Sensitive immunoassay detection of multiple environmental chemicals on protein microarrays using DNA/dye conjugate as a fluorescent label

被引:15
作者
Fan, Ziyan [1 ]
Keum, Young Soo [2 ,3 ]
Li, Qing X. [2 ]
Shelver, Weilin L. [4 ]
Guo, Liang-Hong [1 ]
机构
[1] Chinese Acad Sci, State Key Lab Environm Chem & Ecotoxicol, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
[2] Univ Hawaii Manoa, Dept Mol Biosci & Bioengn, Honolulu, HI 96822 USA
[3] Konkuk Univ Korea, Coll Life & Environm Sci, Seoul 143701, South Korea
[4] USDA Agr Res Serv, Biosci Res Lab, Fargo, ND 58102 USA
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2012年 / 14卷 / 05期
基金
中国国家自然科学基金;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; POLYBROMINATED DIPHENYL ETHERS; BROMINATED FLAME RETARDANTS; ANTIBODY; PBDES; GENERATION; EXPOSURE; SERUM;
D O I
10.1039/c2em10956e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Indirect competitive immunoassays were developed on protein microarrays for the sensitive and simultaneous detection of multiple environmental chemicals in one sample. In this assay, a DNA/SYTOX Orange conjugate was employed as an antibody label to increase the fluorescence signal and sensitivity of the immunoassays. Epoxy-modified glass slides were selected as the substrate for the production of 4 x 4 coating antigen microarrays. With this signal-enhancing system, competition curves for 17 beta-estradiol (E2), benzo[a]pyrene (BaP) and 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) were obtained individually on the protein microarray. The IC50 and calculated limit of detection (LOD) are 0.32 mu g L-1 and 0.022 mu g L-1 for E2, 37.2 mu g L-1 and 24.5 mu g L-1 for BaP, and 31.6 mu g L-1 and 2.8 mu g L-1 for BDE-47, respectively. LOD of E2 is 14-fold lower than the value reported in a previous study using Cy3 labeled antibody (Du et al., Clin. Chem, 2005, 51, 368-375). The results of the microarray immunoassay were within 15% of chromatographic analysis for all three pollutants in spiked river water samples, thus verifying the immunoassay. Simultaneous detection of E2, BaP and BDE-47 in one sample was demonstrated. There was no cross-reaction in the immunoassay between these three environmental chemicals. These results suggest that microarray-based immunoassays with DNA/dye conjugate labels are useful tools for the rapid, sensitive, and high throughput screening of multiple environmental contaminants.
引用
收藏
页码:1345 / 1352
页数:8
相关论文
共 37 条
[1]   Immunoassay for Monitoring Environmental and Human Exposure to the Polybrominated Diphenyl Ether BDE-47 [J].
Ahn, Ki Chang ;
Gee, Shirley J. ;
Tsai, Hsing-Ju ;
Bennett, Deborah ;
Nishioka, Marcia G. ;
Blum, Arlene ;
Fishman, Elana ;
Hammock, Bruce D. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (20) :7784-7790
[2]   Next generation of protein microarray support materials:: Evaluation for protein and antibody microarray applications [J].
Angenendt, P ;
Glökler, J ;
Sobek, J ;
Lehrach, H ;
Cahill, DJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :97-104
[3]   Polybrominated diphenyl ethers (PBDEs) and bioaccumulative hydroxylated PBDE metabolites in young humans from Managua, Nicaragua [J].
Athanasiadou, Maria ;
Cuadra, Steven N. ;
Marsh, Goran ;
Bergman, Ake ;
Jakobsson, Kristina .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2008, 116 (03) :400-408
[4]   Development of fluorescent polymerization-based signal amplification for sensitive and non-enzymatic biodetection in antibody microarrays [J].
Avens, Heather J. ;
Bowman, Christopher N. .
ACTA BIOMATERIALIA, 2010, 6 (01) :83-89
[5]   Bioanalytical screening methods for dioxins and dioxin-like compounds - a review of bioassay/biomarker technology [J].
Behnisch, PA ;
Hosoe, K ;
Sakai, S .
ENVIRONMENT INTERNATIONAL, 2001, 27 (05) :413-439
[6]   Protein Microarrays: Novel Developments and Applications [J].
Berrade, Luis ;
Garcia, Angie E. ;
Camarero, Julio A. .
PHARMACEUTICAL RESEARCH, 2011, 28 (07) :1480-1499
[7]   Determination of brominated flame retardants, with emphasis on polybrominated diphenyl ethers (PBDEs) in environmental and human samples - a review [J].
Covaci, A ;
Voorspoels, S ;
de Boer, J .
ENVIRONMENT INTERNATIONAL, 2003, 29 (06) :735-756
[8]   Review of analytical methods for the determination of estrogens and progestogens in waste waters [J].
De López Aida M.J. ;
Barceló D. .
Fresenius' Journal of Analytical Chemistry, 2001, 371 (4) :437-447
[9]   Development of miniaturized competitive immunoassays on a protein chip as a screening tool for drugs [J].
Du, HW ;
Wu, MT ;
Yang, WP ;
Yuan, G ;
Sun, YM ;
Lu, Y ;
Zhao, S ;
Du, QY ;
Wang, F ;
Yan, S ;
Pan, M ;
Lu, Y ;
Wang, S ;
Cheng, J .
CLINICAL CHEMISTRY, 2005, 51 (02) :368-375
[10]   Disposable amperometric immunosensor for the detection of polycyclic aromatic hydrocarbons (PAHs) using screen-printed electrodes [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) :73-82