68Ga-PSMA-11 dose reduction for dedicated pelvic imaging with simultaneous PET/MR using TOF BSREM reconstructions

被引:12
作者
Svirydenka, Hanna [1 ,2 ]
Muehlematter, Urs J. [1 ,3 ]
Nagel, Hannes W. [1 ,4 ]
Delso, Gaspar [5 ]
Ferraro, Daniela A. [1 ]
Kudura, Ken [1 ]
Burger, Irene A. [1 ,6 ]
ter Voert, Edwin E. G. W. [1 ,7 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Ramistr 100, CH-8091 Zurich, Switzerland
[2] Med Univ Innsbruck, Dept Nucl Med, Anichstr 35, A-6020 Innsbruck, Austria
[3] Univ Hosp Zurich, Dept Diagnost & Intervent Radiol, Ramistr 100, CH-8091 Zurich, Switzerland
[4] Kantonsspital Winterthur, Dept Radiol & Nucl Med, Brauerstr 15, CH-8401 Winterthur, Switzerland
[5] GE Healthcare, 3000 N Grandview Blvd, Waukesha, WI 53188 USA
[6] Kantonsspital Baden, Dept Nucl Med, Ergel 1, CH-5404 Baden, Switzerland
[7] Univ Zurich, Ramistr 71, CH-8006 Zurich, Switzerland
关键词
Ga-68-PSMA-11; Positron-emission tomography; Magnetic resonance imaging; Radiation dosage; Pelvis; CLINICAL-EVALUATION; ALGORITHM; OSEM;
D O I
10.1007/s00330-020-06667-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives When increasing the PET acquisition time to match the longer MRI protocol in simultaneous PET/MR, the injected PET tracer dose can possibly be lowered to reduce radiation exposure. Moreover, applying new commercially available time-of-flight (TOF) block sequential regularized expectation maximization (BSREM)-based reconstruction algorithms could allow for further dose reductions. The purpose of this study was to find the minimal dose of the tracer targeting the prostate specific membrane antigen (Ga-68-PSMA-11) for a dedicated 15-min pelvic PET/MR scan that still matches the image quality of a reference 3-min scan at 100% (150 MBq) dose. Methods In this retrospective analysis, 25 patients were included. PET emission datasets were edited to simulate stepwise reductions of injected tracer dose. Reference TOF ordered subset expectation maximum (OSEM) and new TOF BSREM reconstructions were performed and differences in the resulting PET images were visually and quantitatively assessed. Results Visually, TOF BSREM reconstructions with relatively high regularization parameter (beta) values are preferred. Quantitatively, however, high beta-values result in lower lesion maximum standardized uptake values (SUVmax) compared to the reference. A beta-value of 550 was considered the optimal compromise for the lowest possible 10% dose reconstructions, resulting in comparable visual assessment and lesion SUVmax. Conclusions This study indicates that the injected Ga-68-PSMA-11 tracer dose for a standard 3-min PET scan can be reduced to approximately 10% (15 MBq) when the PET acquisition time is matched to the 15-min pelvic MRI protocol, and when reconstructed with TOF BSREM using beta = 550. This decreases the effective dose from 3.54 to 0.35 mSv.
引用
收藏
页码:3188 / 3197
页数:10
相关论文
共 30 条
[1]   Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET [J].
Ahn, Sangtae ;
Ross, Steven G. ;
Asma, Evren ;
Miao, Jun ;
Jin, Xiao ;
Cheng, Lishui ;
Wollenweber, Scott D. ;
Manjeshwar, Ravindra M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15) :5733-5751
[2]   Analysis of organ uniformity in low count density penalized likelihood PET images [J].
Asma, Evren ;
Manjeshwar, Ravindra .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :4426-4432
[3]  
Asma E, 2012, IEEE NUCL SCI CONF R, P4062
[4]  
Boellaard R, 2001, J NUCL MED, V42, P808
[5]   Current Image Acquisition Options in PET/MR [J].
Boellaard, Ronald ;
Quick, Harald H. .
SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (03) :192-200
[6]   NEMA NU 2-2007 performance characteristics of GE Signa integrated PET/MR for different PET isotopes [J].
Caribe, Paulo R. R. V. ;
Koole, M. ;
D'Asseler, Yves ;
Deller, Timothy W. ;
Van Laere, K. ;
Vandenberghe, S. .
EJNMMI PHYSICS, 2019, 6 (1)
[7]   Physics of pure and non-pure positron emitters for PET: a review and a discussion [J].
Conti, Maurizio ;
Eriksson, Lars .
EJNMMI PHYSICS, 2016, 3 (01)
[8]   Comparison between pelvic PSMA-PET/MR and whole-body PSMA-PET/CT for the initial evaluation of prostate cancer: a proof of concept study [J].
Domachevsky, Liran ;
Bernstine, Hanna ;
Goldberg, Natalia ;
Nidam, Meital ;
Catalano, Onofrio A. ;
Groshar, David .
EUROPEAN RADIOLOGY, 2020, 30 (01) :328-336
[9]   Simultaneous 68Ga-PSMA HBED-CC PET/MRI Improves the Localization of Primary Prostate Cancer [J].
Eiber, Matthias ;
Weirich, Gregor ;
Holzapfel, Konstantin ;
Souvatzoglou, Michael ;
Haller, Bernhard ;
Rauscher, Isabel ;
Beer, Ambros J. ;
Wester, Hans-Juergen ;
Gschwend, Juergen ;
Schwaiger, Markus ;
Maurer, Tobias .
EUROPEAN UROLOGY, 2016, 70 (05) :829-836
[10]   68Ga-PSMA PET/CT: Joint EANM and SNMMI procedure guideline for prostate cancer imaging: version 1.0 [J].
Fendler, Wolfgang P. ;
Eiber, Matthias ;
Beheshti, Mohsen ;
Bomanji, Jamshed ;
Ceci, Francesco ;
Cho, Steven ;
Giesel, Frederik ;
Haberkorn, Uwe ;
Hope, Thomas A. ;
Kopka, Klaus ;
Krause, Bernd J. ;
Mottaghy, Felix M. ;
Schoder, Heiko ;
Sunderland, John ;
Wan, Simon ;
Wester, Hans-Juergen ;
Fanti, Stefano ;
Herrmann, Ken .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (06) :1014-1024