Usability evaluation of order sets in a computerised provider order entry system

被引:23
作者
Chan, Julie [2 ]
Shojania, Kaveh G. [3 ]
Easty, Anthony C. [2 ]
Etchells, Edward E. [1 ,3 ,4 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Med, Informat Serv, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M4N 3M5, Canada
[3] Univ Toronto, Ctr Patient Safety, Toronto, ON M4N 3M5, Canada
[4] Sunnybrook Res Inst, CHSS, Toronto, ON, Canada
关键词
DECISION-SUPPORT; PATIENT SAFETY; CPOE; IMPLEMENTATION; TECHNOLOGY; EFFICIENCY; BENEFITS; ANATOMY;
D O I
10.1136/bmjqs.2010.050021
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Computerised provider order entry (CPOE) is an important patient safety intervention that has encountered significant barriers to implementation. The usability of a CPOE system plays a significant role in its acceptance. The authors conducted a heuristic evaluation of a CPOE order set system to uncover existing usability issues prior to implementation. Methods: A heuristic evaluation methodology was used to evaluate the usability of a CPOE test order set system. There are 10 heuristic principles, such as error prevention, to help users identify and recover from errors. Evaluators included a staff physician with extensive clinical experience, and three engineers with expertise in heuristic evaluation methodology. The results of the heuristic evaluation were used to create a user centred design prototype. Results: 92 unique heuristic violations were found for the CPOE test order set system, including 35 identified by the clinician and at least one engineer, and 57 of the 92 violations (62%) found only by the clinician. All evaluators identified at least one violation of each of the 10 usability heuristics in their analysis of the CPOE system. A user centred design prototype was created to demonstrate changes that could improve usability. Interpretation: The CPOE test order set system had many usability heuristic violations. Many violations were found by a clinician with knowledge of the heuristic evaluation process. Implementation of the CPOE system was deferred and a new user centred design prototype was developed for future study. The authors recommend conducting heuristic evaluations early in the process of designing, selecting and implementing CPOE systems.
引用
收藏
页码:932 / 940
页数:9
相关论文
共 35 条
[1]   A consensus statement on considerations for a successful CPOE implementation [J].
Ash, JS ;
Stavri, PZ ;
Kuperman, GJ .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2003, 10 (03) :229-234
[2]  
Baldauf-Sobez W., 2003, ELEKTROMEDICA, P2
[3]  
BATES DW, 1994, J AM MED INFORM ASSN, P996
[4]   Example of a Human Factors Engineering approach to a medication administration work system: Potential impact on patient safety [J].
Beuscart-Zephir, Marie-Catherine ;
Pelayo, Sylvia ;
Bernonville, Stephanie .
INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2010, 79 (04) :E43-E57
[5]  
Briggs B, 2003, HLTH DATA MANAG, V11, P50
[6]  
Briggs B, 2003, HLTH DATA MANAG, V11, P52
[7]  
Briggs Bill, 2003, Health Data Manag, V11, P44
[8]   Types of unintended consequences related to computerized provider order entry [J].
Campbell, Emily M. ;
Sittig, Dean F. ;
Ash, Joan S. ;
Guappone, Kenneth P. ;
Dykstra, Richard H. .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2006, 13 (05) :547-556
[9]   Does user-centred design affect the efficiency, usability and safety of CPOE order sets? [J].
Chan, Julie ;
Shojania, Kaveh G. ;
Easty, Anthony C. ;
Etchells, Edward E. .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2011, 18 (03) :276-281
[10]  
Chan Wendy, 2002, J Healthc Inf Manag, V16, P71