Novel robotic technology for the rapid intraoperative manufacture of patient-specific instrumentation allowing for improved glenoid component accuracy in shoulder arthroplasty: a cadaveric study

被引:12
作者
Darwood, Alastair [1 ]
Hurst, Simon A. [1 ,2 ]
Villatte, Guillaume [3 ]
Tatti, Fabio [1 ]
El Daou, Hadi [1 ]
Reilly, Peter [2 ]
Baena, Ferdinando Rodriguez Y. [1 ]
Majed, Addie [4 ]
Emery, Roger [2 ]
机构
[1] Imperial Coll, Dept Mech Engn, Fac Engn, South Kensington Campus, London SW7 2AZ, England
[2] Imperial Coll Healthcare NHS Trust, St Marys Hosp, London, England
[3] Ctr Hosp Clermont Ferrand, Clermont Ferrand, France
[4] Natl Orthopaed Hosp, Brockley Hill, Stanmore, Middx, England
关键词
Robotic; PSI; CAOS; navigation; computer-assisted surgery; arthroplasty; shoulder; SURGERY;
D O I
10.1016/j.jse.2021.08.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Accurate prosthesis placement in arthroplasty is an important factor in the long-term success of these interventions. Many types of guidance technology have been described to date often suffering from high costs, complex theater integration, time inefficiency, and problems with day-to-day usability. We present a novel, intraoperative robotics platform, capable of rapid, real-time manufacture of low-cost patient-specific guides while overcoming many of the issues with existing approaches. Methods: A prototype robotics platform was assessed in a 24-specimen cadaveric trial during sequential simulated shoulder arthroplasty procedures. The platform consisted of a tableside robot with sterile drapes and sterile disposable components. The robot itself comprised a 3D optical scanner, a 3-axis sterile robotic drill, and a 2-axis receptacle into which the disposable consumables were inserted. The consumable was composed of a region of rapidly setting moldable material and a clip allowing it to be reversibly attached to the robot. Computed tomographic (CT) imaging was obtained for all cadaveric specimens, and a surgical plan was created focusing on glenoid component positiondspecifically, guidewire position to allow for accurate glenoid preparation before implant insertion. Intraoperatively, for every specimen, the relevant osseous anatomy was exposed and humeral and glenoid preparation undertaken in the usual manner. The sterile disposable was used to create a mold of the joint surface. Once set, the mold was inserted into the robot and an optical scan of the surface was undertaken followed by automatic surface registration with the CT data and surgical plan. An automatic guide hole was subsequently drilled into the molded blank, which was removed from the robot and placed back into the patient, with the melded surface ensuring exact replacement. The guidewire was then driven through the guide hole in accordance with the preoperative plan. Results: The novel robotic platform achieved average angular accuracies of 1.9 degrees (standard deviation [SD] 1.3) version and 1.2 degrees (SD 0.7) inclination with positional accuracy of 1.1 mm (SD 0.7) compared to a preoperative plan. Discussion: We have described a novel robotics platform that is able to reliably produce patient-specific intraoperative guides to allow for accurate guidewire placement. Guidance is provided using a portable intraoperative device. The results suggest achieved accuracy levels may be equivalent to those seen in other existing guidance technologies; however, eventual in vivo trials and analysis is required. This technology has potential transferability to improve accuracy in other areas of arthroplasty. (C) 2021 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:561 / 570
页数:10
相关论文
共 14 条
  • [1] Cabarcas Brandon C, 2019, JSES Open Access, V3, P117, DOI 10.1016/j.jses.2019.07.002
  • [2] Does Accurate Anatomical Alignment Result in Better Function and Quality of Life? Comparing Conventional and Computer-Assisted Total Knee Arthroplasty
    Choong, Peter F.
    Dowsey, Michelle M.
    Stoney, James D.
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (04) : 560 - 569
  • [3] Darwood RS, 2016, J Med Robot Res, V1, DOI [10.1142/S2424905X16500057, DOI 10.1142/S2424905X16500057]
  • [4] Accuracy of Glenoid Component Placement in Total Shoulder Arthroplasty and Its Effect on Clinical and Radiological Outcome in a Retrospective, Longitudinal, Monocentric Open Study
    Gregory, Thomas M.
    Sankey, Andrew
    Augereau, Bernard
    Vandenbussche, Eric
    Amis, Andrew
    Emery, Roger
    Hansen, Ulrich
    [J]. PLOS ONE, 2013, 8 (10):
  • [5] Accuracy of 3-Dimensional Planning, Implant Templating, and Patient-Specific Instrumentation in Anatomic Total Shoulder Arthroplasty
    Iannotti, Joseph P.
    Walker, Kyle
    Rodriguez, Eric
    Patterson, Thomas E.
    Jun, Bong-Jae
    Ricchetti, Eric T.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (05) : 446 - 457
  • [6] Robotic surgery in trauma and orthopaedics A SYSTEMATIC REVIEW
    Karthik, K.
    Legate-Stone, T. Co
    Dasgupta, P.
    Tavakkolizadeh, A.
    Sinha, J.
    [J]. BONE & JOINT JOURNAL, 2015, 97B (03) : 292 - 299
  • [7] Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: A prospective-randomized clinical study
    Kircher, Joern
    Wiedemann, Markus
    Magosch, Petra
    Lichtenberg, Sven
    Habermeyer, Peter
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (04) : 515 - 520
  • [8] A review of rapid prototyped surgical guides for patient-specific total knee replacement
    Krishnan, S. P.
    Dawood, A.
    Richards, R.
    Henckel, J.
    Hart, A. J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 1457 - 1461
  • [9] Robotic systems in orthopaedic surgery
    Lang, J. E.
    Mannava, S.
    Floyd, A. J.
    Goddard, M. S.
    Smith, B. P.
    Mofidi, A.
    Seyler, T. M.
    Jinnah, R. H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (10): : 1296 - 1299
  • [10] Three-dimensional printing in surgery: a review of current surgical applications
    Malik, Hammad H.
    Darwood, Alastair R. J.
    Shaunak, Shalin
    Kulatilake, Priyantha
    El-Hilly, Abdulrahman A.
    Mulki, Omar
    Baskaradas, Aroon
    [J]. JOURNAL OF SURGICAL RESEARCH, 2015, 199 (02) : 512 - 522