the water content of cortical bone. Fourteen human cadaveric distal femur and proximal tibia were sectioned to produce 44 rectangular slabs of cortical bone for quantitative UTE MR imaging, microcomputed tomography (mu CT), and biomechanical testing. A two-dimensional (2D) UTE pulse sequence with a minimal nominal TE of 8 mu seconds was used together with bicomponent analysis to quantify the bound and free water in cortical bone using a clinical 3T scanner. Total water concentration was measured using a 3D UTE sequence together with a reference water phantom. UTE MR measures of water content (total, free, and bound), T2* (short and long), and short and long T2* fractions were compared with porosity assessed with mu CT, as well as elastic (modulus, yield stress, and strain) and failure (ultimate stress, failure strain, and energy) properties, using Pearson correlation. Porosity significantly correlated positively with total (R-2 = 0.23; p < 0.01) and free (R-2 = 0.31; p < 0.001) water content as well as long T2* fraction (R-2= 0.25; p < 0.001), and negatively with short T2* fraction and short T2* (R-2 = 0.24; p < 0.01). Failure strain significantly correlated positively with short T2* (R-2 = 0.29; p < 0.001), ultimate stress significantly correlated negatively with total (R-2 = 0.25; p < 0.001) and bound (R-2 = 0.22; p < 0.01) water content, and failure energy significantly correlated positively with both short (R-2 = 0 30; p < 0.001) and long (R-2 =0.17; p < 0.01) T2* values. These results suggest that UTE MR measures are sensitive to the structure and failure properties of human cortical bone, and may provide a novel way of evaluating cortical bone quality. (c) 2012 American Society for Bone and Mineral Research.
引用
收藏
页码:848 / 857
页数:10
相关论文
共 65 条
[1]  
*AM SOC BON MIN RE, 2004, ASBMR BON CURR
[2]   Optimisation of T2 and M0 measurements of bi-exponential systems [J].
Anastasiou, A ;
Hall, LD .
MAGNETIC RESONANCE IMAGING, 2004, 22 (01) :67-80
[3]  
[Anonymous], 1994, WHO TECHN REP SER, V843
[4]   Collagen and bone strength [J].
Boskey, AL ;
Wright, TM ;
Blank, RD .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (03) :330-335
[5]  
BRANDI ML, 2009, RHEUMATOLOGY OXFO S4, V48, P3
[6]   Age- and Gender-Related Differences in the Geometric Properties and Biomechanical Significance of Intracortical Porosity in the Distal Radius and Tibia [J].
Burghardt, Andrew J. ;
Kazakia, Galateia J. ;
Ramachandran, Sweta ;
Link, Thomas M. ;
Majumdar, Sharmila .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (05) :983-993
[7]   CONTRIBUTION OF COLLAGEN AND MINERAL TO ELASTIC-PLASTIC PROPERTIES OF BONE [J].
BURSTEIN, AH ;
ZIKA, JM ;
HEIPLE, KG ;
KLEIN, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (07) :956-961
[8]   Quantitative 31P NMR spectroscopy and 1H MRI measurements of bone mineral and matrix density differentiate metabolic bone diseases in rat models [J].
Cao, Haihui ;
Nazarian, Ara ;
Ackerman, Jerome L. ;
Snyder, Brian D. ;
Rosenberg, Andrew E. ;
Nazarian, Rosalynn M. ;
Hrovat, Mirko I. ;
Dai, Guangping ;
Mintzopoulos, Dionyssios ;
Wu, Yaotang .
BONE, 2010, 46 (06) :1582-1590
[9]   Quantitative Bone Matrix Density Measurement by Water- and Fat-Suppressed Proton Projection MRI (WASPI) With Polymer Calibration Phantoms [J].
Cao, Haihui ;
Ackerman, Jerome L. ;
Hrovat, Mirko I. ;
Graham, Lila ;
Glimcher, Melvin J. ;
Wu, Yaotang .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1433-1443
[10]   Bone poroelasticity [J].
Cowin, SC .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :217-238