A wearable solution for accurate step detection based on the direct measurement of the inter-foot distance

被引:21
作者
Bertuletti, Stefano [1 ,2 ]
Della Croce, Ugo [1 ,2 ]
Cereatti, Andrea [1 ]
机构
[1] Univ Sassari, Bioengn Unit, Dept Biomed Sci, Viale San Pietro 43-B, I-07100 Sassari, SS, Italy
[2] Interuniv Ctr Bioengn Human Neuromusculoskeletal, Sassari, SS, Italy
关键词
Gait analysis; Mobility assessment; Walking cycle; Stride; Proximity sensor; Distance sensor; SPATIOTEMPORAL PARAMETERS; PHYSICAL-ACTIVITY; INERTIAL SENSORS; GAIT; ADULTS;
D O I
10.1016/j.jbiomech.2018.12.039
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Accurate step detection is crucial for the estimation of gait spatio-temporal parameters. Although several step detection methods based on the use of inertial measurement units (IMUs) have been successfully proposed, they may not perform adequately when the foot is dragged while walking, when walking aids are used, or when walking at low speed. The aim of this study was to test an original step-detection method, the inter-foot distance step counter (IFOD), based on the direct measurement of the distance between feet. Gait data were recorded using a wearable prototype system (SWING2DS), which integrates an IMU and two time-of-flight distance sensors (DSs). The system was attached to the medial side of the right foot with one DS positioned close to the forefoot (FOREDs) and the other close to the rearfoot (REARDs). Sixteen healthy adults were asked to walk over ground for two minutes along a loop, including both rectilinear and curvilinear portions, during two experimental sessions. The accuracy of the IFOD step counter was assessed using a stereo-photogrammetric system as gold standard. The best performance was obtained for REARDs with an accuracy higher than 99.8% for the instrumented foot step and 88.8% for the non-instrumented foot step during both rectilinear and curvilinear walks. Key features of the IFOD step counter are that it is possible to detect both right and left steps by instrumenting one foot only and that it does not rely on foot impact dynamics. The IFOD step counter can be combined with existing IMU-based methods for increasing step-detection accuracy. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:274 / 277
页数:4
相关论文
共 15 条
[1]   Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes [J].
Aminian, K ;
Najafi, B ;
Büla, C ;
Leyvraz, PF ;
Robert, P .
JOURNAL OF BIOMECHANICS, 2002, 35 (05) :689-699
[2]   Estimation of spatio-temporal parameters of gait from magneto-inertial measurement units: multicenter validation among Parkinson, mildly cognitively impaired and healthy older adults [J].
Bertoli, Matilde ;
Cereatti, Andrea ;
Trojaniello, Diana ;
Avanzino, Laura ;
Pelosin, Elisa ;
Del Din, Silvia ;
Rochester, Lynn ;
Ginis, Pieter ;
Bekkers, Esther M. J. ;
Mirelman, Anat ;
Hausdorff, Jeffrey M. ;
Della Croce, Ugo .
BIOMEDICAL ENGINEERING ONLINE, 2018, 17
[3]   Static and Dynamic Accuracy of an Innovative Miniaturized Wearable Platform for Short Range Distance Measurements for Human Movement Applications [J].
Bertuletti, Stefano ;
Cereatti, Andrea ;
Comotti, Daniele ;
Caldara, Michele ;
Della Croce, Ugo .
SENSORS, 2017, 17 (07)
[4]   A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms [J].
Caldas, Rafael ;
Mundt, Marion ;
Potthast, Wolfgang ;
de Lima Neto, Fernando Buarque ;
Markert, Bernd .
GAIT & POSTURE, 2017, 57 :204-210
[5]   The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic Review [J].
Fong, Daniel Tik-Pui ;
Chan, Yue-Yan .
SENSORS, 2010, 10 (12) :11556-11565
[6]   Wearable inertial sensors for human movement analysis [J].
Iosa, Marco ;
Picerno, Pietro ;
Paolucci, Stefano ;
Morone, Giovanni .
EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (07) :641-659
[7]   Assessment of Physical Activity of Hospitalised Older Adults: A Systematic Review [J].
Lim, S. E. R. ;
Ibrahim, K. ;
Sayer, A. A. ;
Roberts, H. C. .
JOURNAL OF NUTRITION HEALTH & AGING, 2018, 22 (03) :377-386
[8]   Does an accelerometer accurately measure steps taken under controlled conditions in adults with mild multiple sclerosis? [J].
Motl, Robert W. ;
Snook, Erin M. ;
Agiovlasitis, Stamatis .
DISABILITY AND HEALTH JOURNAL, 2011, 4 (01) :52-57
[9]   Validation of a step detection Algorithm during straight Walking and turning in Patients with Parkinson's disease and older Adults Using an Inertial Measurement Unit at the Lower Back [J].
Pham, Minh H. ;
Elshehabi, Morad ;
Haertner, Linda ;
Del Din, Silvia ;
Srulijes, Karin ;
Heger, Tanja ;
Synofzik, Matthis ;
Hobert, Markus A. ;
Faber, Gert S. ;
Hansen, Clint ;
Salkovic, Dina ;
Ferreira, Joaquim J. ;
Berg, Daniela ;
Sanchez-Ferro, Alvaro ;
van Dieen, Jaap H. ;
Becker, Clemens ;
Rochester, Lynn ;
Schmidt, Gerhard ;
Maetzler, Walter .
FRONTIERS IN NEUROLOGY, 2017, 8
[10]   Accuracy of StepWatch™ and ActiGraph Accelerometers for Measuring Steps Taken among Persons with Multiple Sclerosis [J].
Sandroff, Brian M. ;
Motl, Robert W. ;
Pilutti, Lara A. ;
Learmonth, Yvonne C. ;
Ensari, Ipek ;
Dlugonski, Deirdre ;
Klaren, Rachel E. ;
Balantrapu, Swathi ;
Riskin, Barry J. .
PLOS ONE, 2014, 9 (04)