Prevention of Alveolar Air Leakage after Video-Assisted Thoracic Surgery: Comparison of the Efficacy of Methods Involving the Use of Fibrin Glue

被引:35
作者
Kawai, Hideki [1 ]
Harada, Kenji [2 ]
Ohta, Hideki [1 ]
Tokushima, Takeshi [3 ]
Oka, Shiro [2 ]
机构
[1] Akita Red Cross Hosp, Dept Thorac Surg, Akita 0101495, Japan
[2] Chemoserotherapeut Res Inst, Kumamoto, Japan
[3] Matsue Med Ctr, Dept Surg, Natl Hosp Org, Matsue, Shimane, Japan
关键词
alveolar air leakage; video-assisted thoracic surgery; polyglycolic acid sheet; fibrin glue; SYNTHETIC SEALANT; TRIAL;
D O I
10.1055/s-0031-1293599
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of this study was to evaluate the appropriate condition of use of the fibrin glue plus polyglycolic acid (PGA) sheet combination to obtain the optimal sealing effect. Methods 126 consecutive patients underwent video-assisted thoracic surgery (VATS) were divided into groups as follows: fibrin glue sprayed on the PGA sheet placed over the pleural defect (Method I); fibrinogen and thrombin solutions sprayed separately on the PGA sheet soaked in thrombin and placed over the pleural defect after rubbing of fibrinogen solution on the area (Method II); fibrin glue sprayed on the PGA sheet placed over the pleural defect after rubbing of fibrinogen solution on the area (Method III). Method II and Method III were also examined in an animal model. Results Postoperative air leakage wasmore effectively prevented by Method III than by the other two methods (p < 0.05). In the experimental study, a significantly higher seal-breaking pressure was obtained for Method III than for Method II (p < 0.05). Conclusion Method III was the most effective for preventing alveolar air leakage.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 13 条
[1]   Fibrin glue in pulmonary resection: A prospective, randomized, blinded study [J].
Fabian, T ;
Federico, JA ;
Ponn, RB .
ANNALS OF THORACIC SURGERY, 2003, 75 (05) :1587-1592
[2]   Effective application of fibrin sealant using a spray device with a double-tube structure [J].
Fukunaga, N ;
Uchida, T ;
Kaetsu, H ;
Kawakami, K ;
Ishihara, Y ;
Funatsu, A .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 1998, 18 (05) :345-349
[3]  
Gika Masatoshi, 2007, Interact Cardiovasc Thorac Surg, V6, P12
[4]   VIDEO-ASSISTED MINITHORACOTOMY VERSUS MUSCLE-SPARING THORACOTOMY FOR PERFORMING LOBECTOMY [J].
GIUDICELLI, R ;
THOMAS, P ;
LONJON, T ;
RAGNI, J ;
MORATI, N ;
OTTOMANI, R ;
FUENTES, PA ;
NOIRCLERC, M .
ANNALS OF THORACIC SURGERY, 1994, 58 (03) :712-718
[5]   The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage [J].
Itano, Hideki .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (03) :457-460
[6]   Fibrin glue and bioabsorbable felt patch for intraoperative intractable air leaks [J].
Hideaki Miyamoto ;
Toshiroh Futagawa ;
Zumin Wang ;
Akio Yamazaki ;
Atsuo Morio ;
Satoshi Sonobe ;
Hiroshi Izumi ;
Yasuyuki Hosoda ;
Enjo Hata .
The Japanese Journal of Thoracic and Cardiovascular Surgery, 2003, 51 (6) :232-236
[7]   Improved techniques of applying fibrin glue in lung surgery [J].
Morikawa, T ;
Katoh, H .
EUROPEAN SURGICAL RESEARCH, 1999, 31 (02) :180-186
[8]   THE EFFECT OF FIBRIN GLUING TO SEAL BRONCHIAL AND ALVEOLAR LEAKAGES AFTER PULMONARY RESECTIONS AND DECORTICATIONS [J].
MOURITZEN, C ;
DROMER, M ;
KEINECKE, HO .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1993, 7 (02) :75-80
[9]   New technique for application of fibrin sealant: Rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes [J].
Nakajima, S ;
Fukuda, T ;
Hasue, M ;
Sengoku, Y ;
Haraoka, J ;
Uchida, T .
NEUROSURGERY, 2001, 49 (01) :117-123
[10]   Thoracoscopic lobectomy: Report on safety, discharge independence, pain, and chemotherapy tolerance [J].
Nicastri, Daniel G. ;
Wisnivesky, Juan P. ;
Litle, Virginia R. ;
Yun, Jaime ;
Chin, Cynthia ;
Dembitzer, Francine R. ;
Swanson, Scott J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (03) :642-647