Transcarotid Transcatheter Aortic Valve Replacement General or Local Anesthesia

被引:70
作者
Debry, Nicolas [1 ,2 ]
Delhaye, Cedric [1 ,2 ]
Azmoun, Alexandre [3 ,4 ]
Ramadan, Ramzi [3 ,4 ]
Fradi, Sahbi [3 ,4 ]
Brenot, Philippe [3 ,4 ]
Sudre, Arnaud [1 ,2 ]
Moussa, Mouhamed Djahoum [1 ,2 ]
Tchetche, Didier [5 ]
Ghostine, Said [3 ,4 ]
Mylotte, Darren [6 ]
Modine, Thomas [1 ,2 ]
机构
[1] CHRU Lille, Inst Cardiopulm, Dept Cardiol, Heart Team, Lille, France
[2] CHRU Lille, Inst Cardiopulm, Cardiovasc Surg Dept, Heart Team, Lille, France
[3] Ctr Medicochirurg Marie Lannelongue CCML, Dept Cardiol, Heart Team, Le Plessis Robinson, France
[4] Ctr Medicochirurg Marie Lannelongue CCML, Cardiovasc Surg Dept, Heart Team, Le Plessis Robinson, France
[5] Clin Pasteur, Toulouse, France
[6] Galway Univ Hosp, Galway, Ireland
关键词
aortic stenosis; general anesthesia; local anesthesia; transcarotid access; transcatheter aortic valve replacement; COREVALVE REVALVING SYSTEM; CAROTID-ARTERY; SUBCLAVIAN APPROACH; CLINICAL-OUTCOMES; IMPLANTATION; ACCESS; SAFETY; FEASIBILITY; SEDATION; SURGERY;
D O I
10.1016/j.jcin.2016.08.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The study sought to assess the safety and efficacy of a minimally invasive strategy (MIS) (local anesthesia and conscious sedation) compared to general anesthesia (GA) among the largest published cohort of patients undergoing transcarotid transcatheter aortic valve replacement (TAVR). BACKGROUND Transcarotid TAVR has been shown to be feasible and safe. There is, however, no information pertaining to the mode anesthesia in these procedures. METHODS Between 2009 and 2014, 174 patients underwent transcarotid TAVR at 2 French centers. All patients were unsuitable for transfemoral TAVR due to severe peripheral vascular disease. An MIS was undertaken in 29.8% (n = 52) and GA in 70.1% (n = 122). One-year clinical outcomes were available in all patients and were described according to the Valve Academic Research Consortium-2 consensus. RESULTS Transcarotid vascular access and transcatheter valve deployment was successful in all cases. Thirty-day mortality was 7.4% (n = 13) and 1-year all-cause and cardiovascular mortality were 12.6% (n = 22) and 8.0% (n = 14), respectively. According to the type of anesthesia, there was no between group difference in 30-day mortality (GA 7.3% vs. MIS 7.6%; p = 0.94), 1-year mortality (GA 13.9% vs. MIS 9.6%; p = 0.43), 1-month clinical efficacy (GA 85.2% vs. MIS 94.2%; p = 0.09), and early safety (GA 77.8% vs. MIS 86.5%; p = 0.18). There were 10 (5.7%) periprocedural cerebrovascular events: 4 strokes (2.2%) and 6 transient ischemic attacks (3.4%) among those treated with GA. There was neither stroke nor transient ischemic attack in the MIS group (p < 0.001). CONCLUSIONS The transcarotid approach for TAVR is feasible using general or local anesthesia. A higher rate of perioperative strokes was observed with GA. (C) 2016 by the American College of Cardiology Foundation.
引用
收藏
页码:2113 / 2120
页数:8
相关论文
共 50 条
[41]   Transcatheter Aortic Valve Replacement: Recent Evidence from Pivotal Trials [J].
Carvajal, Tomas ;
Villablanca-Spinetto, Pedro ;
Augoustides, John G. T. ;
Morozowich, Steven T. ;
Shamoum, Fadi E. ;
Gutsche, Jacob T. ;
Ramakrishna, Harish .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (03) :831-840
[42]   Comparison of Transcarotid vs. Transfemoral Transcatheter Aortic Valve Implantation [J].
Watanabe, Masazumi ;
Takahashi, Shinya ;
Yamaoka, Hironori ;
Sueda, Taijiro ;
Piperata, Antonio ;
Zirphile, Xavier ;
Leroux, Lionel ;
Peltan, Julien ;
Labrousse, Louis .
CIRCULATION JOURNAL, 2018, 82 (10) :2518-2522
[43]   Patient Selection and Outcomes of Transfemoral Transcatheter Aortic Valve Replacement Performed with Monitored Anesthesia Care Versus General Anesthesia [J].
Pani, Saroj ;
Cagino, John ;
Feustel, Paul ;
Musuku, Sridhar Reddy ;
Raja, Asim ;
Bruno, Natalie ;
Ursillo, Christopher ;
Arunakul, Nathapong ;
Poulos, Constantine M. ;
Welljams-Dorof, Michael ;
Roberts, Kevin ;
Torosoff, Mikhail ;
Delago, Augustine .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (06) :2049-2054
[44]   Transcarotid Approach for Transcatheter Aortic Valve Replacement With the Sapien 3 Prosthesis A Multicenter French Registry [J].
Overtchouk, Pavel ;
Folliguet, Thierry ;
Pinaud, Frederic ;
Fouquet, Oliver ;
Pernot, Mathieu ;
Bonnet, Guillaume ;
Hubert, Maxime ;
Lapeze, Joel ;
Claudel, Jean Philippe ;
Ghostine, Said ;
Azmoun, Alexandre ;
Caussin, Christophe ;
Zannis, Konstantinos ;
Harmouche, Majid ;
Verhoye, Jean-Philippe ;
Lafont, Antoine ;
Chamandi, Chekrallah ;
Ruggieri, Vito Giovanni ;
Di Cesare, Alessandro ;
Leclercq, Florence ;
Gandet, Thomas ;
Modine, Thomas .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (05) :413-419
[45]   Transcarotid versus transfemoral transcatheter aortic valve replacement: A systematic review and meta-analysis [J].
Munguti, Cyrus ;
Ndunda, Paul M. ;
Abukar, Abdullah ;
Jawad, Mohammed Abdel ;
Vindhyal, Mohinder R. ;
Fanari, Zaher .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 68 :92-97
[46]   Transcarotid versus transthoracic access for transcatheter aortic valve replacement: A propensity-matched analysis [J].
Allen, Keith B. ;
Chhatriwalla, Adnan K. ;
Saxon, John ;
Hermiller, James ;
Heimansohn, David ;
Moainie, Sina ;
McKay, Raymond G. ;
Cheema, Mohiuddin ;
Jones, Brandon ;
Hodson, Robert W. ;
Korngold, Ethan ;
Kirker, Eric .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 164 (02) :506-515
[47]   Comparable Outcomes for Transcarotid and Transfemoral Transcatheter Aortic Valve Replacement at a High Volume US Center [J].
Jones, Brandon M. ;
Kumar, Vishesh ;
Chiu, Shih Ting ;
Korngold, Ethan ;
Hodson, Robert W. ;
Spinelli, Kateri J. ;
Kirker, Eric B. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2022, 34 (02) :467-474
[48]   Comparison of results of transcatheter femoral aortic valve replacement under local and general anesthesia A protocol for systematic review and meta-analysis [J].
Han, Xiangxiang ;
Liu, Shidong ;
Wang, Jialu ;
Chen, Hao ;
Chen, Yang ;
Song, Bing .
MEDICINE, 2021, 100 (34) :E27085
[49]   General Anesthesia Versus Local Anesthesia in Patients Undergoing Transcatheter Aortic Valve Replacement: An Updated Meta-Analysis and Systematic Review [J].
Ahmed, Adham ;
Mathew, Dave M. ;
Mathew, Serena M. ;
Awad, Ahmed K. ;
Varghese, Kathryn S. ;
Khaja, Sofia ;
Vega, Eamon ;
Pandey, Roshan ;
Thomas, Jeremiah J. ;
Mathew, Christopher S. ;
Ahmed, Sarah ;
George, Jerrin ;
Awad, Ayman K. ;
Fusco, Peter J. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (08) :1358-1367
[50]   Ketamine for Monitored Anesthesia Care During Transcatheter Aortic Valve Replacement [J].
Zhao, Chen B. ;
Yu, Jianjian ;
Kong, Maiying ;
Han, Jiange ;
Du, Hongyin ;
Huang, Jiapeng .
JOURNAL OF PERIANESTHESIA NURSING, 2022, 37 (02) :234-237